HiPette-LTS Single-channel 30-300 µL Pipette

Product Type: Fully autoclavable manual pipette
Research-grade liquid handling platform

Product Overview

HiPette-LTS Single-channel 30-300 µL Pipette is a fully autoclavable manual pipette for accurate microliter liquid handling in research, quality-control and teaching laboratories. The 30-300 µL range supports single-tube sample preparation, reagent addition, serial dilution, PCR or qPCR setup and routine analytical transfer where repeatability, stable tip fit and traceable calibration data are important.

Select this model according to its single-channel format, 30-300 µL working range, 0.2 µL increment, compatible tips and sterilization requirements. The technical specifications list the order model, product family, test volumes, systematic error, random error and calibration reference for procurement, method setup and routine performance review.

Key Features and Advantages

  • Single-channel configuration for single-tube sample preparation, reagent addition, serial dilution, PCR or qPCR setup and routine analytical transfer.
  • Volume range 30-300 µL with 0.2 µL increment.
  • Sterilization suitability: Fully autoclavable.
  • Systematic error and random error values are listed by test volume for calibration review.
  • Suitable for routine liquid transfer, assay setup, sample preparation and laboratory training workflows.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-LH-HIPETTE-LTS-30-300-µL
Product Family HiPette-LTS
Channel count Single-channel
Volume range 30-300 µL
Increment 0.2 µL
Test volume(s) 300 / 150 / 30 µL
Systematic error At 300 µL: ±1.80 µL (±0.6%); at 150 µL: ±1.50 µL (±1.0%); at 30 µL: ±0.75 µL (±2.5%)
Random error At 300 µL: ±0.60 µL (±0.2%); at 150 µL: ±0.45 µL (±0.3%); at 30 µL: ±0.21 µL (±0.7%)
Sterilization suitability Fully autoclavable
Calibration reference ISO 8655-2 user calibration reference indicated in the technical table
Technical table note Single-channel adjustable technical table
Configuration Support: Confirm compatible tips, calibration requirements, sterilization needs and laboratory workflow before ordering.
Technical Support: For method-specific volume matching, calibration planning, accessory compatibility or bulk laboratory configuration, contact the Atomfair technical sales team.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

This pipette requires periodic calibration per ISO 8655-2 to maintain specified accuracy. Compatible tips must be confirmed prior to use to ensure proper sealing and volume delivery.

  • Sterilization: The pipette is fully autoclavable at 121°C for 20 minutes.
  • Calibration: Calibration must be performed according to ISO 8655-2 using the indicated test volumes.
  • Tip Compatibility: Only LTS-compatible tips should be used to ensure accurate volume delivery.

How does the accuracy of the HiPette-LTS 30-300 µL pipette vary between high and low test volumes, and what is the relative error trade-off?

At 300 µL, the systematic error is ±0.6% (1.8 µL) and random error is ±0.2% (0.6 µL); at 30 µL, systematic error increases to ±2.5% (0.75 µL) and random error to ±0.7% (0.21 µL). This indicates that the pipette delivers best relative accuracy at the upper end of its range, while lower volumes show higher percentage error, a typical trade-off for adjustable-volume pipettes.

Does the fully autoclavable design of the HiPette-LTS pipette make it suitable for PCR and qPCR workflows?

Yes, the pipette is fully autoclavable, enabling sterilization before use in PCR or qPCR setup. The product description explicitly lists 'PCR or qPCR setup' as a key application, and the ability to autoclave helps prevent cross-contamination and nuclease degradation of nucleic acid samples.

What calibration standard does the HiPette-LTS 30-300 µL pipette follow, and how can users verify its accuracy?

The pipette is calibrated to ISO 8655-2, with systematic and random error values provided at the test volumes of 300, 150, and 30 µL. These values serve as acceptance criteria for user calibration verification, as indicated in the technical table and calibration reference.

The HiPette-LTS 30-300 µL single-channel pipette offers fully autoclavable construction and ISO 8655-2 traceable accuracy, with systematic error ranging from ±0.6% at 300 µL to ±2.5% at 30 µL, making it suitable for routine liquid handling where sterilization and calibration documentation are required.

Positive

  • Fully autoclavable for aseptic workflows: The entire pipette can be sterilized by autoclaving, enabling use in PCR setup, cell culture, and other contamination-sensitive applications without disassembly.
  • ISO 8655-2 traceable error specifications: Systematic and random errors are provided at three test volumes (300, 150, 30 µL) with reference to ISO 8655-2, allowing direct calibration verification and method validation.

Trade-offs

  • Higher systematic error at low end: At 30 µL the systematic error is ±2.5% (±0.75 µL), which may limit accuracy for sub-50 µL quantitative transfers compared to pipettes optimized for lower volumes.
  • Tip compatibility and calibration dependency: Optimal performance requires compatible tips and periodic calibration verification; the user must confirm tip fit and calibration schedule before deployment in regulated workflows.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).