Conductivity Electrode 0–200 mS/cm 12×120mm BNC ATOMFAIR®

$46.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

IoniProbe Conductivity 201 electrode for routine aqueous solutions, 0–200.0 mS/cm range, 12×120 mm plastic body, 1 m cable and BNC interface. Order now.

Description

IoniProbe Conductivity 201 Conductivity electrode

Product Type: Electrochemistry Electrode
Research-grade laboratory product

Product Overview

Electrochemistry Electrode IoniProbe Conductivity 201 Conductivity electrode supports Conductivity electrode with 0-200.0 mS/cm and Diameter 12 mm x 120 mm in a Plastic body.

It is configured for electrochemistry meter workflows where electrode model, measurement medium, connector, reference solution and application fit must be checked before purchase.

Application: Routine aqueous solution. Interface: BNC.

Performance Features

  • Electrode or accessory type: Conductivity electrode.
  • Measurement range: 0-200.0 mS/cm.
  • Temperature compensation: 10K where listed in the product configuration; otherwise not included.
  • Interface: BNC.
  • Electrode body: Plastic.
  • Reference solution: Not applicable.
  • Application fit: Routine aqueous solution.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-IONPCONDUCTIVITY201
Electrode model IoniProbe Conductivity 201
Name Conductivity electrode
Electrode body Plastic
Cable length 1 m unless specified otherwise
Internal temperature compensation 10K where listed in the product configuration; otherwise not included
Interface BNC
Reference solution Not applicable
Specification Diameter 12 mm x 120 mm
Measurement range 0-200.0 mS/cm
Application Routine aqueous solution

Selection and Use Notes

  • Confirm electrode model, connector, body material, cable length, reference solution and sample medium compatibility before quotation.
PROCUREMENT CHECK: Confirm model, working range, compatibility, consumables and required configuration before quotation.
DOCUMENTATION REVIEW: Product specifications and configuration details are reviewed against laboratory use requirements.
ACCESSORY MATCHING: Compatible accessories, replacement parts and consumables can be matched according to the selected configuration.
RFQ NOTE: Include the required model, configuration and quantity when requesting quotation support.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, platform compatibility or configuration confirmation, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

This electrode is intended for routine aqueous solutions only. Verify compatibility with the measurement medium, connector, and reference solution before use.

  • Application Medium: Use only in routine aqueous solutions as specified.
  • Connector Compatibility: Ensure the BNC interface matches the meter's input connector.

Does the IoniProbe Conductivity 201 provide automatic temperature compensation, and how critical is it for conductivity measurements over a wide temperature range?

No, this configuration of the IoniProbe Conductivity 201 does not include automatic temperature compensation (10K is listed only where configured). Since conductivity readings are highly temperature-dependent, accurate measurements under non-isothermal conditions require an external compensation method or additional temperature probe.

Can the BNC interface of the IoniProbe Conductivity 201 be used with any pH meter, or is it specific to conductivity meters?

While the BNC connector is physically universal, this electrode is designed for conductivity measurements in routine aqueous solutions with a range of 0–200.0 mS/cm. Using it with a pH meter that does not support conductivity mode will produce incorrect readings, and the plastic body limits compatibility to aqueous samples only.

What are the cable length and body material specifications, and do they impose any constraints on sample positioning or chemical compatibility?

The cable length is 1 m and the electrode body is plastic. The 1 m cable may limit placement distance from the meter, and the plastic body restricts chemical compatibility to routine aqueous solutions; organic solvents and aggressive reagents should be avoided as the product is not specified for such samples.

The IoniProbe Conductivity 201 is a plastic-body conductivity electrode with a BNC interface and a measurement range of 0-200.0 mS/cm, designed for routine aqueous solutions. Its main trade-off is the conditional availability of temperature compensation and its restricted application scope.

Positive

  • Wide conductivity measurement range: Supports 0-200.0 mS/cm, covering a broad range of aqueous sample conductivities for routine laboratory applications.
  • Standard BNC interface and plastic body: BNC interface ensures compatibility with common electrochemistry meters; plastic body provides durable, low-maintenance construction for routine use.

Trade-offs

  • Temperature compensation feature not guaranteed: Internal temperature compensation (10K) is included only when explicitly listed in the product configuration; otherwise, measurements may lack automatic temperature correction, requiring manual compensation or controlled ambient conditions.
  • Application scope limited to routine aqueous solutions: The electrode is specified for routine aqueous solution use only; non-aqueous solvents, high-viscosity samples, or extreme pH environments may cause inaccurate readings or damage to the plastic body.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).