IoniSense Conductivity 100 T Touchscreen Meter ATOMFAIR®

$415.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Research-grade IoniSense Conductivity 100 T touchscreen benchtop meter for conductivity, TDS, salinity and resistivity. 0-200.0 mS/cm, -10.0-135.0 °C.

Description

IoniSense Conductivity 100 T Touch Screen Benchtop Electrochemistry Meter

Product Type: Touch Screen Benchtop Electrochemistry Meter
Research-grade laboratory product

Product Overview

Touch Screen Benchtop Electrochemistry Meter IoniSense Conductivity 100 T Touch Screen Benchtop Electrochemistry Meter supports Conductivity / TDS / salinity / resistivity / °C and (-10.0-135.0) °C / (14.0-275.0) °F.

The instrument is intended for electrochemical measurement workflows such as water quality screening, environmental sampling, aquaculture, education, process checks and laboratory verification when those applications match the selected measurement parameter.

Confirm the required measurement parameter, electrode or probe configuration and operating range before quotation.

Performance Features

  • Measurement parameter: Conductivity / TDS / salinity / resistivity / °C.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-IONSCONDUCTIVITY100T
Model IoniSense Conductivity 100 T
Measurement parameters Conductivity / TDS / salinity / resistivity / °C
Conductivity range 0-200.0 mS/cm, automatic segmentation: 0-19.99 µS/cm; 20.0-199.9 µS/cm; 200-1999 µS/cm; 2.00-19.99 mS/cm; 20.00-199.9 mS/cm; TDS: 0-100.0 g/L; resistivity: 5.00 Ω·cm-100.0 MΩ·cm; salinity: 0-100 ppt
Conductivity calibration points 1 point
Conductivity resolution 0.001
Conductivity temperature compensation (0.0-50.0) °C / (32.0-122.0) °F
Conductivity accuracy ±0.5% FS ±1 digit
Temperature range (-10.0-135.0) °C / (14.0-275.0) °F
Temperature accuracy ±0.2 °C
Data output USB / PC / printer
Power supply DC12V
Standard package Instrument; IoniProbe Conductivity 201 TG or IoniProbe Conductivity 201 T conductivity electrode; conductivity standard solutions; universal electrode holder; magnetic stirrer; power adapter

Selection and Use Notes

  • Confirm measurement parameter, range, accuracy, calibration requirement, temperature compensation and compatible electrode or probe before quotation.
PROCUREMENT CHECK: Confirm model, working range, compatibility, consumables and required configuration before quotation.
DOCUMENTATION REVIEW: Product specifications and configuration details are reviewed against laboratory use requirements.
ACCESSORY MATCHING: Compatible accessories, replacement parts and consumables can be matched according to the selected configuration.
RFQ NOTE: Include the required model, configuration and quantity when requesting quotation support.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, platform compatibility or configuration confirmation, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

This instrument requires calibration at one point using certified conductivity standard solutions. Temperature compensation is automatically applied within the range 0.0-50.0 °C.

  • Calibration requirement: The meter must be calibrated with a single standard solution before each measurement session to ensure accuracy.
  • Electrode compatibility: Only the specified IoniProbe Conductivity 201 TG or 201 T electrode or an equivalent with matching connector and temperature sensor should be used.
  • Power supply constraints: The instrument is powered by a DC12V adapter and must not be used with alternate power sources.
  • Measurement range autosegmentation: The conductivity range is automatically segmented into five sub-ranges to optimize resolution across 0-200.0 mS/cm.
  • Data output interface: Measurement data can be exported via USB to a PC or printer for documentation.

This procedure describes the calibration and measurement workflow for the IoniSense Conductivity 100 T. Follow these steps to obtain accurate readings.

Required Equipment: IoniSense Conductivity 100 T meter, IoniProbe conductivity electrode, Conductivity standard solution, Magnetic stirrer

  1. Connect electrode
    Attach the IoniProbe conductivity electrode to the meter's input port and secure the connection.
  2. Calibrate
    Immerse the electrode in the conductivity standard solution, stir gently, and initiate the one-point calibration routine.
  3. Measure sample
    Rinse the electrode with deionized water, immerse it in the sample, and record the displayed conductivity value after stabilization.
  4. Export data
    Connect the meter to a PC or printer via USB to transfer logged measurements for further analysis.

How does the single-point calibration affect accuracy across the conductivity meter's automatic segmentation ranges?

The IoniSense Conductivity 100 T uses a single-point calibration (1 point) for its entire conductivity range of 0–200.0 mS/cm, which is divided into six automatic segments (e.g., 0–19.99 µS/cm, 20.0–199.9 µS/cm, etc.). The stated accuracy is ±0.5% FS ±1 digit, so calibration at a single point may not compensate for non-linearities across extremely different measurement ranges. For best results, calibrate at a conductivity value representative of the expected sample. No multi-point calibration option is indicated in the source.

Which electrodes are compatible with the Conductivity 100 T meter, and what are the limitations for temperature compensation?

The standard package includes either the IoniProbe Conductivity 201 TG or IoniProbe Conductivity 201 T conductivity electrode. The meter's temperature compensation range is (0.0–50.0) °C / (32.0–122.0) °F, and the electrode's own temperature rating may differ. The source does not specify the electrode's cell constant or maximum temperature, so users must confirm the electrode matches the application and operating temperature before purchase.

What are the power and accessory requirements for setting up the IoniSense Conductivity 100 T in a laboratory?

The meter requires a DC12V power supply, which is included in the standard package. The package also contains the instrument, a conductivity electrode, conductivity standard solutions, a universal electrode holder, and a magnetic stirrer. No specific storage conditions are provided in the source, but as a benchtop electrochemistry meter, it should be kept in a clean, dry environment. Ensure the laboratory has a standard DC12V outlet or use the included adapter.

The IoniSense Conductivity 100 T is a benchtop electrochemistry meter supporting conductivity, TDS, salinity, resistivity, and temperature measurements with automatic range segmentation up to 200 mS/cm, suitable for water quality screening and laboratory verification workflows.

Positive

  • Multi-parameter measurement capability: Supports conductivity, TDS, salinity, resistivity, and temperature in a single instrument, reducing the need for multiple dedicated meters in water quality and environmental sampling applications.
  • Automatic range segmentation: Conductivity range automatically segments from 0-19.99 µS/cm to 20.00-199.9 mS/cm, enabling precise readings across low to high conductivity samples without manual range switching.

Trade-offs

  • Single-point calibration limitation: Conductivity calibration is limited to 1 point, which may reduce accuracy across wide measurement ranges compared to multi-point calibration systems, particularly in high-precision laboratory workflows.
  • External power dependency: Requires a DC12V power supply, limiting portability and necessitating access to mains power or a compatible external battery source for field or remote deployment.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).