EB82G-01MG-R-02 Semi-Micro Balance 82g 0.01mg ATOMFAIR®

$1,366.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Semi-micro balance with 82 g/120 g dual range, 0.01/0.1 mg readability, internal isbl calibration, RS232, and ≤5 s stabilization. Order now.

SKU: AF-EI-B-SMBL-120U-IR02
Category:
Brands:

ATOMFAIR® EB82G-01MG-R-02 ANALYTICAL & SEMI-MICRO BALANCE

EB82G-01MG-R-02 CORE SPECIFICATION PLATFORM

Product Overview

The ATOMFAIR® EB82G-01MG-R-02 is an analytical & semi-micro balance configured for High-accuracy industrial laboratory analysis, analytical chemistry, with 82 g maximum capacity and 0.01 mg readability. It delivers ±0.02 mg linearity, range semi-micro balance with internal isbl calibration.
Built with an electromagnetic force sensor, it supports precision weighing control for the stated measurement range. Its calibration configuration is range semi-micro balance with internal isbl calibration, supporting the calibration workflow for this model. The stated stabilization performance is ≤5 seconds, giving the operator a defined response-time reference before recording measurements.
Its split-body structural architecture and glass draft shield help support stable weighing performance. The communication configuration includes a standard RS232 communication interface. The stated application scope covers High-accuracy industrial laboratory analysis, analytical chemistry, premium material research, and dual-range core verification workflows.

EB82G-01MG-R-02 Target Model Specification Matrix

PARAMETER ITEM DETAILED MEASUREMENT PROFILE
1. Calibration & Metrology Parameters
Calibration Configuration Internal Automated Calibration Variant (isbl Integrated System)
Readability Division Value 0.01 mg / 0.1 mg (Automated Dual Range Matrix)
Maximum Scale Capacity 82 g / 120 g (Dual-Range Fluctuating)
Standard Repeatability Deviation ±0.02 mg / ±0.1 mg
Linearity Distortion Error ±0.02 mg / ±0.1 mg
Average Stabilization Response Time ≤ 5 Seconds
Mandatory Preheating Threshold 30 ~ 60 Minutes Following Power-on Initialization
2. Geometric Metrics & Volumetric Footprint
Weighing Pan Dimensions Φ 90 mm
Outer Structural Dimensions 410 mm × 310 mm × 320 mm
Effective Draft Shield Height 230 mm
Internal Weighing Chamber Size 195 mm × 100 mm
3. Environmental Constraints & Electrical Architecture
Operating Environmental Temperature 10°C ~ 33°C
Operating Workspace Humidity 20% ~ 80% RH
Power Subsystem Profiles Global Matrix Compliance Interface | Input: 220V AC / 50Hz | Output: 12V DC / 2A

ES Series Comprehensive Portfolio Comparison Matrix

SPECIFICATION ITEM EB31G-01MG-R-01 EB51G-01MG-R-01 EB82G-01MG-R-01 EB31G-01MG-R-02 EB51G-01MG-R-02 EB82G-01MG-R-02 EB82G-01MG-R-02
Readability Value (mg) 0.01/0.1 0.01/0.1 0.01/0.1 0.01/0.1 0.01/0.1 0.01/0.1 0.01/0.1
Max Capacity Threshold (g) 31/120 51/120 82/120 31/120 51/120 82/120 120
Repeatability Dev. (mg) ±0.02/0.1 ±0.02/0.1 ±0.02/0.1 ±0.02/0.1 ±0.02/0.1 ±0.02/0.1 ±0.02/0.1
Linearity Error Max (±mg) ±0.02/0.1 ±0.02/0.1 ±0.02/0.1 ±0.02/0.1 ±0.02/0.1 ±0.02/0.1 ±0.02/0.1
Stabilization Target (s) ≤ 5 Seconds (All Models Equipped)
Warm-up Duration Threshold 30 ~ 60 Minutes Required
Weighing Pan / Chassis Pan: Φ 90 mm | Outer Matrix: 410 × 310 × 320 mm | Shield Height: 230 mm | Chamber Size: 195 × 100 mm
Environment Requirements Temp Threshold: 10°C ~ 33°C | Humidity Workspace Range: 20% ~ 80% RH
Power Subsystem Profiles Global Matrix Compliance Interface | Input: 220V AC / 50Hz | Output: 12V DC / 2A (All Models Shared)

Full Series Core Functional Advantages

  • Split-Body Structural Architecture: Detached control display unit isolates hand-induced micro-vibrations from the balance baseline chassis, allowing real-time data inspection from multiple flexible angles.
  • Transparent Panoramic Glass Draft Shield: Provides all-around panoramic visibility of weighing specimens with quick-release mechanics for rapid disassembly and efficient decontamination.
  • Rear-Mounted Electromagnetic Force Sensor: Premium-tier high-accuracy internal balance core ensures outstanding repeatability, stable readings, and fast response kinetics.
  • Extendable & Adjusting LED Display Panel: Features an ultra-bright layout that allows operators to seamlessly adjust the display tilt angle for zero-parallax reading verification.
  • Versatile Operational Weighing Modes: Supports robust native processing for standard foundational weight measurement, percentage balance determination, and precise parts tracking/piece counting workflows.
  • Instantaneous Multi-Unit Conversions: Enables single-key toggle transitions between international mass dimensions including grams (g), carats (ct), ounces (oz), and pounds (lb) with zero manual math.
  • Optimized Trace Micro-Addition Processing: Driven by advanced digital signal processing firmware, the system maintains rock-solid readouts with zero baseline drift, micro-capturing minute sample additions with high fidelity.
  • Integrated RS232 Communication Bus: Bidirectional port supports direct data pipelines to micro-printers and host computer terminals, enabling automated data logging and paperless compliance tracking.
  • Autonomous Fully Automatic isbl Calibration: Executes automated internal balancing calibration if ambient workspace temperature fluctuates by ≥1.5°C or if time elapsed exceeds 2 hours. Supports manual override.

APPLICATION SCOPE: High-accuracy industrial laboratory analysis, analytical chemistry, premium material research, and dual-range core verification workflows.
HIGH-EFFICIENCY HARNESS: Cost-effective design architectures highly optimized for analytical research institutes and institutional compliance laboratories.
IMPORTANT NOTICE: To preserve uncompromised reading precision and maintain sensor linearity, allow an initial warm-up threshold of 30-60 minutes following power engagement before performing operational zeroing, internal calibration, or sample addition.
TAILORED INDUSTRIAL LAB SOLUTIONS
Contact our elite laboratory engineering team for institutional bulk procurement quotes or interface custom integration.
EMAIL: INQUIRY@ATOMFAIR.COM
MANUFACTURER OPERATIONS: ATOMFAIR LLC INSTRUMENTS DIVISION
REGISTERED BRAND: ATOMFAIR®

The balance requires an operating temperature of 10°C to 33°C and humidity between 20% and 80% RH to maintain specified accuracy. A mandatory warm-up period of 30 to 60 minutes is required after power-on before zeroing, calibration, or sample addition.

  • Environmental Conditions: Operating temperature must remain between 10°C and 33°C and humidity between 20% and 80% RH to prevent drift or error.
  • Warm-up Requirement: Allow the balance to warm up for 30 to 60 minutes after power-on before performing zeroing, internal calibration, or sample addition.
  • Calibration Triggers: The internal isbl calibration automatically executes when ambient temperature changes by ≥1.5°C or after 2 hours of operation.
  • Stabilization Time: Wait at least 5 seconds after sample placement for the reading to stabilize before recording.
  • Vibration Isolation: The split-body design isolates hand-induced micro-vibrations from the weighing base; avoid touching the base during measurement.

This balance provides high-accuracy weighing with 0.01 mg readability and internal automated calibration. Follow these steps to ensure precise measurements and proper operation.

Required Equipment: Glass draft shield, Internal calibration system (ISBL)

  1. Warm-up the balance
    Allow the balance to warm up for 30 to 60 minutes after power-on before any operation.
  2. Verify environmental conditions
    Verify that the ambient temperature is between 10°C and 33°C and humidity between 20% and 80% RH.
  3. Perform zeroing
    Press the tare or zero key to zero the balance after warm-up and before calibration or sample addition.
  4. Initiate internal calibration
    Initiate manual internal calibration if the automatic trigger has not occurred or if required by protocol.
  5. Place sample and record reading
    Place the sample on the weighing pan, close the draft shield, and wait for the stabilization indicator before recording the weight.

How does the dual-range readability (0.01 mg vs 0.1 mg) affect measurement accuracy and capacity on the EB82G-01MG-R-02?

The EB82G-01MG-R-02 offers an automated dual-range matrix with readability of 0.01 mg and 0.1 mg, corresponding to maximum capacities of 82 g and 120 g respectively. The 0.01 mg range provides higher resolution for smaller samples up to 82 g, while the 0.1 mg range extends capacity to 120 g with lower resolution. This allows the user to select the optimal balance between precision and capacity for their specific application.

What are the warm-up and calibration requirements for the EB82G-01MG-R-02 to ensure measurement accuracy?

The balance requires a mandatory preheating threshold of 30 to 60 minutes following power-on initialization before performing operational zeroing, internal calibration, or sample addition. It features autonomous fully automatic isbl calibration that executes if ambient temperature fluctuates by ≥1.5°C or if time elapsed exceeds 2 hours, with manual override available.

Can the EB82G-01MG-R-02 be integrated with external data systems for automated data logging?

Yes, the balance is equipped with a standard RS232 communication interface that supports bidirectional data pipelines to micro-printers and host computer terminals, enabling automated data logging and paperless compliance tracking.

The ATOMFAIR EB82G-01MG-R-02 analytical semi-micro balance delivers 0.01 mg readability and 82 g capacity with dual-range flexibility to 120 g, internal automated calibration, and a split-body design that isolates vibration, but requires a 30–60 minute warm-up and controlled environmental conditions (10–33°C, 20–80% RH) for rated performance.

Positive

  • Internal Automated Calibration (isbl): The balance autonomously recalibrates when ambient temperature changes by ≥1.5°C or after 2 hours, ensuring long-term accuracy without manual intervention.
  • Split-Body Vibration Isolation: The detached control display unit isolates hand-induced micro-vibrations from the base chassis, improving measurement stability in sensitive analytical workflows.

Trade-offs

  • Mandatory Warm-Up Period: A 30–60 minute power-on stabilization period is required before calibration or sample measurement to achieve specified linearity and repeatability.
  • Environmental Sensitivity Constraints: The balance requires controlled laboratory conditions (10–33°C, 20–80% RH) and a 220V AC/50Hz power supply, limiting deployment in non-standard facilities.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.