HM100-Pro Heating Shaking Dry BathProduct Type: Temperature control instrument
Research-grade temperature control platform
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
This document outlines operational constraints and safety limits for the HM100-Pro Heating Shaking Dry Bath. Compliance with these constraints ensures safe and reliable operation of the instrument.
- Electrical Supply Requirements: Operate the unit only with the specified power supply of 110/220 V, 50/60 Hz to prevent electrical damage or hazard.
- Ambient Environment Limits: Maintain ambient temperature between 10 and 40 °C and relative humidity below 80% to avoid condensation and overheating.
- Thermal Safety Precautions: Never touch the heating block or sample vessels during or immediately after operation, as surface temperatures can exceed 100 °C.
- Block Compatibility Warning: Use only confirmed compatible heating blocks or modules to ensure proper fit and uniform heat transfer.
- Overload Prevention: Do not exceed the maximum sample load or block weight specified for the shaking mechanism to avoid mechanical failure.
Follow these steps to correctly set up and operate the HM100-Pro Heating Shaking Dry Bath. These actions ensure safe handling and accurate temperature control during sample incubation.
Required Equipment: Compatible heating block or module, Sample vessels (tubes, vials, or plates)
- Verify Power Supply
Confirm that the mains power matches the unit's nameplate rating (110/220 V, 50/60 Hz) and plug into a grounded outlet. - Install Compatible Heating Block
Select a heating block or module that accommodates your sample vessel format and securely insert it into the dry bath. - Set Temperature and Timer
Use the TFT interface to program the desired temperature (0 to 100 °C) and timer duration (0 min to 99 h 59 min). - Load Samples
Place sample vessels into the heating block, ensuring they are properly seated and balanced to prevent spillage. - Start Shaking and Heating
Initiate the shaking function at the required speed (200 to 1500 rpm) and allow the block to reach the set temperature. - Monitor Operation
Observe the TFT display for actual temperature and timer progress; adjust parameters only when the unit is not in active heating mode. - Power Off and Cool Down
After the timer expires, stop shaking, power off the unit, and allow the heating block to cool below 40 °C before handling.
How does the maximum heating rate of 5.5°C/min affect temperature control accuracy for sensitive enzymatic reactions on the HM100-Pro?
The HM100-Pro maintains a temperature control accuracy of ±0.5°C at steady state despite a maximum heating rate of 5.5°C/min. For highly temperature-sensitive reactions, users should note that while the steady-state accuracy is specified, rapid ramp rates may require programmed slower ramps to minimize transient overshoot; the instrument supports custom program capacity of 9 programs with 150 process execution steps.
Which heating blocks or sample modules are compatible with the HM100-Pro heating shaking dry bath?
The product description does not list specific compatible blocks or modules; it explicitly advises confirming block or module compatibility, sample vessel format, and installation environment before ordering. Users must contact the Atomfair technical sales team (inquiry@atomfair.com) for method-specific incubation, heating, or module matching requirements.
What ambient temperature and humidity limits are required for reliable operation of the HM100-Pro dry bath?
The HM100-Pro requires an ambient temperature of 10 to 40°C and relative humidity below 80% for reliable operation. It accepts power supply of 110/220 V, 50/60 Hz and draws 200 W, making it suitable for standard laboratory bench environments within those limits.
The HM100-Pro Heating Shaking Dry Bath provides dry-block heating with orbital shaking for uniform sample incubation and mixing across a temperature range of ambient to 100°C, with ±0.5°C accuracy. Its operation requires selection of compatible heating blocks or modules, and lacks active cooling below ambient temperature.
Positive
- Integrated heating and orbital mixing: Combines dry-block heating with orbital shaking (200–1500 rpm, 3 mm orbit) for simultaneous incubation and mixing in a single instrument, reducing workflow steps and contamination risk.
- Programmable timed operation: Supports up to 9 custom programs and 150 process execution steps with a timer range of 0 min to 99 h 59 min, enabling automated, reproducible protocols for extended or multi-step sample preparation.
Trade-offs
- Block compatibility must be user-verified: The unit requires separately selected heating blocks or modules matched to the specific sample vessel format; failure to confirm compatibility before ordering can delay deployment or cause operational mismatch.
- No active cooling below ambient: Temperature control is limited to heating from room temperature up to 100°C; the instrument cannot cool below ambient, restricting its use for cold incubation or low-temperature reactions without external cooling.