Research-grade glassy carbon working electrode with diameters 1-20 mm, head thickness <4 mm, and compatibility with electrochemistry, SEM, AFM. Order now.

Multifunctional Combination Glassy Carbon Working Electrode Series | ATOMFAIR

RESEARCH GRADE INSTRUMENT

Product Overview

The ATOMFAIR® Multifunctional Combination Glassy Carbon Working Electrode features a high-performance glassy carbon disk as the active sensing surface, offering a wide potential window, low background current, and excellent chemical inertness for demanding electrochemical applications. The electrode incorporates an embedded disk design with diameters available from 1mm to 20mm, accommodating diverse experimental scales from micro-electrode sensing to macro-electrode bulk electrolysis. The electrode head thickness is less than 4mm, enabling use as a standard working electrode for conventional electrochemical measurements as well as direct integration with scanning electron microscopy (SEM) or atomic force microscopy (AFM) systems. This dual-purpose design bridges bulk electrochemistry and high-resolution surface characterization, allowing researchers to correlate electrochemical performance with structural and topographical features on the identical electrode surface.

Technical Specifications

PARAMETER DETAILS
1. Core Device & Electrochemical Design
Electrode Geometry Modular detachable configuration
Electrode Head Thickness Less than 4mm
Compatible Techniques Conventional electrochemistry, SEM, AFM
2. Electrode Material Portfolio Parameters
Material Glassy Carbon
Diameter Options 1mm, 2mm, 3mm, 4mm, 5mm, 6mm, 7mm, 8mm, 9mm, 10mm, 15mm, 20mm

Key Features & Advantages

  • Correlative Electrochemical-Microscopic Analysis: Enables direct structural and topographical correlation with electrochemical data from the identical electrode location without sample transfer.

  • Ultra-Thin Head Profile: Electrode head thickness below 4mm ensures compatibility with the working distance and stage clearance requirements of most electron and probe microscopes.
  • Homogeneous Material Purity: Features an uncompromised structural configuration with highly uniform elemental distribution across the electrode surface matrix, ensuring reproducible electrochemical responses.
  • Robust Corrosion Protection: Gold-plated copper rod (1.5x15mm) delivers enhanced oxidation resistance and maintains stable conductivity over extended use.

  • Flexible Diameter Selection: Available in 12 standard sizes from 1mm to 20mm (1mm, 2mm, 3mm, 4mm, 5mm, 6mm, 7mm, 8mm, 9mm, 10mm, 15mm, 20mm) to accommodate diverse experimental scales from micro-electrolysis to bulk solution analysis.

APPLICATION SCOPE: Healthcare, Environmental Monitoring, Chemical Engineering, Bio-industry, and Advanced Energy Systems.
PACKAGING: Secure individual research-grade protective containers with shock-absorption parameters.
IMPORTANT NOTICE: This product is highly sensitive to surface contamination. Keep containers tightly sealed or handle exclusively within an anhydrous inert environment to prevent phase contamination or degradation before electrochemical validation.
TAILORED SOLUTIONS FOR RESEARCH
Contact our engineering team for technical support or official institutional quotations.
EMAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

The electrode surface is vulnerable to contamination from ambient moisture and particulates, necessitating storage in sealed containers and handling within an anhydrous inert environment. The ultra-thin head profile (less than 4 mm) requires careful mechanical handling to prevent damage when integrating with scanning electron or atomic force microscopy systems.

  • Surface Contamination Sensitivity: The glassy carbon disk must be kept free from organic and particulate contaminants to maintain electrochemical performance.
  • Storage Requirement: The electrode must be stored in its sealed protective container when not in use to prevent exposure to humidity.
  • Handling Environment: All handling should be performed within an anhydrous inert atmosphere to avoid phase contamination or degradation before electrochemical validation.
  • Mechanical Integrity: The electrode head thickness of less than 4 mm requires careful insertion and removal from microscope stages to avoid bending or scratching.
  • Connector Maintenance: The gold-plated copper rod connector should be kept clean and free from corrosion to ensure stable electrical contact.

How does the choice of glassy carbon working electrode diameter affect signal-to-noise ratio and detection limits between micro-electrode and macro-electrode electrochemical experiments?

Smaller diameters (e.g., 1–5 mm) are optimized for micro-electrode sensing with higher spatial resolution, while larger diameters (10–20 mm) provide higher total current for macro-electrode bulk electrolysis. The glassy carbon material offers a wide potential window and low background current across all diameters, making the primary trade-off between spatial resolution and current magnitude depending on the selected diameter.

What specific constraints must be considered when using this combination glassy carbon electrode for correlative electrochemical and scanning electron or atomic force microscopy analysis?

The electrode head thickness is less than 4 mm, ensuring compatibility with the working distance and stage clearance of most SEM and AFM systems. The design enables direct structural and topographical correlation from the identical electrode location without sample transfer, provided the electrode surface is maintained contamination-free as stated in the handling notice.

What are the required storage and handling conditions to prevent surface contamination of the glassy carbon electrode before electrochemical validation?

The electrode is highly sensitive to surface contamination and must be kept in tightly sealed containers or handled exclusively within an anhydrous inert environment to prevent degradation. Secure individual research-grade protective containers with shock-absorption parameters are provided for storage.

The ATOMFAIR Multifunctional Combination Glassy Carbon Working Electrode enables direct correlative electrochemical and microscopic analysis with its ultra-thin head profile, but requires stringent handling to avoid surface contamination.

Positive

  • Ultra-thin head for correlative microscopy: Electrode head thickness below 4 mm allows direct integration with SEM and AFM systems, enabling structural and topographical correlation with electrochemical data from the identical electrode surface without sample transfer.
  • Flexible diameter range for diverse scales: Available in 12 standard sizes from 1 mm to 20 mm, accommodating experimental scales from micro-electrolysis to bulk solution analysis.

Trade-offs

  • Surface contamination sensitivity: The glassy carbon surface is highly sensitive to contamination; containers must be tightly sealed or handled exclusively within an anhydrous inert environment to prevent degradation before electrochemical validation.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).

Electrode Diameter

1 mm, 2 mm, 3 mm, 4 mm, 5 mm, 6 mm, 7 mm, 8 mm, 9 mm, 10 mm, 15 mm, 20 mm