Description
HiPette-LTS 12-channel 0.5-10 µL PipetteProduct Type: Fully autoclavable manual pipette
Research-grade liquid handling platform
|
|||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
|
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
This pipette requires autoclave sterilization for decontamination between uses. Calibration must follow ISO 8655-2 to maintain specified accuracy at the listed test volumes.
- Sterilization Requirement: The pipette must be fully disassembled and autoclaved at a validated temperature and cycle compatible with the polypropylene components to prevent deformation.
- Calibration Reference: Routine calibration should be performed according to ISO 8655-2 using the stated test volumes (10, 5, 1 µL) to verify systematic and random error remain within specified limits.
How does the systematic error of the HiPette-LTS 12-channel pipette vary across the 0.5–10 µL volume range?
The systematic error is specified at three test volumes (10, 5, and 1 µL) according to ISO 8655-2 calibration reference. Users can refer to the technical table for exact values at each volume. The pipette's 0.01 µL increment allows fine volume adjustments, but for optimal accuracy, it is recommended to operate near the upper end of the volume range.
What pipette tips are compatible with the HiPette-LTS 12-channel 0.5–10 µL pipette?
The manufacturer advises confirming compatible tips before ordering, as proper tip fit is critical for multichannel pipettes to ensure a tight seal and accurate liquid transfer. The product description does not specify a particular tip brand, so users should consult the technical table or contact the supplier for validated tip recommendations.
Can the HiPette-LTS 12-channel pipette be sterilized, and if so, what method is recommended?
Yes, the pipette is fully autoclavable, allowing for complete sterilization in an autoclave. The description does not specify exact cycle parameters, so users should follow standard autoclave protocols for manual pipettes and ensure the pipette is completely dry after sterilization.
This 12-channel manual pipette offers a 0.5-10 µL range with 0.01 µL increment, fully autoclavable for sterilization, with ISO 8655-2 calibration traceability. It is suited for high-throughput microplate and PCR workflows but requires compatible tips and regular calibration verification.
Positive
- Fully autoclavable without disassembly: The entire pipette can be autoclaved at 121°C, simplifying decontamination between assays or users without requiring disassembly.
- 12-channel parallel pipetting: Enables simultaneous transfer of 12 samples, significantly reducing handling time for microplate loading, PCR setup, and ELISA workflows.
Trade-offs
- Tip compatibility confirmation required: The pipette requires specific compatible tips; users must verify tip model and fit before ordering to ensure proper sealing and accuracy.
- Calibration dependency for accuracy: Systematic and random error are specified per test volume, and regular calibration per ISO 8655-2 is necessary to maintain documented accuracy, especially when switching between volumes.