SpinCore M 0408 Low-Speed Centrifuge 300-4000 ATOMFAIR®

$317.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Research-grade low-speed centrifuge with 300-4000 rpm speed range, 1900 × g RCF, Angle rotor 12 x 10 mL or 8 x 15 mL, LED display. Model AF-SPCENM0408. In stock.

SKU: AF-EI-C-CENF-04KR-M408
Category:
Tags: , ,
Brands:

SpinCore M 0408 Clinical Low-Speed Centrifuge, 300-4000 rpm, step 100 rpm

Product Type: Low-Speed Centrifuge
Research-grade laboratory product

Product Overview

Low-Speed Centrifuge with 300-4000 rpm, step 100 rpm, 1900 × g and Angle rotor 12 x 10 mL or 8 x 15 mL supports laboratory centrifugation, sample separation and tube-processing workflows.

The specification table keeps speed, RCF, rotor capacity, timing, motor, safety, power, dimensional and temperature data visible for configuration review.

Performance Features

  • Speed capability of 300-4000 rpm, step 100 rpm supports method-specific centrifugation.
  • Maximum RCF of 1900 × g supports force-based separation review.
  • Rotor capacity of Angle rotor 12 x 10 mL or 8 x 15 mL supports tube and throughput matching.
  • Listed timer, motor, safety, power and dimensional parameters support procurement and installation confirmation.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-SPCENM0408-300TO4000RPM
Speed range 300-4000 rpm, step 100 rpm
Maximum RCF 1900 × g
Speed accuracy ±100 rpm
Rotor capacity Angle rotor 12 x 10 mL or 8 x 15 mL
Running time 1-99 min, continuous operation
Display LED
Program storage Blood, urine and stool sample programs
Dimensions 286 x 367 x 227 mm
Weight 9.2 kg

Selection and Use Notes

  • Confirm rotor, adapter and tube compatibility before quotation.
  • Confirm speed, RCF, temperature requirement and sample-container format against the selected method.
PROCUREMENT CHECK: Confirm model, working range, compatibility, consumables and required configuration before quotation.
DOCUMENTATION REVIEW: Product specifications and configuration details are reviewed against laboratory use requirements.
ACCESSORY MATCHING: Compatible accessories, replacement parts and consumables can be matched according to the selected configuration.
RFQ NOTE: Include the required model, configuration and quantity when requesting quotation support.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, platform compatibility or configuration confirmation, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

Rotor, adapter, and tube compatibility must be confirmed before use to prevent mechanical failure. Operating parameters must be matched to the specific centrifugation method to ensure proper separation and sample integrity.

  • Rotor Compatibility Constraint: Confirm that the rotor, adapters, and tubes are compatible with the selected angle rotor capacity before operation.
  • Method Parameters Constraint: Verify that the speed, RCF, and temperature requirements match the centrifugation protocol to avoid sample damage.
  • Sample Container Constraint: Ensure the sample-container format matches the rotor tube specifications to prevent tube rupture.

Plan and confirm configuration and method parameters before operating the SpinCore M 0408 centrifuge. Ensuring compatibility and protocol matching is critical for safe and effective centrifugation.

Required Equipment: SpinCore M 0408 Clinical Low-Speed Centrifuge

  1. Confirm rotor and tube compatibility
    Confirm that the rotor, adapters, and tubes are compatible with the selected capacity before operation.
  2. Verify method parameters
    Verify that the speed, RCF, and sample-container format match the selected centrifugation protocol.

How does the ±100 rpm speed accuracy affect separation resolution compared to centrifuges with finer speed control?

The speed accuracy of ±100 rpm matches the step increment, so each set speed is within one step of the target. For low-speed protocols such as blood separation, this tolerance is typically acceptable. However, for methods requiring precise g-force tuning, the 100-rpm step may limit fine resolution. Support: speed accuracy ±100 rpm, step 100 rpm, max RCF 1900 × g.

Can the standard angle rotor accommodate 5 mL or 2 mL blood collection tubes without adapters?

No. The supplied angle rotor is designed exclusively for 10 mL and 15 mL tubes (12 × 10 mL or 8 × 15 mL). Smaller tube sizes would require optional adapters, which are not listed in the product description. Support: rotor capacity stated as Angle rotor 12 x 10 mL or 8 x 15 mL.

What are the power and electrical requirements for installing the M0408 centrifuge?

The product description does not specify voltage, frequency, or power consumption values. Electrical parameters are referenced in the specification table without numerical data. For accurate installation planning, contact the manufacturer or request a quotation with full power requirements. Support: spec table lists “power” but no values; description states “listed … power … parameters support procurement confirmation.”

The SpinCore M 0408 is a clinical low-speed centrifuge with a speed range of 300-4000 rpm (step 100 rpm) and maximum RCF of 1900 × g, featuring an angle rotor that accommodates 12 x 10 mL or 8 x 15 mL tubes. Its ±100 rpm speed accuracy and limited RCF constrain its application to low-force separations such as blood, urine, and stool sample processing.

Positive

  • Stepwise speed control from 300-4000 rpm: The 100 rpm step increments allow method-specific centrifugation protocols to be precisely replicated across runs.
  • Dual tube format angle rotor: The included angle rotor supports both 10 mL and 15 mL tubes (12 x 10 mL or 8 x 15 mL configurations), increasing sample throughput flexibility without requiring rotor changes.

Trade-offs

  • Low maximum RCF of 1900 × g: The maximum relative centrifugal force of 1900 × g limits the centrifuge to low-speed separations; it is not suitable for applications requiring higher g-force pelleting or subcellular fractionation.
  • Speed accuracy of ±100 rpm: The specified speed accuracy of ±100 rpm may be a constraint for protocols that demand tighter speed reproducibility, particularly at lower set points where the error is proportionally larger.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).