IoniSense Conductivity Pocket Tester 0-19.99 mS/cm ATOMFAIR®

$75.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Pocket electrochemistry tester for conductivity measurement with 0-19.99 mS/cm range, ±1.0% F.S. ±1 digit accuracy, and automatic calibration.

Description

IoniSense Conductivity 1 Pocket Electrochemistry Tester

Product Type: Pocket Electrochemistry Tester
Research-grade laboratory product

Product Overview

Pocket Electrochemistry Tester IoniSense Conductivity 1 Pocket Electrochemistry Tester supports Conductivity across 0-19.99 mS/cm; 0-60 °C with ±1.0%F.S ±1 digit and 0-60 °C on pocket meters; -10 to 135 °C on portable meters where applicable.

The instrument is intended for electrochemical measurement workflows such as water quality screening, environmental sampling, aquaculture, education, process checks and laboratory verification when those applications match the selected measurement parameter.

Calibration and temperature-compensation details are retained in the technical table so the selected model can be matched to the required parameter, range and workflow.

Performance Features

  • Measurement parameter: Conductivity.
  • Measurement range: 0-19.99 mS/cm; 0-60 °C.
  • Accuracy: ±1.0%F.S ±1 digit.
  • Calibration: Automatic calibration for supported parameters.
  • Temperature compensation: Automatic temperature compensation on supported models.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-IONSCONDUCTIVITY1
Measurement parameters Conductivity
Accuracy ±1.0%F.S ±1 digit
Measurement range 0-19.99 mS/cm; 0-60 °C
Temperature range 0-60 °C on pocket meters; -10 to 135 °C on portable meters where applicable
Calibration Automatic calibration for supported parameters
Temperature compensation Automatic temperature compensation on supported models
Package / accessories Electrode or probe, calibration solution, sample bottle, batteries, lanyard and carrying case according to model configuration

Selection and Use Notes

  • Confirm measurement parameter, range, accuracy, calibration requirement, temperature compensation and compatible electrode or probe before quotation.
PROCUREMENT CHECK: Confirm model, working range, compatibility, consumables and required configuration before quotation.
DOCUMENTATION REVIEW: Product specifications and configuration details are reviewed against laboratory use requirements.
ACCESSORY MATCHING: Compatible accessories, replacement parts and consumables can be matched according to the selected configuration.
RFQ NOTE: Include the required model, configuration and quantity when requesting quotation support.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, platform compatibility or configuration confirmation, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

This pocket electrochemistry tester requires automatic calibration and temperature compensation for accurate conductivity measurements. The instrument must be used with compatible electrodes and within its specified operating ranges to avoid erroneous readings.

  • Calibration Requirement: Automatic calibration must be performed using the appropriate calibration solution to ensure measurement accuracy within ±1.0%F.S ±1 digit.
  • Temperature Compensation: Automatic temperature compensation is active only within the 0-60 °C range on pocket meters, so measurements outside this range may require correction.
  • Measurement Range: The conductivity measurement must be limited to 0-19.99 mS/cm to maintain specified accuracy and avoid sensor damage.
  • Electrode Compatibility: A compatible electrode or probe specific to conductivity measurement must be used to ensure proper function and accuracy.
  • Operating Temperature: The device must be operated within 0-60 °C ambient temperature to ensure reliable readings and prevent damage.

How does the ±1.0%F.S ±1 digit accuracy specification of the IoniSense Conductivity 1 pocket tester apply across the 0-19.99 mS/cm measurement range?

The ±1.0%F.S ±1 digit accuracy applies to the full 0-19.99 mS/cm conductivity range and over the 0-60 °C operating temperature range. The model features automatic temperature compensation to maintain accuracy across varying sample temperatures, as indicated in the technical specifications.

What calibration solutions are compatible with the IoniSense Conductivity 1's automatic calibration function?

The IoniSense Conductivity 1 supports automatic calibration for conductivity parameters. The package includes a calibration solution appropriate for the model configuration. Users should select standards that fall within the 0-19.99 mS/cm measurement range to match the instrument's supported parameters.

What accessories are included with the IoniSense Conductivity 1 pocket tester, and which are consumables?

The package includes an electrode or probe, calibration solution, sample bottle, batteries, lanyard, and carrying case according to model configuration. Calibration solution and batteries are consumables that require periodic replacement; the carrying case is provided for storage and transport.

The IoniSense Conductivity 1 Pocket Tester (model AF-IONSCONDUCTIVITY1) is a compact conductivity meter with automatic calibration and temperature compensation, suitable for routine water quality screening and environmental sampling within 0–19.99 mS/cm and 0–60 °C. Its ±1.0% F.S. ±1 digit accuracy is adequate for field checks and educational use but does not meet the precision required for high-accuracy research workflows.

Positive

  • Automatic calibration and temperature compensation: Supports automatic calibration for conductivity and automatic temperature compensation, reducing manual adjustment steps and improving measurement consistency during routine screening.
  • Wide conductivity range for field use: Covers 0–19.99 mS/cm and 0–60 °C, making it directly applicable to water quality checks, aquaculture monitoring, and educational demonstrations without requiring additional range modules.

Trade-offs

  • Moderate accuracy limits research use: Specified accuracy of ±1.0% F.S. ±1 digit is acceptable for process checks and field screening but may be insufficient for high-precision laboratory or analytical chemistry applications that require tighter tolerances.
  • Restricted temperature range on pocket model: The pocket meter operates only from 0–60 °C; the extended range (-10 to 135 °C) listed for portable meters does not apply to this specific model, limiting its use in hot process streams or low-temperature environments.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).