This document specifies the operational constraints for the tungsten evaporation boat. It includes temperature limits, electrical rating, and geometry compatibility requirements.
- Temperature Limit: The boat must not be operated above its maximum temperature rating of 1200 °C.
- Electrical Rating: The boat requires a power supply that matches the rated voltage of 1.47 V, current of 204 A, and power of 300 W.
- Geometry Compatibility: The boat's dimensions and tub geometry must be confirmed against the evaporation source holder before installation.
- Tub Capacity: The 2 cc tub capacity determines the maximum source loading volume for the evaporation process.
Steps to confirm the boat's compatibility with the evaporation system before use. Verify geometry, electrical ratings, and temperature limits.
Required Equipment: Evaporation source holder, Resistive-heating power supply
- Confirm geometry
Confirm the boat material, overall dimensions, tub geometry, and tub capacity against the selected evaporation source holder. - Match electrical ratings
Match the voltage, current, and power values with the resistive-heating power supply capability. - Verify temperature limit
Verify that the maximum temperature rating of 1200 °C is suitable for the evaporation process.
How do the voltage, current, and power ratings of 1.47 V, 204 A, and 300 W affect the heating performance and compatibility with resistive-heating power supplies for this tungsten evaporation boat?
The boat is rated at 1.47 V, 204 A, and 300 W, which define its resistive-heating profile for vacuum evaporation. These values must be matched exactly to the power supply to achieve the 1200 °C maximum temperature; exceeding them can cause overheating or failure. The electrical rating is a critical parameter for power-supply configuration before order.
What are the critical dimensional constraints for integrating this flat-tub step-type tungsten boat into a vacuum evaporation system?
The boat has overall dimensions of 0.3 mm thickness, 16 mm width, and 100 mm length, with a tub length of 50 mm, depth of 3.8 mm, and capacity of 2 cc. The flat-tub geometry with down step 11,2 requires matching the evaporation source holder's contacts and cavity. All dimensions must be confirmed against the holder before installation.
What is the significance of the 'down step 11,2' specification in the flat-tub geometry of this tungsten evaporation boat?
The 'down step 11,2' describes a specific step dimension (likely 11.2 mm) that defines the transition from the boat body to the flat tub region. This feature is essential for proper seating in the source holder and ensures uniform current distribution across the boat during resistive heating, directly impacting evaporation consistency.
Tungsten evaporation boat with step-type flat tub geometry, 0.3x16x100 mm dimensions, 2 cc tub capacity, 1200°C max temperature, and specified electrical ratings for resistive-heating vacuum evaporation. Requires careful matching with source holder and power supply.
Positive
- Tungsten construction with defined geometry: Tungsten material is selected for resistive-heating source configuration, and the defined boat geometry (0.3 mm thickness, 16 mm width, 100 mm length) supports dimensional matching before installation.
- Clear electrical and temperature ratings: Electrical rating (1.47 V, 204 A, 300 W) and maximum temperature (1200 °C) provide configuration values for power-supply review and temperature-limit matching with the evaporation process.
Trade-offs
- Requires dimensional and geometry matching: Boat material, overall dimensions, tub geometry, and tub capacity must be confirmed against the selected evaporation source holder before installation.
- Electrical rating must match power supply: Voltage, current, and power values must be matched with the available resistive-heating power supply before ordering to ensure compatibility.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).