Description

HiPette Single-channel 10-100 µL Pipette

Product Type: Fully autoclavable manual pipette
Research-grade liquid handling platform

Product Overview

HiPette Single-channel 10-100 µL Pipette is a fully autoclavable manual pipette for accurate microliter liquid handling in research, quality-control and teaching laboratories. The 10-100 µL range supports single-tube sample preparation, reagent addition, serial dilution, PCR or qPCR setup and routine analytical transfer where repeatability, stable tip fit and traceable calibration data are important.

Select this model according to its single-channel format, 10-100 µL working range, 0.1 µL increment, compatible tips and sterilization requirements. The technical specifications list the order model, product family, test volumes, systematic error, random error and calibration reference for procurement, method setup and routine performance review.

Key Features and Advantages

  • Single-channel configuration for single-tube sample preparation, reagent addition, serial dilution, PCR or qPCR setup and routine analytical transfer.
  • Volume range 10-100 µL with 0.1 µL increment.
  • Sterilization suitability: Fully autoclavable.
  • Systematic error and random error values are listed by test volume for calibration review.
  • Suitable for routine liquid transfer, assay setup, sample preparation and laboratory training workflows.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-LH-HIPETTE-10-100-µL
Product Family HiPette
Channel count Single-channel
Volume range 10-100 µL
Increment 0.1 µL
Test volume(s) 100 / 50 / 10 µL
Systematic error At 100 µL: ±0.80 µL (±0.8%); at 50 µL: ±0.50 µL (±1.0%); at 10 µL: ±0.30 µL (±3.0%)
Random error At 100 µL: ±0.20 µL (±0.2%); at 50 µL: ±0.15 µL (±0.3%); at 10 µL: ±0.10 µL (±1.0%)
Sterilization suitability Fully autoclavable
Calibration reference ISO 8655-2 user calibration reference indicated in the technical table
Technical table note Single-channel adjustable technical table
Configuration Support: Confirm compatible tips, calibration requirements, sterilization needs and laboratory workflow before ordering.
Technical Support: For method-specific volume matching, calibration planning, accessory compatibility or bulk laboratory configuration, contact the Atomfair technical sales team.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

This manual pipette requires periodic calibration per ISO 8655-2 to maintain specified accuracy at test volumes. The device is fully autoclavable, but the user must confirm the autoclave cycle parameters to avoid damage.

  • Calibration Constraint: Systematic and random error must be verified at 100, 50, and 10 µL volumes using the ISO 8655-2 calibration reference.
  • Sterilization Constraint: The pipette can be autoclaved, but no specific disassembly or cycle parameters are provided by the manufacturer.
  • Tip Compatibility Constraint: Only compatible pipette tips must be used to maintain volumetric accuracy and tip retention.

How does the accuracy of the HiPette 10-100 µL pipette change when pipetting volumes near the lower end of the range?

Systematic error increases from ±0.80 µL (±0.8%) at 100 µL to ±0.30 µL (±3.0%) at 10 µL, and random error increases from ±0.20 µL (±0.2%) to ±0.10 µL (±1.0%) per the ISO 8655-2 calibration reference provided in the technical specifications.

Is the HiPette 10-100 µL pipette suitable for PCR or qPCR setup in a molecular biology workflow?

Yes, the product description explicitly lists PCR and qPCR setup as supported applications. The pipette is fully autoclavable, enabling sterilization between runs to prevent cross-contamination, and the single-channel format is appropriate for single-tube reaction preparation.

What sterilization method is approved for the HiPette 10-100 µL pipette and does it require any special preparation?

The pipette is fully autoclavable, meaning it can be sterilized using standard autoclave cycles. No special preparation beyond standard laboratory autoclaving procedures is specified in the product documentation.

A single‑channel manual pipette covering 10–100 µL with full autoclavability and ISO‑traceable error specifications; accuracy degrades at the low end of the range.

Positive

  • Fully autoclavable sterilization: The entire pipette can be autoclaved without disassembly, enabling reliable decontamination between uses in research and teaching labs.
  • Traceable calibration data per test volume: Systematic and random error values are provided at 100 µL, 50 µL and 10 µL with ISO 8655-2 reference, supporting method validation and routine performance review.

Trade-offs

  • Limited to 10–100 µL working range: The pipette cannot handle volumes below 10 µL or above 100 µL; separate instruments are required for sub‑10 µL or larger transfers.
  • Higher relative error at low end: At 10 µL the systematic error is ±3.0% (vs ±0.8% at 100 µL), requiring careful volume selection when accuracy is critical near the lower limit.