Dry Bath Incubator H100-Pro TFT 100°C ±0.5°C ATOMFAIR®

$385.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

H100-Pro dry bath provides room temperature +5 to 100°C control, ±0.5°C accuracy and uniformity, 200 W power, TFT display, 99 h 59 min timer. Order now.

Description

H100-Pro Dry Bath

Product Type: Temperature control instrument
Research-grade temperature control platform

Product Overview

H100-Pro Dry Bath is a research-grade dry bath for controlled block-based heating and incubation of tubes, vials, plates or compatible sample modules in molecular biology, biochemistry, clinical research, quality-control and teaching laboratories. The listed configuration provides temperature control range of Room temperature +5 to 100 °C, temperature control accuracy of ±0.5 °C, uniformity of ±0.5 °C.

It is suitable for enzyme reactions, sample warming, reagent preparation, nucleic-acid workflow support, protein handling and routine temperature-controlled sample preparation. Select the model according to timer setting (0 min to 99 h 59 min), installation footprint (200 x 235 x 120 mm), block or module format, sample vessel size, power supply, operating environment.

Key Features and Advantages

  • Dry-block temperature control supports repeatable incubation, warming and sample preparation workflows.
  • Temperature range: Room temperature +5 to 100 °C.
  • Temperature control accuracy: ±0.5 °C.
  • Timer range: 0 min to 99 h 59 min.
  • Display: TFT.
  • Confirm compatible heating blocks, modules or sample vessels before ordering.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-TC-H100-PRO
Temperature control range Room temperature +5 to 100 °C
Temperature setting range 0 to 100 °C
Temperature control accuracy ±0.5 °C
Uniformity at 37 °C ±0.5 °C
Power 200 W
Timer 0 min to 99 h 59 min
Display TFT
Power supply 110/220 V, 50/60 Hz
Dimensions 200 x 235 x 120 mm
Weight 7.3 kg
Ambient temperature 10 to 40 °C
Relative humidity <80%
Configuration Guidance: Confirm temperature range, block or module compatibility, sample vessel format, power supply and installation environment before ordering.
Technical Support: For method-specific incubation, heating, cooling or module matching requirements, contact the Atomfair technical sales team.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

The H100-Pro Dry Bath requires controlled ambient conditions of 10–40°C and <80% relative humidity for accurate temperature regulation. Compatibility with specific heating blocks and sample vessels must be verified prior to operation to ensure proper thermal contact.

  • Temperature Range Constraint: The instrument must be operated within the temperature control range of room temperature plus 5°C to 100°C to avoid exceeding design limits.
  • Power Supply Constraint: The dry bath must be connected to a power supply matching 110/220 V, 50/60 Hz to prevent electrical damage.
  • Environmental Constraint: Ambient temperature must be maintained between 10°C and 40°C with relative humidity below 80% to avoid condensation or overheating.
  • Block Compatibility Constraint: Only compatible heating blocks or modules matching the sample vessel format should be used to ensure uniform heat transfer and avoid instrument damage.

What is the temperature uniformity of the H100-Pro Dry Bath at set points above 37°C, such as 70°C or 90°C?

The product specification only provides uniformity data at 37°C (±0.5°C). Uniformity at other temperatures within the range (RT+5 to 100°C) is not explicitly stated, but the stated control accuracy of ±0.5°C applies across the entire range. For high-temperature uniformity data, contact Atomfair technical support.

What tube or vial sizes are compatible with the H100-Pro Dry Bath without a dedicated block?

The product description does not list specific tube or vial sizes. The dry bath is designed for block-based heating, so sample vessels must be used with a compatible heating block or module. Confirm block format and sample vessel compatibility with the manufacturer before ordering.

What are the ambient operating conditions required for the H100-Pro Dry Bath to maintain its specified accuracy?

The H100-Pro Dry Bath requires an ambient temperature of 10 to 40°C and relative humidity below 80% to operate within its specifications. It accepts 110/220V, 50/60Hz power supply (200W). Ensure adequate ventilation around the 200x235x120 mm footprint.

The H100-Pro Dry Bath is a research-grade heating block incubator with ±0.5°C accuracy and uniformity, suitable for typical molecular biology and biochemistry protocols. Its operation is constrained to heating above ambient and requires block compatibility verification.

Positive

  • Dry-block temperature stability with ±0.5°C accuracy: The H100-Pro Dry Bath provides precise temperature control accuracy and uniformity of ±0.5°C, suitable for enzyme reactions and nucleic-acid workflows requiring stable incubation.
  • Extended timer range for flexible protocols: Timer range from 0 min to 99 h 59 min accommodates both short and long-duration incubation protocols common in molecular biology and biochemistry.

Trade-offs

  • No active cooling capability: Temperature control range starts at room temperature +5 °C, meaning the unit cannot cool samples below ambient temperature; users requiring sub-ambient incubation must consider alternative systems.
  • Requires pre-confirmation of block compatibility: The dry bath operates with specific heating blocks or modules; users must verify compatibility with their sample vessels before ordering to ensure proper thermal contact and fit.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).