IoniSense pH Conductivity DO 100 Benchtop Meter ATOMFAIR®

$630.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Research-grade benchtop electrochemistry meter for pH, ORP and conductivity workflows, with -2.000–20.000 pH range, ±0.01 pH accuracy, USB output. Order now.

Description

IoniSense pH Conductivity DO 100 Benchtop Electrochemistry Meter

Product Type: Benchtop Electrochemistry Meter
Research-grade laboratory product

Product Overview

Benchtop Electrochemistry Meter IoniSense pH Conductivity DO 100 Benchtop Electrochemistry Meter supports pH / mV / °C; mV (ORP) / °C; conductivity / TDS / salinity / resistivity / °C and (-9.9-130.0) °C / (14.1-266.0) °F.

The instrument is intended for electrochemical measurement workflows such as water quality screening, environmental sampling, aquaculture, education, process checks and laboratory verification when those applications match the selected measurement parameter.

Confirm the required measurement parameter, electrode or probe configuration and operating range before quotation.

Performance Features

  • Measurement parameter: pH / mV / °C; mV (ORP) / °C; conductivity / TDS / salinity / resistivity / °C.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-IONSPHCONDUCTIVITYDO100
Model IoniSense pH Conductivity DO 100
Measurement parameters pH / mV / °C; mV (ORP) / °C; conductivity / TDS / salinity / resistivity / °C
pH range (-2.000-20.000) pH
pH resolution 0.1 / 0.01 / 0.001
pH accuracy ±0.01 pH ±1 digit
Calibration points 1-3 point automatic calibration
Temperature auto compensation (-9.9-130.0) °C / (14.1-266.0) °F
Temperature range (-9.9-130.0) °C / (14.1-266.0) °F
Temperature accuracy ±0.2 °C
Data output USB / PC / printer
Power supply DC12V
Standard package Instrument; pH electrode, conductivity electrode and dissolved oxygen accessories according to model configuration; standard solutions; universal electrode holder; magnetic stirrer; power adapter

Selection and Use Notes

  • Confirm measurement parameter, range, accuracy, calibration requirement, temperature compensation and compatible electrode or probe before quotation.
PROCUREMENT CHECK: Confirm model, working range, compatibility, consumables and required configuration before quotation.
DOCUMENTATION REVIEW: Product specifications and configuration details are reviewed against laboratory use requirements.
ACCESSORY MATCHING: Compatible accessories, replacement parts and consumables can be matched according to the selected configuration.
RFQ NOTE: Include the required model, configuration and quantity when requesting quotation support.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, platform compatibility or configuration confirmation, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

This benchtop meter requires calibration and temperature compensation for accurate multiparameter measurements. Electrode compatibility and power supply configuration must be verified before use.

  • Calibration Requirement: Automatic calibration using 1 to 3 points is required to maintain accuracy across the pH range.
  • Temperature Compensation: The instrument applies automatic temperature compensation only within the range of -9.9 to 130.0 °C.
  • Electrode Compatibility: The selected electrode or probe must match the intended measurement parameter and operating range.
  • Power Supply: The meter requires a stable DC12V power supply; use only the included power adapter.
  • Data Output Interface: Data export via USB, PC, or printer requires compatible interfaces and drivers.

Does the IoniSense pH Conductivity DO 100 benchtop meter support dissolved oxygen measurement as a standard feature, or is it an optional configuration?

The IoniSense pH Conductivity DO 100 benchtop meter supports dissolved oxygen measurement only when ordered with the specific configuration that includes dissolved oxygen accessories. The standard package includes dissolved oxygen accessories according to model configuration, but the listed measurement parameters do not include dissolved oxygen as a standard parameter, confirming it is an optional capability.

What is the maximum temperature range for automatic temperature compensation on the IoniSense pH Conductivity DO 100 meter?

The automatic temperature compensation range for the IoniSense pH Conductivity DO 100 meter is (-9.9 to 130.0) °C (14.1 to 266.0 °F), as specified in the technical specifications for temperature auto compensation and temperature range.

What power supply is required for the IoniSense pH Conductivity DO 100 benchtop meter?

The IoniSense pH Conductivity DO 100 benchtop meter requires a DC12V power supply, and the standard package includes a power adapter. Users should confirm compatibility with local mains voltage before use.

The IoniSense pH Conductivity DO 100 is a benchtop electrochemistry meter offering comprehensive multi-parameter measurement (pH, conductivity, DO, etc.) with high accuracy and resolution, but requires careful pre-configuration and external power/data connectivity for operation.

Positive

  • Multi-parameter electrochemical measurement capability: Supports pH, mV, conductivity, TDS, salinity, resistivity, and dissolved oxygen, enabling versatile water quality and laboratory analysis without needing separate instruments.
  • High precision pH and temperature accuracy: pH accuracy within ±0.01 pH and temperature accuracy within ±0.2°C, with selectable pH resolution down to 0.001, suitable for demanding analytical workflows.

Trade-offs

  • Requires external DC power and data interface: Operates on a DC12V supply and outputs data via USB, PC, or printer, requiring dedicated power and data connectivity infrastructure in the lab.
  • Configuration must be confirmed before use: The instrument's measurement parameters, electrode/probe compatibility, and calibration needs must be explicitly specified by the user, meaning it may not be ready for all applications out of the box.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).