Gas Diffusion Electrolysis Cell SLC 20×20 mm ATOMFAIR®

$1,080.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

AF-GDE-SLC gas diffusion electrolysis cell with single liquid chamber, serpentine gas channel and 20×20 mm channel size for research testing. Order now.

Single-Liquid-Chamber Gas Diffusion Electrolysis Cell

Product Type: Gas diffusion electrolysis cell
Research-grade laboratory product

Product Overview

Single-Liquid-Chamber Gas Diffusion Electrolysis Cell is a Gas diffusion electrolysis cell configured for research electrochemical workflows with the source-supported chamber, window, electrode and flow features listed below.

The Atomfair model AF-GDE-SLC is assigned for public catalog use. Quotation should confirm the selected configuration, required electrodes, membranes, windows and any customized dimensions before ordering.

Performance Features

  • Single-liquid-chamber gas diffusion cell for flow-phase electrochemical testing.
  • Serpentine channel is commonly used as the gas channel.
  • Gas passes through the gas diffusion layer to react with the chamber-side electrolyte.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-GDE-SLC
Liquid chamber Single liquid chamber
Electrochemical testing Flow-phase electrochemical testing
Chamber layout One chamber-type side and one serpentine-channel side
Channel size 20*20 mm
Electrodes Platinum mesh electrode and reference electrode purchased separately
PACKAGING: Standard protective packaging ensures safe delivery; custom reinforcement is available upon request.
ACCESSORY SELECTION: Confirm electrodes, membranes, windows, gas diffusion electrodes and other separately purchased items for the selected configuration.
CUSTOMIZATION: For non-standard electrode sizes or window materials, please specify requirements in your inquiry.
LABORATORY PROCUREMENT SUPPORT
For model selection, technical compatibility or configuration confirmation, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC LLC
Brand: ATOMFAIR®

This cell requires separately purchased electrodes, membranes, windows, and gas diffusion electrodes for operation. Proper component selection and configuration must be confirmed with the manufacturer to ensure safe and effective electrochemical testing.

  • Electrode Requirement: Platinum mesh and reference electrodes must be purchased separately and are not included with the cell.
  • Membrane and Window Selection: Membranes, windows, and gas diffusion electrodes must be selected based on the specific electrochemical application and confirmed during ordering.
  • Customization: Non-standard electrode sizes or window materials require specification in the inquiry for feasibility and quotation.

What is the active electrode area of the AF-GDE-SLC single-liquid-chamber gas diffusion electrolysis cell?

The active electrode area corresponds to the serpentine channel size of 20*20 mm (400 mm²). This is the region where the gas diffusion layer contacts the electrolyte for three-phase boundary reactions, as specified in the technical specifications.

Can the AF-GDE-SLC cell be used with non-platinum working electrodes or custom membrane electrode assemblies?

Yes, the cell is designed for flexible configuration: electrodes, membranes, windows, and gas diffusion electrodes are all purchased separately. The source explicitly states that customization for non-standard electrode sizes and window materials is available upon inquiry, allowing use with alternative electrode materials and custom MEA designs.

What external infrastructure is required to operate the AF-GDE-SLC cell under normal flow-phase testing conditions?

The cell requires external gas flow through the serpentine channel, liquid electrolyte circulation through the single chamber, and a potentiostat for electrochemical control. Electrodes, membranes, and gas diffusion electrodes are not included and must be sourced separately. No operational pressure or flow rate specifications are provided in the source, so users should design their gas and liquid handling systems based on standard laboratory safety practices.

A single-liquid-chamber gas diffusion electrolysis cell designed for flow-phase electrochemical testing, featuring a serpentine gas channel (20×20 mm) and requiring separately purchased electrodes.

Positive

  • Single-liquid-chamber simplifies electrolyte handling: The single-liquid-chamber configuration streamlines electrolyte management for flow-phase electrochemical testing, reducing system complexity compared to dual-chamber designs.
  • Serpentine channel ensures uniform gas distribution: The serpentine gas channel geometry promotes even gas flow across the gas diffusion layer, enhancing reaction uniformity at the electrode-electrolyte interface.

Trade-offs

  • Electrodes purchased separately: Platinum mesh and reference electrodes are not included with the cell, requiring additional procurement and compatibility verification before operation.
  • Custom dimensions require inquiry: Non-standard electrode sizes or window materials are not available off-the-shelf; users must submit customization requests, potentially extending lead times.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).