T-Shaped Cadmium Working Electrode 2mm Disk ATOMFAIR®

$71.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Research-grade T-shaped cadmium working electrode with 2mm embedded disk, PTFE body, and 1.5×15mm gold-plated copper rod for redox studies. Order now.

SKU: AF-EC-E-TSHA-SPEC-STD1
Category:
Tags: ,
Brands:

t-Shaped Cadmium Working Electrode series | ATOMFAIR

RESEARCH GRADE INSTRUMENT

Product Overview

The ATOMFAIR® T-Shaped Cadmium Working Electrode features a 2mm embedded cadmium disk. The electrode is equipped with a gold-plated copper rod (1.5x15mm) for enhanced corrosion resistance and stable conductivity. The rod body is manufactured from premium polytetrafluoroethylene (PTFE), offering excellent chemical inertness and thermal stability. This electrode is designed to deliver consistent, research-grade performance across a wide spectrum of electrochemical applications, with cadmium as the primary material providing unique electrochemical properties, excellent reproducibility, and specialized performance in specific redox systems and stripping voltammetry applications.

Technical Specifications

PARAMETER DETAILS
1. Core Device & Electrochemical Design
Electrode Geometry T-Type Cylindrical Configuration with flat embedded disk
Connector Rod Copper rod with gold-plated finish (1.5 x 15mm)
Insulative Body Polytetrafluoroethylene (PTFE)
2. Electrode Material Portfolio Parameters
Material Cadmium
Diameter Options 2mm

Key Features & Advantages

  • Specialized Cadmium Material: Constructed from high-grade cadmium, providing specific electrochemical characteristics suitable for targeted redox systems and specialized corrosion studies.
  • Precision Embedded Design: T-Shaped cylindrical geometry with standardized disk diameter promotes reproducible electrode placement and uniform current density distribution.

  • Robust Corrosion Protection: Gold-plated copper rod (1.5x15mm) delivers enhanced oxidation resistance and maintains stable conductivity over extended use.

  • Universal Compatibility: Designed with standard dimensions to ensure seamless integration with commercially available three-electrode cell systems and rotating disk electrode setups.

APPLICATION SCOPE: Healthcare, Environmental Monitoring, Chemical Engineering, Bio-industry, and Advanced Energy Systems.
PACKAGING: Secure individual research-grade protective containers with shock-absorption parameters.
IMPORTANT NOTICE: This product is highly sensitive to surface contamination. Keep containers tightly sealed or handle exclusively within an anhydrous inert environment to prevent phase contamination or degradation before electrochemical validation.
TAILORED SOLUTIONS FOR RESEARCH
Contact our engineering team for technical support or official institutional quotations.
EMAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

The electrode requires strict contamination control to maintain electrochemical performance. Storage and handling must occur in anhydrous inert environments to prevent surface degradation.

  • Surface Contamination Sensitivity: The electrode is highly sensitive to surface contamination and must be protected from exposure to ambient atmosphere.
  • Inert Environment Requirement: All handling must be performed exclusively within an anhydrous inert environment to prevent phase contamination.
  • Preventing Degradation: Proper storage and handling prevent degradation before electrochemical validation.

What performance trade-off does the gold-plated copper rod connector offer compared to a standard copper rod in electrochemical experiments?

The gold-plated copper rod (1.5x15mm) provides enhanced corrosion resistance and maintains stable conductivity over extended use, trading off higher manufacturing cost for long-term reliability in aggressive electrolyte environments. This design is especially beneficial for sustained electrochemical measurements where connector degradation could compromise signal integrity.

What types of electrochemical setups are compatible with the ATOMFAIR T-Shaped Cadmium Working Electrode?

The electrode is designed with standard dimensions for seamless integration with commercially available three-electrode cell systems and rotating disk electrode setups. Its T-shaped cylindrical geometry and flat embedded disk ensure reproducible placement and uniform current density across a broad range of electrochemical applications.

What specific storage and handling conditions are required to maintain the integrity of the cadmium working electrode before use?

The electrode is highly sensitive to surface contamination; it must be stored in tightly sealed containers or handled exclusively within an anhydrous inert environment to prevent phase contamination or degradation before electrochemical validation. The packaging includes secure individual research-grade protective containers with shock-absorption parameters to ensure safe transport and storage.

The T-Shaped Cadmium Working Electrode from ATOMFAIR offers a 2mm cadmium disk embedded in a PTFE body with gold-plated copper connector, providing specialized electrochemical properties for targeted redox systems and stripping voltammetry, but requires careful handling in inert conditions to avoid surface contamination.

Positive

  • Specialized Cadmium Electrochemical Properties: High-grade cadmium material provides unique electrochemical characteristics suitable for targeted redox systems, specialized corrosion studies, and stripping voltammetry applications.
  • Gold-Plated Rod for Corrosion Resistance: The 1.5x15mm gold-plated copper rod delivers enhanced oxidation resistance and maintains stable conductivity over extended use, ensuring reliable signal transmission.

Trade-offs

  • Surface Contamination Sensitivity: The electrode is highly sensitive to surface contamination; it must be stored in tightly sealed containers or handled exclusively within an anhydrous inert environment to prevent degradation before electrochemical validation.
  • Specialized Application Scope: Cadmium as the electrode material provides specific electrochemical characteristics limited to targeted redox systems and specialized corrosion studies, making it unsuitable for general-purpose electrochemical work.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).