Single-Channel Manual Pipette 2-20 μL Mi-Pette ATOMFAIR®

$58.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Single-channel Mi-Pette manual pipette, 2-20 μL range with 0.02 μL increment, ISO 8655-2 calibration reference and autoclavable design. Order now.

SKU: AF-EI-L-MIPT-D020-SC00
Category: ,
Tags:
Brands:

Description

Mi-Pette Single-channel 2-20 µL Pipette

Product Type: Manual pipette
Research-grade liquid handling platform

Product Overview

Mi-Pette Single-channel 2-20 µL Pipette is a fully autoclavable manual pipette for accurate microliter liquid handling in research, quality-control and teaching laboratories. The 2-20 µL range supports single-tube sample preparation, reagent addition, serial dilution, PCR or qPCR setup and routine analytical transfer where repeatability, stable tip fit and traceable calibration data are important.

Select this model according to its single-channel format, 2-20 µL working range, 0.02 µL increment, compatible tips and sterilization requirements. The technical specifications list the order model, product family, test volumes, systematic error, random error and calibration reference for procurement, method setup and routine performance review.

Key Features and Advantages

  • Single-channel configuration for single-tube sample preparation, reagent addition, serial dilution, PCR or qPCR setup and routine analytical transfer.
  • Volume range 2-20 µL with 0.02 µL increment.
  • Sterilization suitability: High-temperature sterilization supported where indicated by source family.
  • Systematic error and random error values are listed by test volume for calibration review.
  • Suitable for routine liquid transfer, assay setup, sample preparation and laboratory training workflows.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-LH-MIPETTE-2-20-µL
Product Family Mi-Pette
Channel count Single-channel
Volume range 2-20 µL
Increment 0.02 µL
Test volume(s) 20 / 10 / 2 µL
Systematic error At 20 µL: ±0.2 µL (±1.0%); at 10 µL: ±0.2 µL (±2.0%); at 2 µL: ±0.2 µL (±10%)
Random error At 20 µL: ±0.1 µL (±0.5%); at 10 µL: ±0.1 µL (±1.0%); at 2 µL: ±0.1 µL (±5.0%)
Sterilization suitability High-temperature sterilization supported where indicated by source family
Calibration reference ISO 8655-2 user calibration reference indicated in the technical table
Technical table note Single-channel adjustable technical table
Configuration Support: Confirm compatible tips, calibration requirements, sterilization needs and laboratory workflow before ordering.
Technical Support: For method-specific volume matching, calibration planning, accessory compatibility or bulk laboratory configuration, contact the Atomfair technical sales team.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

This manual pipette requires periodic calibration according to ISO 8655-2 to maintain specified accuracy across the volume range. Sterilization compatibility depends on the specific unit variant and must be verified before high-temperature autoclaving.

  • Calibration Compliance: Periodic calibration according to ISO 8655-2 is required to maintain the specified accuracy across the volume range.
  • Sterilization Compatibility: High-temperature sterilization is only supported for specific unit variants; verify sterilization approval before autoclaving.
  • Tip Fit Requirement: Only tips designed for 2-20 µL pipettes with a secure seal should be used to prevent leakage and maintain accuracy.

How does the accuracy and precision of the Mi-Pette 2-20 µL change at the lower end of the volume range compared to the upper end?

At 20 µL, systematic error is ±0.2 µL (±1.0%) and random error is ±0.1 µL (±0.5%). At 2 µL, systematic error remains ±0.2 µL (±10%) and random error ±0.1 µL (±5%). While absolute error is constant, the percentage error increases dramatically at low volumes, making relative accuracy lower for 2 µL transfers than for 20 µL transfers.

What tip compatibility and calibration standards should be verified before using the Mi-Pette 2-20 µL in a regulated laboratory workflow?

The pipette is compatible with tips for the 2-20 µL range, and tip fit is critical for repeatability—confirm tips specifically for that volume range. The calibration reference is ISO 8655-2, so ensure that verification procedures follow that standard. The product description also notes that high-temperature sterilization is supported where indicated by the source family, so sterilization compatibility should be confirmed for the specific unit.

Can the Mi-Pette 2-20 µL be fully autoclaved for sterile applications, and what are the infrastructure requirements?

Yes, the Mi-Pette is described as a fully autoclavable manual pipette, and high-temperature sterilization is supported according to the source family. No specific temperature or cycle duration is provided in the source, so users should consult the manufacturer for validated autoclave parameters. No additional infrastructure beyond standard autoclave equipment is required.

The Mi-Pette Single-channel 2-20 µL pipette offers full autoclavability and ISO 8655-2 calibration traceability, but exhibits high relative systematic error (10%) at the 2 µL test volume, requiring careful volume selection for precision-sensitive applications.

Positive

  • Fully autoclavable without disassembly: The pipette can be sterilized at high temperature as indicated by source family, enabling straightforward decontamination between uses without requiring disassembly.
  • ISO 8655-2 calibration traceability: Systematic and random error values are listed per test volume with reference to ISO 8655-2, providing a documented calibration baseline for method validation and routine performance review.

Trade-offs

  • High systematic error at low volumes: At 2 µL the systematic error is ±0.2 µL (±10%), which limits accuracy for sub-5 µL transfers and may require volume selection above the lower end for precision-critical workflows.
  • External compatibility dependencies: Compatible tips and calibration requirements must be confirmed by the user; no tip brand or model is specified, and the pipette requires periodic user calibration to maintain stated performance.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).