Dry Bath Heating Block 40×0.2 mL AF-MINI40X02 ATOMFAIR®

$87.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

AF-MINI40X02 dry bath heating block module fits 40 × 0.2 mL vessels with 6.4 × 17 mm holes for Mini HCL100, HC100 and H100 platforms. Order now.

Description

Mini Dry Bath Heating Block Module, 40 x 0.2 mL

Product Type: Thermal Control Accessory
Research-grade laboratory product

Product Overview

Thermal control block module for 40 x 0.2 mL vessels provides the physical tube or plate interface required to match the dry bath platform with the selected laboratory consumables.

The module selection should be confirmed against vessel size, hole geometry and compatible instrument family before quotation.

Performance Features

  • 40 x 0.2 mL module format supports vessel-specific temperature transfer.
  • Hole geometry is specified to support compatibility review before ordering.
  • Compatible dry bath family should be confirmed with the selected instrument.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-MINI40X02
Product Family Mini HCL100, Mini HC100 and Mini H100
Module capacity 40 x 0.2 mL
Hole diameter and depth 6.4 x 17 mm
Module format Heating block module
Compatibility Mini HCL100, Mini HC100 and Mini H100

Selection and Use Notes

  • Confirm vessel dimensions and compatible dry bath model before quotation.
PROCUREMENT CHECK: Confirm model, working range, compatibility, consumables and required configuration before quotation.
DOCUMENTATION REVIEW: Product specifications and configuration details are reviewed against laboratory use requirements.
ACCESSORY MATCHING: Compatible accessories, replacement parts and consumables can be matched according to the selected configuration.
RFQ NOTE: Include the required model, configuration and quantity when requesting quotation support.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, platform compatibility or configuration confirmation, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

This heating block module is designed exclusively for use with Atomfair Mini HCL100, Mini HC100, and Mini H100 dry bath instruments. Proper function requires matching the 6.4 mm diameter by 17 mm depth wells to 0.2 mL vessel dimensions.

  • Vessel Size Compatibility: Confirm that the outer diameter of the 0.2 mL tube does not exceed 6.4 mm to ensure proper fit within the well.
  • Instrument Family Compatibility: Verify that the dry bath platform is one of the compatible models: Mini HCL100, Mini HC100, or Mini H100.
  • Well Depth Verification: Ensure the tube length does not exceed 17 mm to avoid interference with the well bottom.
  • Module Seating Requirement: The module must be fully seated into the dry bath receptacle to achieve uniform thermal contact.

What are the dimensional tolerances for tube compatibility with the 6.4 mm diameter holes in the Mini Dry Bath Heating Block Module?

The module is designed for 40 x 0.2 mL vessels with a hole diameter of 6.4 mm and depth of 17 mm. While the specification does not list tolerances, it is critical to confirm vessel dimensions before quotation to ensure proper thermal contact and avoid jamming or poor heat transfer.

Is the AF-MINI40X02 heating block module backward compatible with the Mini H100 dry bath platform?

Yes, the module is compatible with the Mini H100, as well as the Mini HCL100 and Mini HC100 dry baths, as specified in the technical specifications. However, compatibility should be verified by confirming the instrument family and model number before ordering to ensure proper fit and thermal coupling.

What are the recommended storage conditions and handling precautions for the Atomfair Mini Dry Bath Heating Block Module when not in use?

The product description advises reviewing the configuration and compatible accessories before quotation. As a precision-machined thermal interface component, it should be stored in a clean, dry environment away from corrosive chemicals or extreme temperatures. Avoid dropping or scratching the block surface to maintain thermal contact quality.

The AF-MINI40X02 heating block module provides precise thermal transfer for 40 x 0.2 mL vessels and is compatible with the Mini HCL100, Mini HC100, and Mini H100 dry bath series. Compatibility verification with vessel dimensions and instrument model is required prior to procurement.

Positive

  • 40 x 0.2 mL vessel capacity: The module accommodates 40 standard 0.2 mL tubes, enabling parallel processing of multiple samples in PCR or similar applications.
  • Cross-platform dry bath compatibility: Designed to fit the Mini HCL100, Mini HC100, and Mini H100 dry bath families, offering flexibility across different instrument models.

Trade-offs

  • Pre-purchase compatibility check mandatory: Vessel size, hole geometry (6.4 x 17 mm), and instrument family must be confirmed before ordering to ensure proper fit and thermal transfer.
  • Limited to specific dry bath series: The module is only compatible with the Mini HCL100, Mini HC100, and Mini H100 series; it cannot be used with other dry bath platforms without verification.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).