Description
ATOMFAIR® HB150-S2 Dry BathProduct Type: Temperature control instrument
Atomfair Model: AF-TC-HB150-S2
Research-grade temperature control platform
|
|||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||
|
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
The instrument requires an ambient temperature of 10 to 40 °C and relative humidity below 80% for stable operation. Temperature control accuracy degrades above 90 °C, with a specified tolerance of ±0.6 °C from 90 to 150 °C.
- Ambient Operating Range: Operate the dry bath only within an ambient temperature range of 10 to 40 °C and relative humidity below 80% to maintain specified performance.
- Temperature Accuracy Degradation at High Setpoints: When setting the block temperature above 90 °C, expect control accuracy to widen to ±0.6 °C compared to ±0.3 °C in the 25 to 90 °C range.
This procedure covers initial setup, block installation, and routine operation for temperature-sensitive workflows. Follow each step sequentially to ensure safe and accurate thermal control.
Required Equipment: ATOMFAIR HB150-S2 Dry Bath unit, Compatible sample block or module
- Place the instrument on a stable, level surface
Position the dry bath on a clean, level benchtop away from direct sunlight and drafts to ensure uniform heat distribution. - Install the appropriate sample block
Insert the compatible block or module into the heating well, ensuring full contact with the base for optimal thermal transfer. - Connect the power supply and turn on the unit
Plug the power cord into a grounded outlet matching the specified voltage (110/220 V, 50/60 Hz) and switch on the main power. - Set the target temperature and timer
Use the LED interface to enter the desired temperature between 25 and 150 °C and set the timer from 0 minutes up to 99 hours 59 minutes. - Load samples into the preheated block
Once the display indicates the setpoint has been reached, carefully place tubes or plates into the block wells without overfilling. - Monitor the run and retrieve samples upon completion
Allow the timer to elapse or stop the run manually, then remove samples using heat-resistant gloves if the block temperature exceeds 60 °C.
What is the temperature control accuracy trade-off between the lower and upper operating ranges of the Atomfair HB150-S2 dry bath?
The accuracy is ±0.3°C from 25°C to 90°C, but degrades to ±0.6°C from 90°C to 150°C per the technical specifications. Applications requiring tight thermal control above 90°C must account for this reduced precision.
Can the Atomfair HB150-S2 dry bath perform active cooling below ambient temperature?
No, the temperature control range is room temperature +5°C to 150°C with a setting range of 25°C to 150°C. It cannot cool below ambient; only heating above room temperature is supported, which is a constraint for protocols requiring rapid cooling or sub-ambient incubation.
What are the ambient operating limits for the Atomfair HB150-S2 dry bath and how do they affect laboratory placement?
The instrument must be operated in ambient temperatures of 10°C to 40°C and relative humidity below 80%. It requires a 110/220V, 50/60Hz power supply and consumes 200W. Placement should avoid high-humidity areas and ensure adequate ventilation for heat dissipation.
The Atomfair HB150-S2 Dry Bath offers precise temperature uniformity at 37°C and a wide heating range, but users must account for reduced accuracy above 90°C and controlled ambient requirements.
Positive
- Precise temperature uniformity at 37°C: Uniformity of ±0.2°C at 37°C supports reproducible enzyme reactions and PCR setup.
- Broad operational temperature range: Range from room temperature +5 to 150°C covers incubation, denaturation, and nucleic-acid amplification protocols.
Trade-offs
- Reduced accuracy above 90°C: Temperature control accuracy degrades to ±0.6°C in the 90–150°C range, which may limit high-temperature applications requiring tighter tolerance.
- Restricted ambient operating conditions: Ambient temperature must be between 10 and 40°C with relative humidity below 80%, limiting use in unconditioned laboratory spaces.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).