SpinCore 2012 S Compact Micro High-Speed Centrifuge, 300-15000 rpm, step 100 rpmProduct Type: High-Speed Centrifuge
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, platform compatibility or configuration confirmation, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
The centrifuge must be operated with the lid closed and door lock engaged to prevent rotor ejection. Over-speed and over-temperature protection circuits will automatically shut down the unit if thresholds are exceeded.
- Lid Lock Requirement: The centrifuge will not operate unless the lid is fully closed and the door lock is engaged.
- Over-speed Protection: The unit will automatically shut down if the rotor speed exceeds the maximum rated speed of 15000 rpm.
- Over-temperature Protection: The unit will automatically shut down if internal temperature exceeds safe operating limits.
Select an appropriate rotor and load microcentrifuge tubes symmetrically. Set the speed and run time, then close the lid and start the run.
- Select Rotor
Select a rotor compatible with the tube sizes (0.2/0.5/1.5/2 mL or PCR strips) and load the rotor symmetrically with balanced tubes. - Close Lid
Close the centrifuge lid and ensure the door lock engages to secure the rotor compartment. - Set Speed
Set the desired speed using the 100 rpm step increments within the 300-15000 rpm range. - Set Time
Set the run time between 30 seconds and 99 minutes using the LCD interface. - Start Run
Press start to begin centrifugation; the unit will automatically monitor status and shut down if over-speed or over-temperature conditions occur.
How does the 100 rpm step size affect the precision of centrifugation protocols compared to a 10 rpm step instrument?
The 100 rpm step size provides adequate resolution for routine microcentrifuge methods such as pelleting cells or precipitating nucleic acids, but may not allow the fine speed tuning required for rate-zonal or isopycnic separations that demand ±10 rpm precision. The SpinCore 2012 S offers a speed range of 300–15000 rpm in 100 rpm increments with a speed accuracy of ±20 rpm, which is typical for benchtop high-speed microcentrifuges.
Can this centrifuge accommodate 0.2 mL PCR tubes and what rotor configuration is needed?
Yes, the centrifuge supports 0.2 mL PCR tubes through a dedicated rotor capacity of 4 x 0.2 mL PCR strips. Additionally, the listed rotor capacities include 12 x 0.2/0.5/1.5/2 mL and 18 x 0.2/0.5/1.5/2 mL, which can also accommodate 0.2 mL tubes with appropriate adapters. Confirm tube and adapter compatibility with the specific rotor before use, as the source does not specify whether adapters are included.
What safety features and infrastructure requirements are critical for installing the SpinCore 2012 S in a shared laboratory?
The centrifuge includes a door lock, over-speed protection, over-temperature detection, and status diagnosis for safe operation. It requires a standard 100–240 V, 50/60 Hz power outlet with 70 W maximum draw, and operates at ≤55 dB noise level, making it suitable for benchtop use in open lab spaces. Dimensions are 272 x 260 x 154 mm with a weight of 6.2 kg, so no special ventilation or reinforced bench is needed.
The SpinCore 2012 S compact micro high-speed centrifuge offers a speed range of 300–15000 rpm with ±20 rpm accuracy and multiple rotor capacity options, making it suitable for routine microcentrifuge workflows. Its maximum RCF of 16520 × g and the requirement to manually verify rotor and tube compatibility are key operational considerations.
Positive
- Wide speed range with fine step control: Speed range of 300–15000 rpm in 100 rpm increments with ±20 rpm accuracy supports method-specific centrifugation protocols.
- Multiple rotor capacity options: Rotor accommodates 12×0.2/0.5/1.5/2 mL, 18×0.2/0.5/1.5/2 mL, 6×0.5/1.5/2 mL tubes, and 4×0.2 mL PCR strips, providing flexibility for various sample formats.
Trade-offs
- Maximum RCF limited to 16520 × g: The maximum relative centrifugal force of 16520 × g may be insufficient for protocols requiring higher g-forces, such as certain subcellular fractionation steps.
- Requires manual compatibility verification: Rotor, adapter, and tube compatibility must be confirmed before use, adding a procedural step to ensure safe and effective operation.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).