Straight Titanium Electrode Clip <3mm 6mm Rod ATOMFAIR®

$59.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Research-grade straight titanium electrode clip with 6mm rod, one-piece construction, and replaceable contact for flat sheet samples <3mm. Order now.

SKU: AF-EC-C-TICL-TITN-STR1
Category:
Brands:

Straight Titanium Electrode Clip | ATOMFAIR

RESEARCH GRADE INSTRUMENT

Product Overview

The ATOMFAIR® Straight Titanium Electrode Clip features a straight, in-line design where the clip head and connecting rod are aligned on the same axis, providing easy access to flat sheet working electrodes in conventional electrochemical cells. Precision-machined from a single block of high-grade titanium (one-piece solid-block precision machining), the clip ensures structural integrity, mechanical strength, and consistent performance. The sample contact region is replaceable, extending the service life of the overall assembly. The titanium construction offers excellent corrosion resistance, making it suitable for aggressive electrolytes, while providing outstanding electrical conductivity for accurate electrochemical measurements. This electrode clip is specifically designed to securely hold flat sheet samples with a thickness of less than 3mm. A 6mm diameter connecting rod ensures compatibility with standard electrode holders.

Technical Specifications

PARAMETER DETAILS
Core Device & Design
Device Type Straight in-line electrode clip for flat sheet samples (thickness < 3mm)
Conductive Contact Material High-grade titanium
Connecting Rod Diameter 6mm
Connecting Rod Material High-grade titanium (integral, one-piece construction)


Key Features & Advantages

  • One-Piece Solid-Block Machining: Fabricated from a single block of titanium, the clip delivers consistent geometry, superior mechanical strength, and reliable clamping pressure without loose components.
  • Replaceable Sample Contact Region: The sample contact area can be replaced when worn, significantly extending the useful life of the electrode clip assembly.
  • Excellent Corrosion Resistance: The titanium construction provides outstanding corrosion resistance, making the clip suitable for use even in aggressive electrolytes.
  • Outstanding Electrical Conductivity: Ensures a low-resistance electrical path to the working electrode for accurate and reliable electrochemical measurements.
  • High-Grade Titanium Construction: Offers light weight, excellent mechanical strength, and inherent biocompatibility for bio-industry and healthcare applications.

APPLICATION SCOPE: Healthcare, Environmental Monitoring, Chemical Engineering, Bio-industry, and Advanced Energy Systems.
PACKAGING: Secure individual research-grade protective containers with shock-absorption parameters.
IMPORTANT NOTICE: This product is highly sensitive to surface contamination. Keep containers tightly sealed or handle exclusively within an anhydrous inert environment to prevent phase contamination or degradation before electrochemical validation.
TAILORED SOLUTIONS FOR RESEARCH
Contact our engineering team for technical support or official institutional quotations.
EMAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

The titanium electrode clip is highly sensitive to surface contamination, which can compromise electrochemical measurements. Storage must be in sealed containers or within an anhydrous inert environment to prevent phase contamination or degradation before use.

  • Surface Contamination Sensitivity: Keep containers tightly sealed or handle exclusively within an anhydrous inert environment to prevent phase contamination or degradation before electrochemical validation.

Secure the electrode clip to a flat sheet sample under 3 mm thick for electrochemical testing. Maintain a contamination-free environment to ensure accurate measurements.

Required Equipment: Anhydrous inert environment (e.g., glovebox), Standard electrode holder (6 mm diameter compatible)

  1. Inspect the clip
    Inspect the titanium contact region and connecting rod for cleanliness or damage before use.
  2. Prepare the sample
    Confirm the flat sheet sample thickness is less than 3 mm and clean the sample surface if required.
  3. Mount the clip
    Insert the flat sheet sample into the clip head, ensuring secure and uniform contact pressure.
  4. Connect the electrode assembly
    Attach the 6 mm connecting rod to a standard electrode holder within the anhydrous inert environment.
  5. Verify electrical continuity
    Measure resistance across the clip and sample to confirm a low-impedance electrical path before use.

What is the maximum thickness of flat sheet samples that can be used with the ATOMFAIR straight titanium electrode clip?

The clip is specifically designed to securely hold flat sheet samples with a thickness of less than 3mm, as stated in the technical specifications. This ensures reliable clamping pressure and electrical contact for accurate electrochemical measurements.

Does the 6mm connecting rod of the titanium electrode clip fit standard electrode holders?

Yes, the 6mm diameter connecting rod ensures compatibility with standard electrode holders commonly used in electrochemical cells. The one-piece titanium construction provides a low-resistance electrical path and corrosion resistance for aggressive electrolytes.

What storage and handling precautions are required for the ATOMFAIR titanium electrode clip?

The product is highly sensitive to surface contamination, so it must be kept in tightly sealed containers or handled exclusively within an anhydrous inert environment to prevent degradation before electrochemical validation. Individual research-grade protective containers with shock-absorption parameters are provided to ensure safe storage and transport.

The ATOMFAIR Straight Titanium Electrode Clip (SKU: AF-EC-C-TICL-TITN-STR1) is a one-piece machined titanium electrode holder designed for flat sheet samples under 3 mm thickness, offering corrosion resistance and a replaceable contact region for extended service life in aggressive electrolyte environments.

Positive

  • One-piece titanium construction: Precision-machined from a single block of high-grade titanium, the clip provides superior mechanical strength and consistent geometry without loose components, ensuring reliable clamping pressure and structural integrity during electrochemical measurements.
  • Replaceable sample contact region: The sample contact area is replaceable, significantly extending the useful life of the electrode clip assembly and reducing long-term replacement costs in repeated-use laboratory settings.

Trade-offs

  • Surface contamination sensitivity: The product is highly sensitive to surface contamination; it requires storage in tightly sealed containers or handling within an anhydrous inert environment to prevent degradation before electrochemical validation, adding pre-use preparation steps.
  • Limited sample thickness range: The clip is specifically designed for flat sheet samples with a thickness of less than 3 mm, restricting its application to thin substrates and excluding thicker or irregularly shaped working electrodes.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).