304 Stainless Steel Working Electrode 3mm PTFE ATOMFAIR®

$44.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Research-grade 304 stainless steel working electrode with PTFE leak-proof encapsulation, 5 mm head length, and 3 mm standard disk for electrochemistry.

SKU: AF-EC-E-304S-SPEC-3MM3
Category:
Tags:
Brands:

Standard 304 Stainless Steel Working Electrode Series | ATOMFAIR

RESEARCH GRADE INSTRUMENT

Product Overview

The ATOMFAIR® Standard 304 Stainless Steel Working Electrode delivers exceptional cell-to-cell consistency and eliminates baseline variability for advanced electrochemical systems. Designed for researchers requiring 304 stainless steel-based electrode materials for electrochemical studies, this electrode platform provides reliable performance for corrosion research, materials characterization, and specific redox systems. Its universal design fits seamlessly into standard three-electrode cells and rotating disk electrode setups. Featuring a 1mm to 10mm diameter 304 stainless steel disk configuration, this working electrode offers a specialized solution for electrochemical applications where 304 stainless steel’s well-balanced corrosion resistance, good formability, and stable electrochemical response in a wide range of aqueous and mild acidic environments are required.

Technical Specifications

PARAMETER DETAILS
1. Core Device & Electrochemical Design
Electrode Geometry Straight / Cylindrical geometry
Encapsulation Material High-grade PTFE (PEEK optional) – Absolute leak-proof sealing, non-contaminating
Electrode Head Length 5mm (Standard production specification)
2. Electrode Material Portfolio Parameters
Material 304 stainless steel
Diameter Options 3mm (standard), 1-10mm (customized)

Key Features & Advantages

  • Specialized 304 Stainless Steel Material: Constructed from high-grade 304 stainless steel, offering excellent general corrosion resistance, good mechanical strength, and reliable electrochemical performance suitable for corrosion studies, materials research, environmental monitoring, and targeted redox systems.

  • PTFE Leak-Proof Encapsulation: Advanced PTFE jacket ensures absolutely no electrolyte seepage, maintaining baseline stability and protecting the electrode seal during long-term experiments.

  • Flexible Diameter Selection: Available in 1mm to 10mm diameter range, accommodating various experimental requirements and allowing researchers to select the optimal size for their specific application.

APPLICATION SCOPE: Healthcare, Environmental Monitoring, Chemical Engineering, Bio-industry, and Advanced Energy Systems.
PACKAGING: Secure individual research-grade protective containers with shock-absorption parameters.
IMPORTANT NOTICE: This product is highly sensitive to surface contamination. Keep containers tightly sealed or handle exclusively within an anhydrous inert environment to prevent phase contamination or degradation before electrochemical validation.
TAILORED SOLUTIONS FOR RESEARCH
Contact our engineering team for technical support or official institutional quotations.
EMAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

This electrode is highly sensitive to surface contamination and must be stored in sealed containers. Exposure to ambient atmosphere can cause phase contamination or degradation before electrochemical validation.

  • Surface Contamination Sensitivity: The electrode surface must be protected from contamination to maintain baseline stability.
  • Anhydrous Inert Environment Requirement: Handling and storage must be performed within an anhydrous inert atmosphere to prevent degradation.

Proper handling ensures the electrode surface remains uncontaminated and ready for electrochemical measurements. Storage and transfer must be performed under anhydrous inert conditions.

Required Equipment: Inert atmosphere glovebox, Sealed storage container

  1. Inspect
    Inspect the electrode surface for visible contamination or damage before initial use.
  2. Transfer
    Transfer the electrode to an anhydrous inert atmosphere glovebox for storage or preparation.
  3. Seal
    Seal the storage container immediately after use to prevent moisture and oxygen exposure.

What are the performance trade-offs between PTFE and optional PEEK encapsulation for the 304 stainless steel working electrode?

The standard PTFE encapsulation provides absolute leak-proof sealing and non-contaminating properties, ensuring baseline stability in aqueous and mild acidic environments. PEEK encapsulation is offered as an optional alternative, which typically offers higher mechanical strength and temperature tolerance but may have different chemical compatibility. The source does not provide comparative performance data, so selection should be based on specific experimental conditions such as solvent resistance or operating temperature.

Can the 304 stainless steel working electrode with 3mm diameter be integrated into a rotating disk electrode (RDE) setup, and what are the dimensional constraints?

Yes, the electrode is designed for universal compatibility with standard three-electrode cells and rotating disk electrode setups, as stated in the product overview. The 3mm diameter disk fits common RDE rotators, and the 5mm electrode head length is the standard production specification. The PTFE encapsulation ensures leak-free operation during rotation, preserving baseline stability. Researchers should verify that the head length matches their specific RDE shaft requirements.

What handling and storage procedures are essential to prevent surface contamination of the 304 stainless steel working electrode?

The product is highly sensitive to surface contamination; containers must be kept tightly sealed or the electrode handled exclusively within an anhydrous inert environment to prevent phase contamination or degradation before electrochemical validation, per the important notice. Routine polishing with appropriate abrasives is recommended to maintain a clean active surface. The PTFE encapsulation protects the seal but does not shield the disk surface from airborne or handling-induced contamination.

The ATOMFAIR Standard 304 Stainless Steel Working Electrode (3mm diameter) provides a reliable platform for electrochemical studies requiring 304 stainless steel, with leak-proof PTFE encapsulation ensuring baseline stability, but it requires careful handling to avoid surface contamination.

Positive

  • 304 Stainless Steel Material: Constructed from high-grade 304 stainless steel, offering excellent general corrosion resistance, good mechanical strength, and reliable electrochemical performance suitable for corrosion studies, materials research, environmental monitoring, and targeted redox systems.
  • PTFE Leak-Proof Encapsulation: Advanced PTFE jacket ensures absolutely no electrolyte seepage, maintaining baseline stability and protecting the electrode seal during long-term experiments.

Trade-offs

  • Surface Contamination Sensitivity: This product is highly sensitive to surface contamination; it must be kept in tightly sealed containers or handled exclusively within an anhydrous inert environment to prevent phase contamination or degradation before electrochemical validation.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).