Description
MicroPette Plus Single-channel 2000-20000 µL PipetteProduct Type: Fully autoclavable manual pipette
Research-grade liquid handling platform
|
|||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
|
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
The pipette must be calibrated at three test volumes per ISO 8655-2 and used with compatible tips to maintain specified systematic and random error limits. Full autoclave sterilization is supported, requiring adherence to standard decontamination cycles for laboratory equipment.
- Tip Compatibility: Use only tips designed for the 2000-20000 µL volume range to ensure secure fit and accurate pipetting.
- Calibration Requirements: Verify calibration at 2000, 10000, and 20000 µL test volumes using the systematic and random error specifications from the technical table.
- Sterilization Suitability: The pipette is fully autoclavable for decontamination; follow standard autoclaving cycles for laboratory equipment.
How does the systematic error of the MicroPette Plus 2000-20000 µL pipette vary across its volume range, and what are the implications for low-volume measurements?
The systematic error remains constant at ±120 µL for all test volumes (20000, 10000, and 2000 µL), but the relative error increases significantly from ±0.60% at 20000 µL to ±6.00% at 2000 µL. This means that while absolute error is fixed, percentage accuracy degrades sharply at the lower end of the range, so users should consider calibration adjustment or alternative methods for volumes near 2000 µL if high relative precision is required.
What calibration standard does the MicroPette Plus 2000-20000 µL pipette follow, and what must be verified before integrating it into a regulated laboratory workflow?
The pipette is calibrated per ISO 8655-2, as indicated in the technical specifications table. Before integration, users must confirm compatible tips, calibration requirements, and sterilization needs, as noted in the configuration support section of the product description. This ensures traceability for method setup and routine performance review in regulated environments.
What sterilization procedure is recommended for the MicroPette Plus 2000-20000 µL pipette, and are there any limitations on autoclave cycles?
The pipette is fully autoclavable, meaning it can be sterilized in an autoclave. However, the product description does not specify maximum autoclave cycles or post-sterilization handling requirements, so users should consult the manufacturer's instructions for cycle limits and proper procedures to maintain calibration accuracy.
The MicroPette Plus Single-channel 2000-20000 µL pipette provides fully autoclavable construction and ISO 8655-2 calibration traceability, but users must account for a 6% systematic error at the 2000 µL end and a 100 µL increment that limits fine volume resolution.
Positive
- Fully autoclavable sterilization: The entire pipette can be autoclaved at 121°C, enabling effective decontamination between uses and reducing cross-contamination risk in multi-user labs.
- ISO 8655-2 calibration reference: Systematic and random error values are reported per ISO 8655-2, providing a traceable baseline for user calibration verification and method validation.
Trade-offs
- High systematic error at low volume: At 2000 µL the systematic error is ±120 µL (±6.00%), which is substantially larger relative to the volume and may limit accuracy for applications requiring precise low-end dispensing.
- Coarse 100 µL increment: The 100 µL adjustment step constrains fine volume selection within the 2000–20000 µL range, making the pipette unsuitable for protocols requiring finer resolution.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).



