Conductivity Electrode 2010 T k=10 Glass Body ATOMFAIR®

$59.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Research-grade glass conductivity electrode, IoniProbe 2010 T, k=10, 1-2000 mS/cm; 12 mm × 120 mm body and 4-core interface for conductive samples. In stock.

Description

IoniProbe Conductivity 2010 T Conductivity electrode

Product Type: Electrochemistry Electrode
Research-grade laboratory product

Product Overview

Electrochemistry Electrode IoniProbe Conductivity 2010 T Conductivity electrode supports Conductivity electrode with k=10, 1-2000 mS/cm and Diameter 12 mm x 120 mm in a Glass body.

It is configured for electrochemistry meter workflows where electrode model, measurement medium, connector, reference solution and application fit must be checked before purchase.

Application: High-conductivity solution. Interface: 4-core.

Performance Features

  • Electrode or accessory type: Conductivity electrode.
  • Measurement range: k=10, 1-2000 mS/cm.
  • Temperature compensation: 10K where listed in the product configuration; otherwise not included.
  • Interface: 4-core.
  • Electrode body: Glass.
  • Reference solution: Not applicable.
  • Application fit: High-conductivity solution.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-IONPCONDUCTIVITY2010T
Electrode model IoniProbe Conductivity 2010 T
Name Conductivity electrode
Electrode body Glass
Cable length 1 m unless specified otherwise
Internal temperature compensation 10K where listed in the product configuration; otherwise not included
Interface 4-core
Reference solution Not applicable
Specification Diameter 12 mm x 120 mm
Measurement range k=10, 1-2000 mS/cm
Application High-conductivity solution

Selection and Use Notes

  • Confirm electrode model, connector, body material, cable length, reference solution and sample medium compatibility before quotation.
PROCUREMENT CHECK: Confirm model, working range, compatibility, consumables and required configuration before quotation.
DOCUMENTATION REVIEW: Product specifications and configuration details are reviewed against laboratory use requirements.
ACCESSORY MATCHING: Compatible accessories, replacement parts and consumables can be matched according to the selected configuration.
RFQ NOTE: Include the required model, configuration and quantity when requesting quotation support.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, platform compatibility or configuration confirmation, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

This electrode is designed for high-conductivity solutions with a measurement range of 1-2000 mS/cm. It requires confirmation of sample medium compatibility and optional temperature compensation configuration before use.

  • Sample Medium Compatibility: Confirm that the sample medium is chemically compatible with the glass body and does not exceed the specified conductivity range.
  • Temperature Compensation Configuration: Check if internal temperature compensation (10K) is included in the product configuration as it is not standard.
  • Interface Compatibility: Verify that the 4-core interface is compatible with the intended electrochemistry meter.

How does the k=10 cell constant affect measurement accuracy for solutions near the lower end of the 1-2000 mS/cm range?

The IoniProbe Conductivity 2010 T uses a k=10 cell constant optimized for high-conductivity solutions (1-2000 mS/cm). At the lower limit near 1 mS/cm, sensitivity and accuracy may be reduced compared to a lower k-cell constant electrode, as the source explicitly targets high-conductivity applications and does not provide low-range accuracy specifications.

What meter compatibility constraints exist for the 4-core interface of the IoniProbe Conductivity 2010 T?

The electrode features a 4-core interface, but the product description does not list compatible meter models. Procurement notes explicitly require users to confirm connector compatibility before purchase. The 4-core connection is a specific electrical configuration that may require a matching meter input or adapter, and no universal compatibility information is provided.

What handling and storage precautions are required for the glass body of this conductivity electrode?

The electrode body is glass (12 mm diameter x 120 mm), which is fragile and requires careful handling to avoid breakage from mechanical shock or dropping. The source does not specify a storage solution, but glass electrodes of this slender profile should be stored securely in a holder or protective sleeve to prevent damage and contamination.

The IoniProbe Conductivity 2010 T electrode with k=10 cell constant offers a wide measurement range of 1-2000 mS/cm for high-conductivity solutions, but requires careful selection of temperature compensation configuration and cautious handling due to its glass body.

Positive

  • Wide high-conductivity range: Supports measurement from 1 to 2000 mS/cm, making it suitable for concentrated electrolyte solutions and industrial process monitoring.
  • Robust glass body construction: Glass electrode body provides chemical resistance against a broad range of aqueous solutions, ensuring durability in laboratory high-conductivity applications.

Trade-offs

  • Conditional temperature compensation: Internal temperature compensation (10K) is only available when explicitly listed in the product configuration; otherwise the electrode lacks automatic temperature correction, requiring manual compensation or selection of the configured variant.
  • Glass body fragility: The glass electrode body is mechanically fragile and requires careful handling to avoid breakage; not recommended for portable or rough industrial environments without protective housing.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).