72V Vertical Motive Battery Pack Series (20S1P Pouch Cell Swapping Grade) | ATOMFAIRCOMMERCIAL GRADE · PRODUCTION
|
|||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
|
TAILORED SOLUTIONS FOR RESEARCH
Contact our engineering team for technical support or official institutional quotations.
EMAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
|||||||||||||||||||||||||||||||
The pack requires systematic BMS balancing to prevent premature layer degradation and must be charged only under authorized safety parameters. Terminal contacts must not be linked beyond designated load limits, and swapping lock alignment tolerances must be verified before locking.
- BMS Balancing Requirement: Systematic intelligent battery management balancing actions are required to block premature layer degradation loops.
- Terminal Contact Limit: Prevent terminal contacts from being linked past designated load limits to avoid electrical hazards.
- Charging Authorization: Execute charging loops exclusively under authorized safety parameters to prevent thermal runaway.
- Swapping Alignment Tolerance: Ensure swapping lock alignment tolerances line up properly before locking structural handles into the cabinet footprint.
Follow these steps to install the battery pack into a swapping cabinet and initiate charging. Proper alignment and connection are critical to avoid damage and ensure safety.
Required Equipment: Smart battery swapping cabinet, BMS communication interface (RS485 or CAN), Authorized charging system
- Inspect the pack
Inspect the battery pack for physical damage, swelling, or leakage before installation. - Align in cabinet
Align the pack vertically with the cabinet's sliding slots and push until the locking mechanism engages. - Verify lock alignment
Confirm the lock alignment tolerances are properly seated before securing the structural handles. - Connect communication
Connect the communication cables to the pack's RS485 or CAN port for telemetry data transmission. - Initiate charging
Initiate the charging cycle using only authorized safety parameters and monitor the BMS status.
What is the trade-off between the 2520 Wh and 3600 Wh variants in terms of physical dimensions and energy density for vertical swapping cabinets?
The 3600 Wh (50 Ah) variant delivers 43% more energy than the 2520 Wh (35 Ah) variant but requires a 30 mm taller enclosure (340 mm vs. 310 mm) and is 10 mm shorter in length (222 mm vs. 232 mm). Both share the same 72 V nominal potential and 20S1P topology, so the choice depends on whether the additional height fits the cabinet slot geometry and whether the extra range justifies the lower gravimetric energy density of the larger pouch stack.
Does this 72 V vertical battery pack support native communication with existing fleet management systems via CAN or RS485?
Yes, the integrated telemetry module natively supports Bluetooth (BT), RS485, and Controller Area Network (CAN) multi-protocol communication. This allows direct integration with corporate fleet management backends, PLC-controlled swapping stations, and cloud-based SOC/SOH monitoring systems without requiring external protocol converters.
What environmental protection rating does this battery pack have, and what operational precautions are required for safe swapping in automated cabinets?
The pack carries an IPX7 rating, meaning it withstands temporary immersion in water. For safe automated swapping, the operational compliance notice requires systematic intelligent BMS balancing to prevent premature layer degradation, prevention of terminal contact beyond designated load limits, and proper alignment of swapping lock tolerances before locking structural handles into the cabinet footprint.
This 72V vertical motive battery pack series (20S1P pouch cell swapping grade) is engineered for high-throughput urban battery swapping networks, offering two variants at 2520 Wh (35Ah) and 3600 Wh (50Ah) with a 72V nominal plateau. It features IPX7 hermetic sealing for flood/immersion resistance, over 2500 deep discharge cycles to 70% capacity, and multi-protocol BMS telemetry (Bluetooth, RS485, CAN) for fleet integration.
Positive
- Enhanced cycle durability: Rated for over 2500 deep discharge cycles to ≥70% capacity limits, significantly reducing long-term total cost of ownership for large urban fleets.
- IPX7 environmental protection: Industrial-grade hermetic shell sealing provides uncompromised safety against sudden flood immersion, heavy downpours, and high-humidity swap cabinets.
Trade-offs
- Requires intelligent BMS balancing: The high-capacity 72V vertical internal battery string requires systematic intelligent battery management balancing actions to block premature layer degradation loops.
- Handling and alignment constraints: Terminal contacts must not be linked past designated load limits, charging must be executed under authorized safety parameters, and swapping lock alignment tolerances must be properly aligned before locking into cabinet footprints.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).