IoniSense Conductivity DO 100 T Touch Screen Benchtop Electrochemistry MeterProduct Type: Touch Screen Benchtop Electrochemistry Meter
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, platform compatibility or configuration confirmation, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
The instrument must be used with a compatible conductivity electrode and standard solutions for accurate measurements. The measurement parameter, range, and calibration settings must be confirmed before operation to ensure proper configuration.
- Electrode and probe compatibility: The instrument must be configured with a compatible conductivity electrode (IoniProbe Conductivity 201 TG or 201 T) that matches the intended measurement parameter and range.
- Calibration requirement: A 1-point calibration using conductivity standard solutions is required before measurement to ensure the specified accuracy of ±0.5% FS.
- Temperature compensation setup: The user must set the temperature compensation range to match the sample temperature within 0-50°C for compensated conductivity readings.
- Configuration verification: The measurement parameter, range, accuracy, and consumables must be verified against the laboratory requirements before use to avoid incorrect measurements.
- Power supply safety: The instrument operates on DC12V power and should be used in a dry environment to prevent electrical hazards.
What is the effect of the single-point conductivity calibration on measurement accuracy across the automatic subranges?
The meter uses a single-point calibration for conductivity, which is suitable for routine measurements when sample conductivity is close to the calibration standard. The automatic segmentation divides the 0-200 mS/cm range into five subranges, and the specified accuracy of ±0.5% FS ±1 digit applies across the full range. However, single-point calibration cannot correct for nonlinearity between subranges, so users should verify accuracy within their specific measurement subrange after calibration.
Does the IoniSense Conductivity DO 100 T meter measure dissolved oxygen, and can it accept a DO probe?
No, the source lists only Conductivity, TDS, salinity, resistivity, and temperature as measured parameters. The standard package includes a conductivity electrode, not a dissolved oxygen probe. The meter is not designed for DO measurement, despite the 'DO' in the model name.
What power and environmental conditions are required for the IoniSense Conductivity DO 100 T benchtop meter?
The meter requires a DC12V power supply, which is included. It is a benchtop instrument intended for laboratory use. The temperature compensation range is 0.0-50.0°C, while the instrument can measure temperature from -10.0 to 135.0°C. The package includes a magnetic stirrer, indicating that samples should be stirred during measurement for consistency.
The IoniSense Conductivity DO 100 T is a touch-screen benchtop meter supporting conductivity, TDS, salinity, resistivity, and temperature measurements with a wide conductivity range (0–200 mS/cm) and automatic range segmentation. Its single-point conductivity calibration and requirement for manual electrode configuration impose operational constraints that must be matched to the intended application.
Positive
- Multi-parameter electrochemistry measurement: Measures conductivity, TDS, salinity, resistivity, and temperature, enabling versatile water quality analysis in a single benchtop instrument.
- Wide range with automatic segmentation: Conductivity range spans 0–200 mS/cm with automatic segmentation across six sub-ranges, providing flexibility for low to high concentration samples.
Trade-offs
- Single-point conductivity calibration: Only one calibration point is available for conductivity, which may reduce accuracy across the full measurement range compared to multi-point calibration.
- Electrode compatibility must be pre-confirmed: The instrument requires selection of the correct electrode or probe configuration before use, adding a procurement step and limiting immediate plug-and-play deployment.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.