SpinCore G 1616 RE Large-Capacity Refrigerated High-Speed Centrifuge, 300-16000 rpm, step 1 rpmProduct Type: Refrigerated Centrifuge
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, platform compatibility or configuration confirmation, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
The centrifuge requires a stable electrical supply and compatible rotors and sample containers. Operating temperature must be within the specified range to maintain performance and safety.
- Electrical Requirements: The centrifuge must be connected to a grounded power supply within 100-240V, 50/60Hz, capable of delivering 1050W.
- Temperature Range: Ambient operating temperature must be maintained between -20°C and 40°C to ensure proper refrigeration and motor function.
- Rotor Compatibility: Only use rotors, adapters, and tubes that are compatible with the centrifuge's maximum speed and RCF specifications.
- Sample Container Compatibility: Sample containers must be rated for the maximum RCF and temperature range of the selected rotor.
- Weight and Stability: The centrifuge weighs 90 kg and must be placed on a level, stable surface capable of supporting its weight.
Confirm rotor and sample container compatibility before loading. Set the desired speed, temperature, and timer parameters, then start the run after ensuring balanced loading.
Required Equipment: Centrifuge, Rotors, Adapters, Sample tubes
- Check Compatibility
Confirm that the rotor, adapters, and sample tubes are compatible with the selected method and the centrifuge's specifications. - Set Parameters
Set the speed, RCF, temperature, and timer parameters according to the method requirements. - Load and Start
Load the sample tubes into the rotor in a balanced configuration and start the centrifuge run.
What is the practical impact of the 9-stage acceleration and deceleration control on sample yield and run time in the SpinCore G 1616 RE centrifuge?
The 9 up / 9 down settings allow fine-tuning of rotor acceleration and deceleration profiles. Slower rates (lower numbers) reduce sample resuspension and preserve pellet integrity but increase total run time, while faster rates (higher numbers) shorten cycle time at the risk of disturbing loose pellets. This is supported by the specification listing 'Acceleration / deceleration: 9 up / 9 down'.
Which rotor and tube formats are compatible with the 4 x 400 mL capacity of the SpinCore G 1616 RE refrigerated centrifuge?
The maximum capacity of 4 x 400 mL indicates the centrifuge accommodates rotors designed for four 400 mL tubes or equivalent volumes. However, the product description does not list specific rotor part numbers or adapter types; users must confirm rotor, adapter, and tube compatibility directly with the manufacturer before quotation, as stated in the procurement notes.
What are the electrical and physical installation requirements for the SpinCore G 1616 RE centrifuge?
The centrifuge operates on 100-240 V, 50/60 Hz with a maximum power consumption of 1050 W, requiring a dedicated circuit for reliable operation. It weighs 90 kg and measures 623 x 640 x 375 mm, necessitating a stable, level bench or floor mount capable of supporting the weight. The noise level is ≤70 dB, which may require hearing protection in quiet environments. These specifications are directly from the technical specifications table.
The SpinCore G 1616 RE refrigerated centrifuge provides a wide speed range (300–16000 rpm in 1 rpm steps) and high RCF (28621 × g) with a large capacity of 4 × 400 mL, enabling precise, high-throughput separation of temperature-sensitive samples. Its heavy weight (90 kg) and power consumption (1050 W) require robust lab infrastructure and careful installation planning.
Positive
- Wide speed range with fine control: Speed adjustable from 300 to 16000 rpm in 1 rpm increments allows precise method-specific centrifugation protocols.
- Large capacity and high RCF: Maximum capacity of 4 x 400 mL and RCF up to 28621 × g enable high-throughput separation of substantial sample volumes.
Trade-offs
- Requires accessory compatibility verification: Rotor, adapter, and tube compatibility must be confirmed before use to ensure safe and effective operation.
- Significant weight and power requirements: At 90 kg and 1050 W power consumption, the unit requires a sturdy lab bench or floor placement and a dedicated electrical circuit.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).