Platinum Salt Bridge Counter Electrode 0.5×230mm ATOMFAIR®

$277.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

99.99% platinum wire counter electrode with integrated salt bridge, 0.5×230mm coil and 4mm spring diameter for RRDE electrochemistry. Order now.

SKU: AF-EC-E-PTSB-D050-L230
Category:
Brands:

Platinum wire counter electrode with salt bridge | ATOMFAIR

RESEARCH GRADE INSTRUMENT

Product Overview

The ATOMFAIR® Platinum Wire Counter Electrode with Salt Bridge is specifically designed for use with rotating ring-disk electrode systems. The electrode features a high-purity imported platinum wire (99.99% purity) formed into a coiled spring configuration with a wire diameter of 0.5mm, total length of 230mm, and a front-end spring diameter of 4mm, providing large specific surface area. The integrated salt bridge effectively prevents counter electrode precipitates or byproducts from migrating to and interfering with the working electrode during electrochemical experiments.

Technical Specifications

PARAMETER DETAILS
1. Core Device & Electrochemical Design
Electrode Geometry Cylindrical configuration
Salt Bridge Integrated design to isolate counter electrode byproducts
Compatible Systems Specifically designed for rotating ring-disk electrode systems
2. Electrode Material Portfolio Parameters
Material Coiled platinum wire
Purity 99.99%
Dimensions 0.5*230mm/4mm[Front-End Spring Diameter] (Available for other dimensions upon special request)


Key Features & Advantages

  • Integrated Salt Bridge Protection: Effectively isolates counter electrode reaction products and precipitates, preventing contamination or interference at the working electrode surface.
  • Large Specific Surface Area: Spring coil configuration (0.5mm x 230mm, 4mm spring diameter) provides significantly enhanced active surface area for improved current capacity.
  • Rotating Ring-Disk Electrode Compatibility: Specifically engineered to pair seamlessly with rotating disk electrode systems for hydrodynamic voltammetry applications.
  • High-Purity Imported Platinum: 99.99% purity ensures exceptional electrochemical cleanliness and highly reproducible experimental results.

APPLICATION SCOPE: Healthcare, Environmental Monitoring, Chemical Engineering, Bio-industry, and Advanced Energy Systems.
PACKAGING: Secure individual research-grade protective containers with shock-absorption parameters.
IMPORTANT NOTICE: This product is highly sensitive to surface contamination. Keep containers tightly sealed or handle exclusively within an anhydrous inert environment to prevent phase contamination or degradation before electrochemical validation.
TAILORED SOLUTIONS FOR RESEARCH
Contact our engineering team for technical support or official institutional quotations.
EMAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

This electrode is highly sensitive to surface contamination. Handle exclusively within an anhydrous inert environment to prevent degradation before electrochemical validation.

  • Surface Contamination Sensitivity: The platinum wire surface is highly sensitive to contamination, which can compromise electrochemical performance.
  • Inert Environment Requirement: Handling must occur exclusively within an anhydrous inert atmosphere to avoid phase contamination or degradation.
  • Sealed Storage Condition: Containers must remain tightly sealed until the electrode is prepared for use to maintain integrity.

How does the coiled spring configuration of the platinum wire counter electrode improve current capacity compared to a straight wire?

The coiled spring configuration (0.5mm diameter, 230mm total length, 4mm front-end spring diameter) provides a large specific surface area, which significantly enhances the active surface area for improved current capacity in electrochemical experiments. This design is specifically noted in the product specifications to offer enhanced current capacity.

How does the integrated salt bridge prevent counter electrode byproducts from interfering with the working electrode in rotating ring-disk electrode systems?

The integrated salt bridge effectively isolates counter electrode reaction products and precipitates, preventing their migration to and interference with the working electrode surface. This is a key design feature of the ATOMFAIR® Platinum Wire Counter Electrode, specifically engineered for use with rotating ring-disk electrode systems to maintain electrochemical cleanliness.

What handling and storage precautions are required to maintain the electrochemical cleanliness of the platinum wire counter electrode?

The product is highly sensitive to surface contamination, so containers must be kept tightly sealed or handled exclusively within an anhydrous inert environment to prevent phase contamination or degradation before electrochemical validation. This precaution is essential to preserve the 99.99% purity and ensure reproducible experimental results.

This 99.99% purity platinum wire counter electrode with integrated salt bridge and coiled spring design provides enhanced surface area for rotating ring-disk electrode systems, but requires strict handling to prevent surface contamination and is limited to RRDE-compatible setups.

Positive

  • Integrated Salt Bridge Protection: The integrated salt bridge isolates counter electrode byproducts and precipitates, preventing contamination or interference at the working electrode surface during electrochemical experiments.
  • Large Specific Surface Area Coil: The coiled spring configuration (0.5mm diameter, 230mm length, 4mm front-end spring diameter) provides significantly enhanced active surface area for improved current capacity in hydrodynamic voltammetry.

Trade-offs

  • Surface Contamination Sensitivity: The electrode is highly sensitive to surface contamination; containers must be kept tightly sealed or handled exclusively within an anhydrous inert environment to prevent phase contamination or degradation before electrochemical validation.
  • Requires RRDE System Compatibility: This electrode is specifically engineered for use with rotating ring-disk electrode systems, limiting its direct application to other electrochemical setups without adapter modifications.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).