Benchtop Dissolved Oxygen Meter DO 100 0-20 mg/L ATOMFAIR®

$375.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

IoniSense DO 100 benchtop dissolved oxygen meter measures 0.00-20.00 mg/L DO with ±0.30 mg/L accuracy, 0-200 kPa auto pressure compensation. Order now.

SKU: AF-EI-E-BENC-DO00-QCJ2
Category:
Tags: , ,
Brands:

Description

IoniSense DO 100 Benchtop Electrochemistry Meter

Product Type: Benchtop Electrochemistry Meter
Research-grade laboratory product

Product Overview

Benchtop Electrochemistry Meter IoniSense DO 100 Benchtop Electrochemistry Meter supports Dissolved oxygen / °C and (-9.9-130.0) °C / (14.1-266.0) °F.

The instrument is intended for electrochemical measurement workflows such as water quality screening, environmental sampling, aquaculture, education, process checks and laboratory verification when those applications match the selected measurement parameter.

Confirm the required measurement parameter, electrode or probe configuration and operating range before quotation.

Performance Features

  • Measurement parameter: Dissolved oxygen / °C.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-IONSDO100
Model IoniSense DO 100
Measurement parameters Dissolved oxygen / °C
Dissolved oxygen range (0.00-20.00) mg/L
Dissolved oxygen accuracy ±0.30 mg/L
Oxygen saturation range (0.0-200.0)%
Air pressure compensation Automatic, 0-200.0 kPa
DO temperature compensation (0.0-50.0) °C / (32.0-122.0) °F
Salinity compensation Manual, 0-45 ppt
Temperature range (-9.9-130.0) °C / (14.1-266.0) °F
Temperature accuracy ±0.2 °C
Data output USB / PC / printer
Power supply DC12V
Standard package Instrument; IoniProbe DO 01 2 M polarographic dissolved oxygen electrode or IoniProbe DO 01 2 M optical dissolved oxygen electrode depending on model; IoniProbe DO S dissolved oxygen membrane cap; power adapter

Selection and Use Notes

  • Confirm measurement parameter, range, accuracy, calibration requirement, temperature compensation and compatible electrode or probe before quotation.
PROCUREMENT CHECK: Confirm model, working range, compatibility, consumables and required configuration before quotation.
DOCUMENTATION REVIEW: Product specifications and configuration details are reviewed against laboratory use requirements.
ACCESSORY MATCHING: Compatible accessories, replacement parts and consumables can be matched according to the selected configuration.
RFQ NOTE: Include the required model, configuration and quantity when requesting quotation support.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, platform compatibility or configuration confirmation, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

The instrument requires selection of the correct electrode configuration and calibration routine before measurement. Accurate dissolved oxygen readings depend on proper temperature, air pressure, and salinity compensation settings.

  • Electrode Configuration: Confirm that the polarographic or optical dissolved oxygen electrode is compatible with the measurement parameter and sample matrix.
  • Calibration Requirement: Perform calibration using a certified standard or air-saturated water before each measurement series to ensure accuracy.
  • Compensation Settings: Enable automatic air pressure compensation and manually set salinity compensation according to the sample conditions.
  • Temperature Compensation: Allow the electrode and sample to equilibrate to the same temperature before recording readings.
  • Data Output: Connect the instrument to a PC or printer via USB for data logging and documentation.

How does the 0–200.0 kPa automatic air pressure compensation range affect dissolved oxygen measurement accuracy at high altitudes?

The automatic air pressure compensation covers 0–200.0 kPa, which includes high-altitude low-pressure environments. This ensures the instrument corrects for barometric pressure variations without manual adjustment, maintaining the stated ±0.30 mg/L accuracy across the full dissolved oxygen measurement range of 0.00–20.00 mg/L.

Can the IoniSense DO 100 benchtop meter be used with non-Atomfair polarographic or optical dissolved oxygen sensors, or is it limited to the specified IoniProbe DO 01 electrode?

The IoniSense DO 100 is configured exclusively with either the IoniProbe DO 01 polarographic or IoniProbe DO 01 optical dissolved oxygen electrode (2 m cable), depending on the model ordered. No compatibility with third-party sensors is stated. The system also requires the IoniProbe DO S membrane cap for proper operation, confirming a closed-probe architecture.

What power supply and data infrastructure are required to operate the IoniSense DO 100 in a laboratory setting?

The instrument requires a DC12V power supply, which is included in the standard package as a power adapter. For data output, the meter provides USB, PC, and printer interfaces, so a computer with a USB port or a compatible printer is needed for data logging. No special laboratory infrastructure beyond a standard benchtop and electrical outlet is specified.

The IoniSense DO 100 benchtop meter offers dual electrode flexibility and automatic air pressure compensation, but requires manual salinity input and its DO accuracy of ±0.30 mg/L may limit use in some high-precision applications.

Positive

  • Dual electrode type support: The instrument can be configured with either a polarographic or optical dissolved oxygen electrode, providing flexibility for different application requirements and maintenance preferences.
  • Automatic air pressure compensation: The meter automatically compensates for air pressure variations from 0 to 200.0 kPa, reducing the need for manual adjustments and improving accuracy across different altitudes.

Trade-offs

  • Manual salinity compensation required: Salinity compensation must be set manually for 0-45 ppt, which introduces an additional calibration step and potential for user error in brackish or seawater samples.
  • Moderate dissolved oxygen accuracy: The DO accuracy of ±0.30 mg/L may be insufficient for high-precision environmental monitoring or research applications requiring tighter tolerances.