Description
TopPette Single-channel 1000-10000 µL PipetteProduct Type: Manual pipette
Research-grade liquid handling platform
|
|||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
|
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
This manual pipette requires periodic calibration to ISO 8655-2 for accuracy verification. The lower half is autoclavable for sterilization, but tip compatibility must be confirmed before use.
- Calibration Requirement: Calibration must be validated against ISO 8655-2 using the stated test volumes to ensure compliance.
- Sterilization Procedure: Autoclave only the lower half of the pipette, as the upper assembly is not autoclavable.
- Tip Compatibility: Compatible tips must be confirmed prior to use to avoid leakage or inaccurate aspiration.
- Volume Range Restriction: Use only within the 1000-10000 µL range to maintain specified accuracy.
- Single-Channel Use: This pipette is designed for single-channel operation; do not use in multi-channel protocols.
How does the systematic error of the TopPette 1000-10000 µL pipette change across its volume range, and what does that mean for low-volume accuracy?
Systematic error increases from ±0.60% at 10000 µL to ±1.20% at 5000 µL and ±3.00% at 1000 µL. This means relative accuracy degrades significantly at lower volumes within the range, so users should plan calibrations or method validation accordingly for 1000 µL transfers.
Can the TopPette 1000-10000 µL pipette be used for PCR or qPCR setup, and what sterilization method is recommended?
Yes, it is suitable for PCR and qPCR setup as indicated in the overview. The lower half of the pipette is autoclavable where indicated, allowing sterilization of the parts that contact liquid. However, only the lower half is specified for autoclaving, so users should follow the manufacturer's instructions for sterilization of the entire pipette.
What calibration standard does the TopPette 1000-10000 µL pipette reference, and how should laboratory personnel manage calibration intervals?
The pipette is calibrated to ISO 8655-2, as indicated in the technical specifications, with systematic and random error values provided at three test volumes. Laboratories should establish a routine calibration schedule based on usage frequency and quality protocols, using the ISO standard for in-house verification.
The TopPette Single-channel 1000-10000 µL pipette delivers a wide volume range suited for macro-scale liquid handling, with lower-half autoclavability to reduce contamination risk. However, accuracy degrades significantly at the minimum test volume, and full sterilization of the instrument is not possible.
Positive
- Lower half autoclavable: The lower half of the pipette can be autoclaved where indicated, reducing cross-contamination risk during routine microbiological or PCR work.
- Large volume range with 100 µL increment: The 1000–10000 µL range and 100 µL increment support single-tube sample preparation, reagent addition, and serial dilution for macro-volume workflows.
Trade-offs
- Only lower half autoclavable: The upper half of the pipette is not autoclavable, limiting full sterilization of the instrument and requiring alternative decontamination methods for the handle and volume adjustment mechanism.
- Accuracy degrades at low volume: Systematic error increases to ±3.00% at 1000 µL compared to ±0.60% at 10000 µL, making the pipette less suitable for high-precision work near the lower end of its range.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).