Description
TopPette Single-channel 30-300 µL PipetteProduct Type: Manual pipette
Research-grade liquid handling platform
|
|||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
|
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
The pipette lower half is autoclavable at 121°C for 20 minutes; do not autoclave the upper assembly. Calibration must be verified per ISO 8655-2 and tips must be compatible with the 30-300 µL volume range.
- Partial Autoclavability: Only the lower half of the pipette can be autoclaved; the upper assembly must not be subjected to moist heat sterilization.
- Calibration Verification: Systematic and random error must be verified at 300 µL, 150 µL, and 30 µL using ISO 8655-2 reference method.
- Tip Selection: Use pipette tips certified for 30-300 µL volume range to maintain specified accuracy and prevent leakage or tip dropout.
How does the systematic error of the TopPette 30-300 µL pipette vary across its volume range?
The systematic error increases at lower volumes. At 300 µL it is ±1.80 µL (±0.6%), at 150 µL it is ±1.50 µL (±1.0%), and at 30 µL it is ±0.75 µL (±2.5%), as specified in the technical table.
What calibration standard does the TopPette 30-300 µL pipette conform to?
The pipette provides a user calibration reference according to ISO 8655-2, as stated in the technical specifications. Users should confirm calibration requirements and compatible tips before ordering.
Which parts of the TopPette 30-300 µL pipette can be sterilized by autoclaving?
The lower half of the pipette is autoclavable where indicated, as noted in the product description. The upper assembly is not specified for autoclaving, so users should verify sterilization suitability for their protocols.
The TopPette 30-300 µL manual pipette offers a single-channel format with a 0.2 µL increment and ISO 8655-2 calibration reference, suitable for routine liquid transfer and assay setup. Sterilization is limited to the lower half, and tip compatibility must be verified by the user.
Positive
- Single-channel precision for single-tube work: The single-channel configuration supports accurate liquid handling for single-tube sample preparation, reagent addition, serial dilution, and PCR/qPCR setup, ensuring repeatability in routine lab workflows.
- Autoclavable lower half for sterilization: The lower half of the pipette is autoclavable where indicated, allowing decontamination between uses to maintain sterility in sensitive applications.
Trade-offs
- Upper half not autoclavable: Only the lower half is autoclavable where indicated; the upper half cannot be heat-sterilized, requiring alternative disinfection methods for full decontamination.
- Tip compatibility and calibration must be confirmed: The product description states that users must confirm compatible tips, calibration requirements, and sterilization needs before ordering, adding an upfront validation step for lab integration.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).