SpinCore G 1616 Large-Capacity High-Speed Centrifuge, 300-16000 rpm, step 1 rpmProduct Type: High-Speed Centrifuge
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, platform compatibility or configuration confirmation, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
This high-speed centrifuge requires a stable, level surface and a dedicated electrical supply within the specified voltage range to prevent operational instability. The rotor must be properly balanced and loaded within the maximum capacity of 4 x 400 mL to avoid mechanical failure and potential injury.
- Electrical Supply Constraint: Connect the centrifuge to a power outlet that supplies 100-240 V, 50/60 Hz, and 650 W as specified.
- Rotor Capacity Constraint: Do not load the rotor beyond its maximum capacity of 4 x 400 mL to ensure safe operation.
- Rotor Balance Constraint: Balance the rotor by placing sample tubes of equal weight in opposite positions before starting the centrifuge.
- Lid Safety Constraint: Ensure the lid is securely closed and latched before initiating any centrifugation cycle.
- Atmospheric Constraint: Operate the centrifuge only in a non-flammable, non-explosive atmosphere to prevent ignition hazards.
This procedure covers the safe initialization and operation of the SpinCore G 1616 centrifuge for routine laboratory sample separation. Following these steps ensures proper rotor balance, electrical safety, and consistent centrifugation results.
Required Equipment: Rotor compatible with 4 x 400 mL tubes, Tubes and adapters matching the rotor, Balance scale or equal-mass tube pairs
- Inspect the centrifuge and rotor
Inspect the centrifuge chamber, rotor, and lid for any visible damage or debris before each use. - Place the centrifuge on a stable surface
Set the centrifuge on a level, vibration-free surface with adequate clearance around all sides for ventilation. - Connect the power supply
Plug the power cord into a grounded outlet that matches the specified voltage range of 100-240 V. - Load the rotor with balanced tubes
Load the rotor with tubes of equal mass placed in opposite positions to maintain balance during rotation. - Close and secure the lid
Close the centrifuge lid firmly and confirm that the latch engages to prevent accidental opening. - Set centrifugation parameters
Set the desired speed, time, and acceleration/deceleration profiles using the control panel. - Start the centrifugation cycle
Press the start button and monitor the run until the rotor comes to a complete stop before opening the lid.
How does the 1 rpm and 1 × g step resolution of the SpinCore G 1616 centrifuge affect the accuracy of sedimentation protocols compared to centrifuges with coarser control?
The SpinCore G 1616 offers speed control from 300 to 16000 rpm in 1 rpm increments and RCF control from 1 to 28621 × g in 1 × g increments, enabling precise method optimization. This step resolution supports fine-tuning of separation conditions for protocols that require exact centrifugal forces, enhancing reproducibility across runs.
Does the SpinCore G 1616 centrifuge require a dedicated power supply or specific voltage installation for operation?
The centrifuge operates on 100-240 V, 50/60 Hz, 650 W, which is compatible with standard laboratory power outlets worldwide. It does not require a dedicated power supply, but users should verify that the circuit can handle the 650 W load and that the centrifuge is properly grounded.
What are the noise level and physical installation requirements for the SpinCore G 1616 centrifuge?
The centrifuge operates at ≤70 dB noise level, which is typical for high-speed centrifuges and may require hearing protection in quiet lab environments. It weighs 70 kg and has dimensions 440 x 640 x 375 mm, so it requires a sturdy bench or floor stand and adequate clearance for ventilation and access.
The SpinCore G 1616 is a high-speed centrifuge offering a wide speed range (300-16000 rpm) with fine 1 rpm resolution and a maximum RCF of 28621 × g. Its 4×400 mL capacity and 100-program storage support high-throughput, reproducible centrifugation. However, it lacks integrated refrigeration and requires separate rotor/adapter selection, which must be accounted for in procurement.
Positive
- Fine speed control with 1 rpm steps: Speed range of 300-16000 rpm with 1 rpm increments and maximum RCF of 28621 × g with 1 × g steps enables precise, method-specific centrifugal force application.
- Large capacity and program storage: Maximum capacity of 4 x 400 mL combined with storage for 100 programs and 9 acceleration/deceleration profiles supports high-throughput, reproducible separation workflows.
Trade-offs
- No integrated refrigeration: The centrifuge does not include temperature control; heat-sensitive samples require external cooling or method adjustment to maintain thermal stability during operation.
- Separate rotor/adapter required: Rotor, adapter, and tube compatibility must be confirmed and sourced separately; the base unit does not include these components, adding procurement steps.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).