IoniProbe Chloride ISE 01 ISE chloride electrodeProduct Type: Electrochemistry Electrode
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, platform compatibility or configuration confirmation, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
Before use, confirm electrode model, connector, body material, cable length, and sample medium compatibility with the intended meter. The electrode is designed for routine aqueous chloride measurements within 10^-1 to 10^-6 mol/L, with temperature compensation only when included in the configuration.
- Electrode Compatibility: Confirm that the electrode model, connector (BNC), body material (POM), cable length, reference solution requirement, and sample medium are compatible with the intended meter and application before use.
- Measurement Range: The electrode is calibrated for chloride ion measurement within a range of 10^-1 to 10^-6 mol/L (19 ug/L to 1.9 g/L) in routine aqueous solutions.
- Temperature Compensation: If the product configuration includes internal temperature compensation (10K), it must be verified; otherwise, external temperature compensation is required.
- Application Limitation: The electrode is intended for routine aqueous solutions only and is not validated for non-aqueous or organic solvent systems.
- Body Material: The POM (polyoxymethylene) electrode body provides chemical resistance for typical aqueous solutions but should be checked against aggressive solvents or extreme pH conditions.
What is the lower detection limit of the IoniProbe Chloride ISE 01 and what factors affect accuracy at trace chloride levels?
The specified measurement range extends down to 10⁻⁶ mol/L (19 µg/L) for chloride ions. However, the product documentation does not provide a specific detection limit or accuracy data. In routine aqueous solutions, accuracy at trace levels may be influenced by ionic strength, pH, and interfering ions. For precise low-concentration measurements, calibration with standards and possibly ionic strength adjustment are recommended.
Does the IoniProbe Chloride ISE 01 require a separate reference electrode or is it a combination electrode?
The product is described as an ISE chloride electrode with a BNC connector and the reference solution is marked as 'not applicable'. This indicates that the electrode is likely of a solid-state or polymer membrane type that does not require a separate reference solution. However, the source does not explicitly state whether it is a combination electrode. For practical use, it typically operates as a stand-alone sensing electrode that would require a separate reference electrode unless the meter provides a reference input. Users should confirm the meter's configuration.
What temperature compensation is included with the IoniProbe Chloride ISE 01 and do I need an external temperature probe?
The electrode includes internal temperature compensation (10K) only when specifically listed in the product configuration; by default it is not included. This means that for accurate measurements across varying temperatures, an external temperature probe or a meter with automatic temperature compensation (ATC) may be necessary. The product manual or configuration details should be checked before use.
The IoniProbe Chloride ISE 01 is a solid-state chloride ion-selective electrode with a POM body, BNC connector, and a wide measurement range from 10^-1 to 10^-6 mol/L. It is suited for routine aqueous chloride analysis but requires careful consideration of temperature compensation options and the need for a separate reference electrode.
Positive
- Wide chloride detection range: Covers 10^-1 to 10^-6 mol/L (19 µg/L to 1.9 g/L), spanning five orders of magnitude for trace to high-concentration chloride analysis in routine aqueous solutions.
- Chemically resistant POM body: Polyoxymethylene construction offers good chemical resistance and mechanical durability for routine laboratory use.
Trade-offs
- Temperature compensation conditionally available: Internal 10K temperature compensation is only included if specified in the product configuration; otherwise manual correction or external temperature measurement is required.
- Requires separate reference electrode: This is a sensing-only ISE electrode with no reference solution, so it must be paired with a compatible reference electrode and meter for complete electrochemical measurements.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).