Thin-Film Cell Holder 1 mm, 10×30 mm Window ATOMFAIR®

$87.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Research-grade thin-film cell holder with 1 mm thickness and 10×30 mm window for SpectraCore UV 3101/3102/5101/5102 spectrophotometers. Order now.

SKU: AF-EI-A-CELL-THFL-1M08
Category:
Tags: , ,
Brands:

Description

Thin-film cell holder 1 mm

Product Type: Spectrophotometer Sample Holder Accessory
Research-grade laboratory product

Product Overview

Spectrophotometer Sample Holder Accessory with Thin-film cell holder 1 mm and Thickness 1 mm; 10 x 30 mm window supports spectrophotometer sample handling, optical-path selection, lamp replacement or verification workflows.

Select the accessory by reference code, optical path length, holder geometry and compatible spectrophotometer series before quotation.

Performance Features

  • Thin-film cell holder 1 mm defines the accessory type for spectrophotometer configuration.
  • Specification of Thickness 1 mm; 10 x 30 mm window supports sample-path or verification matching.
  • Compatibility or use case: SpectraCore UV 3101 / SpectraCore UV 3102 / SpectraCore UV 5101 / SpectraCore UV 5102.
  • Reference code 18901008 supports procurement confirmation.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-TF1MM08
Accessory name Thin-film cell holder 1 mm
Reference code 18901008
Specification Thickness 1 mm; 10 x 30 mm window
Compatibility / use SpectraCore UV 3101 / SpectraCore UV 3102 / SpectraCore UV 5101 / SpectraCore UV 5102

Selection and Use Notes

  • Confirm wavelength range, bandwidth, optical system and sample holder format before quotation.
  • Confirm accessory compatibility, optical path length, reference code and measurement workflow when ordering holders, lamps, filters or standards.
PROCUREMENT CHECK: Confirm model, working range, compatibility, consumables and required configuration before quotation.
DOCUMENTATION REVIEW: Product specifications and configuration details are reviewed against laboratory use requirements.
ACCESSORY MATCHING: Compatible accessories, replacement parts and consumables can be matched according to the selected configuration.
RFQ NOTE: Include the required model, configuration and quantity when requesting quotation support.
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, platform compatibility or configuration confirmation, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

This accessory is compatible only with SpectraCore UV 3101, 3102, 5101, and 5102 spectrophotometers. Optical path length, holder geometry, and reference code must be confirmed before use.

  • Compatibility: The holder is designed for the listed SpectraCore UV models and may not fit other spectrophotometers.
  • Configuration Validation: Wavelength range, bandwidth, and optical system must be verified prior to ordering.
  • Measurement Workflow: Accessory compatibility, optical path length, and reference code must be confirmed when ordering.
  • Procurement Check: Model, working range, compatibility, and required configuration must be reviewed before quotation.
  • Documentation Review: Product specifications and configuration details should be reviewed against laboratory requirements.

What is the impact of the fixed 1 mm path length on the measurement of thin films with varying optical density?

The holder has a fixed thickness of 1 mm and a 10×30 mm window, which defines a constant optical path length. For thin films with low optical density, this short path may require careful selection of wavelength range and detector sensitivity; the product confirms that users should verify wavelength range and optical system before quotation.

Which specific SpectraCore UV spectrophotometer models are compatible with this holder, and what configuration checks are needed?

The holder is compatible with SpectraCore UV 3101, UV 3102, UV 5101, and UV 5102 models. Before use, users must confirm the optical path length (1 mm), reference code (18901008), and sample holder format compatibility.

Is the Thin-film cell holder 1 mm suitable for use in lamp replacement or optical path verification workflows?

According to the product overview, the holder supports lamp replacement or verification workflows in addition to sample handling. It is a spectrophotometer accessory intended for use with SpectraCore UV series, so it can be employed in these procedures if the optical system and holder format are confirmed.

The Thin-film cell holder 1 mm (AF-TF1MM08) is a precision accessory for SpectraCore UV spectrophotometers (3101/3102/5101/5102), featuring a 1 mm thickness and 10 x 30 mm window for thin-film spectroscopy. It requires careful pre-order compatibility confirmation with the host instrument's optical configuration and is limited to 1 mm cell thicknesses.

Positive

  • Precise thin-film optical path geometry: The 1 mm thickness and 10 x 30 mm window provide a defined optical path for accurate thin-film absorption or transmission measurements.
  • Broad compatibility with SpectraCore UV series: Compatible with SpectraCore UV 3101, 3102, 5101, and 5102 spectrophotometers, offering flexibility across multiple instrument models from the same manufacturer.

Trade-offs

  • Pre-order compatibility verification required: Users must confirm wavelength range, bandwidth, optical system, and sample holder format with their specific SpectraCore model before purchase to ensure proper fit and function.
  • Exclusive to 1 mm thin-film cells: The holder is designed specifically for cells with 1 mm thickness; it cannot accommodate cells of different thicknesses without purchasing a different holder.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).