Description
HiPette-LTS Single-channel 30-300 µL PipetteProduct Type: Fully autoclavable manual pipette
Research-grade liquid handling platform
|
|||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
|
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
This pipette requires periodic calibration per ISO 8655-2 to maintain specified accuracy. Compatible tips must be confirmed prior to use to ensure proper sealing and volume delivery.
- Sterilization: The pipette is fully autoclavable at 121°C for 20 minutes.
- Calibration: Calibration must be performed according to ISO 8655-2 using the indicated test volumes.
- Tip Compatibility: Only LTS-compatible tips should be used to ensure accurate volume delivery.
How does the accuracy of the HiPette-LTS 30-300 µL pipette vary between high and low test volumes, and what is the relative error trade-off?
At 300 µL, the systematic error is ±0.6% (1.8 µL) and random error is ±0.2% (0.6 µL); at 30 µL, systematic error increases to ±2.5% (0.75 µL) and random error to ±0.7% (0.21 µL). This indicates that the pipette delivers best relative accuracy at the upper end of its range, while lower volumes show higher percentage error, a typical trade-off for adjustable-volume pipettes.
Does the fully autoclavable design of the HiPette-LTS pipette make it suitable for PCR and qPCR workflows?
Yes, the pipette is fully autoclavable, enabling sterilization before use in PCR or qPCR setup. The product description explicitly lists 'PCR or qPCR setup' as a key application, and the ability to autoclave helps prevent cross-contamination and nuclease degradation of nucleic acid samples.
What calibration standard does the HiPette-LTS 30-300 µL pipette follow, and how can users verify its accuracy?
The pipette is calibrated to ISO 8655-2, with systematic and random error values provided at the test volumes of 300, 150, and 30 µL. These values serve as acceptance criteria for user calibration verification, as indicated in the technical table and calibration reference.
The HiPette-LTS 30-300 µL single-channel pipette offers fully autoclavable construction and ISO 8655-2 traceable accuracy, with systematic error ranging from ±0.6% at 300 µL to ±2.5% at 30 µL, making it suitable for routine liquid handling where sterilization and calibration documentation are required.
Positive
- Fully autoclavable for aseptic workflows: The entire pipette can be sterilized by autoclaving, enabling use in PCR setup, cell culture, and other contamination-sensitive applications without disassembly.
- ISO 8655-2 traceable error specifications: Systematic and random errors are provided at three test volumes (300, 150, 30 µL) with reference to ISO 8655-2, allowing direct calibration verification and method validation.
Trade-offs
- Higher systematic error at low end: At 30 µL the systematic error is ±2.5% (±0.75 µL), which may limit accuracy for sub-50 µL quantitative transfers compared to pipettes optimized for lower volumes.
- Tip compatibility and calibration dependency: Optimal performance requires compatible tips and periodic calibration verification; the user must confirm tip fit and calibration schedule before deployment in regulated workflows.