IoniSense DO 100 T Touch Screen Benchtop Electrochemistry MeterProduct Type: Touch Screen Benchtop Electrochemistry Meter
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, platform compatibility or configuration confirmation, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
This instrument requires configurable compensation settings for temperature, salinity, and atmospheric pressure to ensure accurate dissolved oxygen readings. The polarographic or optical electrode must be selected and verified for compatibility with the intended measurement range and application.
- Calibration Requirement: Calibration must be performed with appropriate standards before each use or after electrode replacement.
- Compensation Settings: Automatic air pressure compensation and manual salinity compensation must be set to match the sample conditions.
- Electrode Compatibility: Only IoniProbe DO 01 2M polarographic or optical electrodes are compatible with this meter.
What is the effective operating temperature range for accurate dissolved oxygen measurements on the IoniSense DO 100 T?
The DO temperature compensation range is 0.0-50.0 °C, while the instrument measures temperature from -10.0 to 135.0 °C. For accurate dissolved oxygen readings, the sample temperature should be within the compensation range of 0.0-50.0 °C. The meter also automatically compensates for air pressure from 0 to 200.0 kPa.
What data output interfaces does the IoniSense DO 100 T support for integration with laboratory data systems?
The IoniSense DO 100 T supports USB, PC, and printer data output. It is powered by DC12V. The instrument is intended for electrochemical measurement workflows such as water quality screening, environmental sampling, aquaculture, education, and laboratory verification.
What power supply infrastructure is required for the IoniSense DO 100 T benchtop meter?
The instrument requires a DC12V power supply. A power adapter is included in the standard package. The meter is designed for benchtop use and should be operated with appropriate power access per laboratory or field requirements.
The IoniSense DO 100 T provides automated air pressure and temperature compensation for dissolved oxygen measurements with support for both polarographic and optical electrode types, but requires manual salinity input and has a DO temperature compensation ceiling of 50°C.
Positive
- Dual electrode type compatibility: Supports polarographic or optical dissolved oxygen electrodes via model selection, enabling users to choose based on maintenance preferences or application requirements.
- Automated environmental compensation: Automatic air pressure compensation and temperature compensation for DO reduce manual adjustments and improve measurement accuracy under varying field or lab conditions.
Trade-offs
- Manual salinity compensation required: Salinity compensation is user-entered (0-45 ppt), which introduces a manual step and potential for inaccuracy if not correctly set.
- Limited DO temperature compensation range: Temperature compensation for dissolved oxygen is only specified up to 50.0°C, restricting accurate compensated measurements above this temperature even though the instrument can measure temperature up to 135°C.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.