Polarographic Dissolved Oxygen Electrode 0-20 mg/L ATOMFAIR®

$105.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Polarographic dissolved oxygen electrode with 0-20 mg/L and 0-200% saturation range, 12 mm x 120 mm POM body, 8-core interface, refillable reference solution.

Description

IoniProbe DO 01 2 M H Polarographic dissolved oxygen electrode

Product Type: Electrochemistry Electrode
Research-grade laboratory product

Product Overview

Electrochemistry Electrode IoniProbe DO 01 2 M H Polarographic dissolved oxygen electrode supports Polarographic dissolved oxygen electrode with 0-20 mg/L, 0-200%, saturation and Diameter 12 mm x 120 mm in a POM body.

It is configured for electrochemistry meter workflows where electrode model, measurement medium, connector, reference solution and application fit must be checked before purchase.

Application: Routine aqueous solution and aquaculture. Interface: 8-core.

Performance Features

  • Electrode or accessory type: Polarographic dissolved oxygen electrode.
  • Measurement range: 0-20 mg/L, 0-200%, saturation.
  • Temperature compensation: 10K where listed in the product configuration; otherwise not included.
  • Interface: 8-core.
  • Electrode body: POM.
  • Reference solution: Refillable.
  • Application fit: Routine aqueous solution and aquaculture.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-IONPDO012MH
Electrode model IoniProbe DO 01 2 M H
Name Polarographic dissolved oxygen electrode
Electrode body POM
Cable length 1 m unless specified otherwise
Internal temperature compensation 10K where listed in the product configuration; otherwise not included
Interface 8-core
Reference solution Refillable
Specification Diameter 12 mm x 120 mm
Measurement range 0-20 mg/L, 0-200%, saturation
Application Routine aqueous solution and aquaculture

Selection and Use Notes

  • Confirm electrode model, connector, body material, cable length, reference solution and sample medium compatibility before quotation.
PROCUREMENT CHECK: Confirm model, working range, compatibility, consumables and required configuration before quotation.
DOCUMENTATION REVIEW: Product specifications and configuration details are reviewed against laboratory use requirements.
ACCESSORY MATCHING: Compatible accessories, replacement parts and consumables can be matched according to the selected configuration.
RFQ NOTE: Include the required model, configuration and quantity when requesting quotation support.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, platform compatibility or configuration confirmation, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

This electrode requires confirmation of electrode model, connector, body material, cable length, reference solution, and sample medium compatibility prior to use. The refillable reference solution must be regularly maintained, and temperature compensation is only available when the 10K thermistor is included in the configuration.

  • Compatibility Requirement: Sample medium compatibility with routine aqueous solutions and aquaculture must be verified before deployment to prevent sensor damage or inaccurate readings.
  • Reference Solution Maintenance: The refillable reference solution must be replenished periodically to maintain stable oxygen measurement performance.
  • Temperature Compensation Constraint: Internal temperature compensation via a 10K thermistor is only active when explicitly included in the product configuration; otherwise manual temperature correction is required.
  • Cable Length and Interface: The electrode is supplied with a 1-meter cable and an 8-core interface, which must match the meter's connector for proper signal transmission.

What is the practical trade-off between measuring dissolved oxygen in mg/L versus percent saturation with the IoniProbe DO 01 electrode?

The electrode supports both mg/L and percent saturation measurement modes, covering 0-20 mg/L and 0-200% saturation respectively. The choice depends on whether the application requires absolute concentration (mg/L) for regulatory reporting or relative saturation for biological oxygen demand assessment. The source does not specify accuracy or resolution differences, so trade-offs are limited to unit preference rather than performance.

Which electrochemistry meters are compatible with the IoniProbe DO 01 2 M H electrode's 8-core interface?

The electrode uses an 8-core interface as stated in the specifications, but no specific compatible meter models are listed in the product description. The procurement notes explicitly require confirmation of electrode model, connector, and platform compatibility before quotation. Users must verify that their meter accepts an 8-core polarographic DO input, as this is the sole compatibility constraint provided.

What are the temperature compensation and refillable reference solution requirements for reliable operation of this polarographic DO electrode?

Internal temperature compensation uses a 10K thermistor only if included in the product configuration; otherwise no temperature correction is provided. The reference solution is refillable, requiring periodic replenishment to maintain stable readings. The POM body and dimensions (12 mm x 120 mm) impose no special handling beyond standard electrode care, but users must confirm that the 8-core connector and cable length (1 m unless specified otherwise) suit their measurement setup.

This polarographic dissolved oxygen electrode offers refillable reference electrolyte and a 0-20 mg/L range suitable for routine aqueous and aquaculture applications. Its POM body provides durability, but temperature compensation is only available when explicitly configured, and the standard 1m cable may restrict positioning.

Positive

  • Refillable reference electrolyte: The electrode's reference solution is refillable, allowing users to replenish electrolyte and extend operational lifetime.
  • Polarographic sensing principle: Polarographic dissolved oxygen measurement provides stable, sensitive readings within 0-20 mg/L and 0-200% saturation ranges.

Trade-offs

  • Temperature compensation optional: Internal temperature compensation (10K) is only present when explicitly configured; otherwise the electrode lacks automatic temperature correction, requiring manual compensation or stable conditions.
  • Standard 1m cable length: Unless specified otherwise, the electrode is supplied with a 1 m cable, which may restrict placement flexibility in larger vessels or remote monitoring setups.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).