SpinCore M 0424 Clinical Low-Speed Centrifuge, 500-4000 rpm, step 100 rpmProduct Type: Low-Speed Centrifuge
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, platform compatibility or configuration confirmation, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
The centrifuge must be placed on a stable, level surface with adequate clearance for heat dissipation and vibration isolation. Electrical supply must match the rated voltage and frequency to prevent motor damage or safety interlock failure.
- Rotor and Tube Compatibility: Only use rotors and tubes explicitly rated for the selected speed and RCF to avoid mechanical failure or sample leakage.
- Load Balancing Requirement: Opposing tubes must be balanced by weight within the rotor's specified tolerance to prevent excessive vibration and bearing wear.
- Operational Temperature Range: Operate the centrifuge within an ambient temperature range of 15–30 °C to ensure consistent motor performance and electronic reliability.
This procedure covers initial setup, rotor installation, sample loading, and program selection for routine centrifugation. Follow each step sequentially to ensure safe operation and reproducible separation results.
Required Equipment: Approved rotor and tube set, Balance scale for tube weight matching
- Inspect the centrifuge chamber and rotor
Inspect the centrifuge chamber for debris or moisture and confirm the rotor is securely seated on the drive spindle. - Load and balance sample tubes
Load sample tubes into the rotor in symmetrical pairs, ensuring each pair is weight-balanced to within 0.1 g using a balance scale. - Close and lock the lid
Close the centrifuge lid firmly until the latch engages, confirming the safety interlock is activated. - Set speed, time, and program parameters
Set the desired speed (500–4000 rpm in 100 rpm increments), running time (1–99 min or continuous), and select a stored program if applicable via the LCD interface. - Start the centrifugation run
Press the start button to begin the run, monitoring the display for stable speed and timer countdown. - Wait for complete stop before opening lid
Wait for the rotor to come to a complete stop before releasing the lid lock to access samples.
How does the 100 rpm step size and ±100 rpm accuracy affect the reproducibility of RCF for low-speed cell separation protocols?
The step size of 100 rpm means the closest achievable speed to a target may be off by up to 50 rpm, and the accuracy of ±100 rpm adds additional uncertainty. At the maximum RCF of 2500 × g, this corresponds to approximately ±125 × g variability. For protocols requiring precise g-force, such as platelet-rich plasma preparation, this tolerance may be acceptable for clinical low-speed work but should be verified against method requirements.
What tube configurations are available for the M 0424 centrifuge, and are adapters provided for non-standard tube sizes?
The centrifuge offers swing rotors for 6 x 15 mL and 4 x 50 mL tubes, and angle rotors for 24 x 15 mL, 12 x 10 mL, or 8 x 15 mL tubes. The description does not mention adapter availability or compatibility with microtubes, vacutainers, or PCR strips. Adapter compatibility must be confirmed with the manufacturer before use.
What are the benchtop space and power requirements for installing the SpinCore M 0424 centrifuge in a clinical lab?
The centrifuge dimensions are 364 x 440 x 268 mm and it weighs 14.5 kg, requiring a standard benchtop area. The product description does not specify electrical power requirements, so standard lab power supply (e.g., 110-240 V, 50/60 Hz) is typical for this class of centrifuge, but users should confirm with the manufacturer for their region.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).





