SafeVac Vacuum Aspiration System 4 L 600 mbar ATOMFAIR®

$585.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Electronic vacuum aspiration system with 0–600 mbar range and 4 L collection bottle for cell culture fluid removal and wash collection. Order now.

SKU: AF-EI-L-SFVC-VACS-SAFE
Category: ,
Tags:
Brands:

Description

SafeVac Vacuum Aspiration System

Product Type: Vacuum aspiration system
Research-grade liquid handling platform

Product Overview

SafeVac Vacuum Aspiration System is a fully autoclavable manual pipette for accurate microliter liquid handling in research, quality-control and teaching laboratories. The range supports microplate loading, PCR plate preparation, ELISA workflows and repeated parallel reagent transfer where repeatability, stable tip fit and traceable calibration data are important.

Select this model according to its multichannel format, working range, compatible tips and sterilization requirements. The technical specifications list the order model, product family, test volumes, systematic error, random error and calibration reference for procurement, method setup and routine performance review.

Key Features and Advantages

  • Multichannel configuration for microplate loading, PCR plate preparation, ELISA workflows and repeated parallel reagent transfer.
  • Volume range .
  • Sterilization suitability: Fully autoclavable.
  • Systematic error and random error values are listed by test volume for calibration review.
  • Suitable for routine liquid transfer, assay setup, sample preparation and laboratory training workflows.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-LH-SAFEVAC
Vacuum range 0 to 600 mbar
Collection bottle 4 L
Operation Electronic vacuum aspiration
Application Cell culture fluid removal, supernatant aspiration, wash solution collection and laboratory liquid disposal
Configuration Support: Confirm compatible tips, calibration requirements, sterilization needs and laboratory workflow before ordering.
Technical Support: For method-specific volume matching, calibration planning, accessory compatibility or bulk laboratory configuration, contact the Atomfair technical sales team.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

The system operates under vacuum from 0 to 600 mbar and requires a 4 L collection bottle for liquid waste. Full autoclavability ensures sterilization compatibility but imposes material limits on repeated high-temperature cycles.

  • Vacuum Range Constraint: Do not exceed the maximum vacuum of 600 mbar to avoid system damage or fluid overflow.
  • Autoclavability Constraint: Confirm that all components are rated for repeated autoclave cycles before sterilization to prevent material degradation.
  • Collection Bottle Capacity Constraint: Monitor the 4 L collection bottle level during extended use to prevent overflow and contamination of the vacuum system.

This procedure covers initial setup, liquid aspiration, and post-use sterilization for the electronic vacuum aspiration system. Follow these steps to ensure safe and repeatable liquid removal from cell culture or assay plates.

Required Equipment: SafeVac Vacuum Aspiration System, Autoclavable collection bottle (4 L), Compatible aspiration tips

  1. Connect Collection Bottle
    Attach the 4 L collection bottle securely to the vacuum port and verify the seal is intact before powering on the system.
  2. Set Vacuum Level
    Adjust the vacuum control to the desired pressure within the 0 to 600 mbar range based on the liquid viscosity and aspiration speed required.
  3. Aspirate Liquid
    Position the tip at the liquid surface and activate the electronic vacuum to remove supernatant or wash solution without disturbing the cell monolayer.
  4. Empty Collection Bottle
    Disconnect the bottle after use and dispose of the liquid waste according to laboratory safety protocols.
  5. Sterilize Components
    Autoclave the collection bottle and any autoclavable tubing at the recommended cycle to prepare the system for the next use.

How does the SafeVac Vacuum Aspiration System's 0 to 600 mbar vacuum range affect its suitability for delicate cell monolayer aspiration versus high-volume wash collection?

The system provides a vacuum range of 0 to 600 mbar, allowing users to select low settings for gentle aspiration of cell culture supernatants or higher settings for rapid wash collection. The electronic vacuum aspiration operation enables selection within this range, supporting both delicate monolayer work and bulk liquid disposal. Specific pressure increments are not detailed in the source, but the adjustable range accommodates both applications.

Is the SafeVac Vacuum Aspiration System compatible with standard 96-well plates for supernatant removal in microplate assays?

Yes, the system is designed for cell culture fluid removal and supernatant aspiration, and its multichannel configuration supports microplate loading, PCR plate preparation, and ELISA workflows. This makes it suitable for repeated parallel liquid transfer from 96-well plates. However, the source advises confirming compatible tips and accessories before ordering to ensure proper fit and performance.

What sterilization method is recommended for the SafeVac Vacuum Aspiration System, and does it require disassembly before autoclaving?

The SafeVac system is fully autoclavable, meaning the entire system can be sterilized by autoclaving. The source does not specify whether disassembly is required, so standard laboratory procedures for vacuum aspiration systems should be followed, and consulting Atomfair technical support is recommended for detailed preparation guidelines. This ensures sterility for cell culture and biosafety applications.

The SafeVac Vacuum Aspiration System (model AF-LH-SAFEVAC) offers electronic vacuum control from 0 to 600 mbar and a 4 L collection bottle, making it well-suited for cell culture fluid removal and supernatant aspiration in lab settings. Its reliance on mains power and the need to confirm sterilization protocols with the manufacturer are key operational considerations.

Positive

  • Precise electronic vacuum control: The system provides a vacuum range of 0 to 600 mbar, enabling accurate aspiration for cell culture fluid removal, supernatant collection, and wash solution disposal.
  • Large 4 L collection bottle: The 4 L capacity reduces the frequency of emptying during extended workflows, improving laboratory efficiency.

Trade-offs

  • Requires mains power supply: The electronic operation requires a continuous electrical connection, limiting portability and use in field or remote locations without reliable power.
  • Sterilization protocol must be verified: Although the system is described as fully autoclavable, the manufacturer advises confirming sterilization needs before ordering, as electronic components may require disassembly or special handling.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).