dPette+ 8-Channel 15-300 µL Electronic Pipette ATOMFAIR®

$531.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

dPette+ 8-channel electronic pipette with 15-300 µL range, 1 µL increments, ISO 8655-2 calibration reference and lower-half autoclaving.

SKU: AF-EI-L-DPPL-G300-08CH
Category: ,
Tags:
Brands:

Description

dPette+ 8-channel 15-300 µL Pipette

Product Type: 8-channel electronic pipette
Research-grade liquid handling platform

Product Overview

dPette+ 8-channel 15-300 µL Pipette is a fully autoclavable manual pipette for accurate microliter liquid handling in research, quality-control and teaching laboratories. The 15-300 µL range supports microplate loading, PCR plate preparation, ELISA workflows and repeated parallel reagent transfer where repeatability, stable tip fit and traceable calibration data are important.

Select this model according to its 8-channel format, 15-300 µL working range, 1 µL increment, compatible tips and sterilization requirements. The technical specifications list the order model, product family, test volumes, systematic error, random error and calibration reference for procurement, method setup and routine performance review.

Key Features and Advantages

  • 8-channel configuration for microplate loading, PCR plate preparation, ELISA workflows and repeated parallel reagent transfer.
  • Volume range 15-300 µL with 1 µL increment.
  • Sterilization suitability: Lower half autoclavable.
  • Systematic error and random error values are listed by test volume for calibration review.
  • Suitable for routine liquid transfer, assay setup, sample preparation and laboratory training workflows.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-LH-DPETTE-PLUS-8CHANNEL-15-300-µL
Product Family dPette+
Channel count 8-channel
Volume range 15-300 µL
Increment 1 µL
Test volume(s) 300 / 150 / 15 µL
Systematic error At 300 µL: ±1.80 µL (±0.60%); at 150 µL: ±1.50 µL (±1.00%); at 15 µL: ±0.60 µL (±4.00%)
Random error At 300 µL: ±0.90 µL (±0.30%); at 150 µL: ±0.75 µL (±0.50%); at 15 µL: ±0.15 µL (±1.00%)
Sterilization suitability Lower half autoclavable
Calibration reference ISO 8655-2 user calibration reference indicated in the technical table
Technical table note dPette+ multichannel electronic pipette table
Configuration Support: Confirm compatible tips, calibration requirements, sterilization needs and laboratory workflow before ordering.
Technical Support: For method-specific volume matching, calibration planning, accessory compatibility or bulk laboratory configuration, contact the Atomfair technical sales team.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

The dPette+ 8-channel pipette requires periodic calibration at defined test volumes to maintain systematic and random error limits per ISO 8655-2. Only the lower half of the pipette is autoclavable; the upper assembly must not be subjected to steam sterilization.

  • Calibration Requirements: Calibration must be performed at 300, 150, and 15 µL using gravimetric methods to verify the specified accuracy and precision.
  • Sterilization Constraints: Only the lower half of the pipette is autoclavable; the upper assembly must not be subjected to steam sterilization.
  • Tip Compatibility: Use only tips designed for 8-channel pipettes within the 15–300 µL range to ensure correct tip fit and avoid leakage.

How does the accuracy of the dPette+ 8-channel pipette vary across its volume range, and what are the implications for low-volume parallel dispensing?

Systematic error ranges from ±0.60% at 300 µL to ±4.00% at 15 µL, while random error ranges from ±0.30% at 300 µL to ±1.00% at 15 µL, according to the source's test volumes (300, 150, and 15 µL). This means relative accuracy degrades significantly at the lower end of the 15–300 µL range, so researchers should validate precision at their target volume, especially when dispensing 15 µL in parallel microplate or PCR workflows.

Can the entire dPette+ 8-channel electronic pipette be autoclaved, or only specific components?

Only the lower half of the dPette+ 8-channel pipette is autoclavable, as stated in the sterilization suitability specification. The electronic upper assembly should not be autoclaved, so users must follow the indicated partial sterilization procedure to prevent damage to the electronic components.

What calibration procedure does the dPette+ 8-channel pipette require, and how does it comply with ISO 8655-2?

The pipette includes a user calibration reference per ISO 8655-2, as indicated in the technical table. The source lists systematic and random error values at three test volumes (300, 150, and 15 µL) for calibration review, but does not specify the exact adjustment procedure. Operators should refer to the indicated ISO 8655-2 standard for method-specific volume matching and calibration planning.

The dPette+ 8-channel 15-300 µL pipette provides efficient parallel liquid handling for microplate and PCR workflows with autoclavable lower half and ISO 8655-2 calibration traceability, though the ±4% systematic error at 15 µL and partial autoclavability are operational constraints.

Positive

  • Eight-channel parallel liquid handling: The 8-channel configuration enables simultaneous pipetting into 8 wells, significantly increasing throughput for microplate loading, PCR plate preparation, and ELISA workflows.
  • Autoclavable lower half for sterility: The lower half of the pipette can be autoclaved, allowing decontamination between uses without compromising the entire instrument, suitable for aseptic techniques.

Trade-offs

  • Upper half not autoclavable: Only the lower half is autoclavable; the upper assembly requires alternative cleaning methods, which may complicate complete sterilization.
  • Higher systematic error at low volumes: At 15 µL, the systematic error is ±4.00%, which may limit precision for small-volume applications compared to the mid-range performance.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).