Description
IoniSense pH 100 T Touch Screen Benchtop Electrochemistry MeterProduct Type: Touch Screen Benchtop Electrochemistry Meter
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, platform compatibility or configuration confirmation, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
The instrument requires electrode and probe compatibility with the selected measurement parameter (pH, mV, ORP). Calibration must be performed using 1-5 point automatic calibration with appropriate buffer solutions to maintain accuracy.
- Electrode Compatibility: The meter requires a compatible IoniProbe pH electrode (button or touch model) and a temperature probe for accurate measurement.
- Calibration Requirements: Use fresh pH buffer solutions for each 1-5 point automatic calibration cycle to ensure measurement accuracy.
- Temperature Compensation: Automatic temperature compensation operates over (-10.0 to 135.0) °C; ensure the temperature probe is connected and immersed in the sample.
- Measurement Range Limits: The measurable pH range is -2.000 to 20.000 pH; confirm the sample pH falls within this range before use.
This procedure guides the user through initial setup, calibration, and measurement using the benchtop electrochemistry meter. Proper electrode selection and calibration are critical for accurate readings.
Required Equipment: IoniSense pH 100 T Meter, IoniProbe pH Electrode (button or touch model), IoniProbe Temperature Electrode
- Select Electrode
Select the appropriate IoniProbe pH electrode and temperature probe for the intended measurement parameter. - Connect Electrodes
Connect the pH electrode and temperature probe to the meter's input ports and secure them firmly. - Power On
Connect the power adapter and press the power button to turn on the instrument. - Calibrate
Perform a 1-5 point automatic calibration by immersing the electrodes in standard buffer solutions and following the on-screen prompts. - Measure Sample
Immerse the electrodes in the sample solution, stir gently, and record the stable reading once displayed.
What is the advantage of the 1-5 point automatic calibration on the IoniSense pH 100 T, and how does it affect the accuracy across the full pH range?
The 1-5 point automatic calibration allows the meter to compensate for electrode non-linearity. With a 5-point calibration, the meter can achieve the stated accuracy of ±0.002 pH ±1 digit across the entire -2.000 to 20.000 pH range. The automatic feature simplifies the calibration process.
Does the IoniSense pH 100 T require a separate temperature probe for accurate pH measurement, and is it included?
Yes, the touch model comes with a IoniProbe Temperature 01 temperature electrode for automatic temperature compensation. The meter can compensate across -10.0 to 135.0°C. The temperature electrode is included in the standard package.
What power and data connectivity options are available for the IoniSense pH 100 T, and is the magnetic stirrer included in the standard package?
The meter is powered by a DC12V adapter (included) and supports data output via USB, PC, or printer. The standard package also includes a magnetic stirrer, which facilitates sample mixing during measurements.
The IoniSense pH 100 T is a benchtop electrochemistry meter offering high-precision pH measurement (±0.002 pH) with 1-5 point automatic calibration, ORP (mV) and temperature measurement, and auto temperature compensation. It requires a DC12V power supply and includes specific electrodes, necessitating configuration confirmation before purchase.
Positive
- High accuracy pH with multi-point calibration: Achieves ±0.002 pH accuracy and supports 1-5 point automatic calibration, enabling reliable and reproducible pH measurements in laboratory and field applications.
- Multi-parameter measurement with auto compensation: Measures pH, ORP (mV), and temperature with automatic temperature compensation across a wide range (-10.0 to 135.0 °C), reducing workflow complexity for diverse electrochemical assays.
Trade-offs
- Electrode and probe compatibility must be verified: The instrument ships with specific electrodes (pH electrode and temperature probe) and requires upfront confirmation of measurement parameter, range, and compatible probe configuration, adding a pre-purchase validation step.
- External DC12V power supply required: Operates exclusively on a DC12V power adapter, limiting portability for field use and necessitating access to a mains power source or a suitable external battery supply.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).