Analytical Semi-Micro Balance 51/120g 0.01mg ATOMFAIR®

$1,146.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Internal-calibration analytical semi-micro balance with 51/120 g dual range, 0.01/0.1 mg readability, ±0.02 mg linearity, RS232, and Φ90 mm pan. Order now.

SKU: AF-EI-B-SMBL-120U-IR03
Category:
Brands:

ATOMFAIR® EB51G-01MG-R-02 ANALYTICAL & SEMI-MICRO BALANCE

EB51G-01MG-R-02 CORE SPECIFICATION PLATFORM

Product Overview

The ATOMFAIR® EB51G-01MG-R-02 is an analytical & semi-micro balance configured for High-accuracy industrial laboratory analysis, analytical chemistry, with 51 g maximum capacity and 0.01 mg readability. It delivers ±0.02 mg linearity, internal isbl calibration.
Built with an electromagnetic force sensor, it supports precision weighing control for the stated measurement range. Its calibration configuration is internal isbl calibration, supporting the calibration workflow for this model. The stated stabilization performance is ≤5 seconds, giving the operator a defined response-time reference before recording measurements.
Its split-body structural architecture and glass draft shield help support stable weighing performance. The communication configuration includes a standard RS232 communication interface. The stated application scope covers High-accuracy industrial laboratory analysis, analytical chemistry, premium material research, and dual-range core verification workflows.

EB51G-01MG-R-02 Target Model Specification Matrix

PARAMETER ITEM DETAILED MEASUREMENT PROFILE
1. Calibration & Metrology Parameters
Calibration Configuration Internal Automated Calibration Variant (isbl Integrated System)
Readability Division Value 0.01 mg / 0.1 mg (Automated Dual Range Matrix)
Maximum Scale Capacity 51 g / 120 g (Dual-Range Fluctuating)
Standard Repeatability Deviation ±0.02 mg / ±0.1 mg
Linearity Distortion Error ±0.02 mg / ±0.1 mg
Average Stabilization Response Time ≤ 5 Seconds
Mandatory Preheating Threshold 30 ~ 60 Minutes Following Power-on Initialization
2. Geometric Metrics & Volumetric Footprint
Weighing Pan Dimensions Φ 90 mm
Outer Structural Dimensions 410 mm × 310 mm × 320 mm
Effective Draft Shield Height 230 mm
Internal Weighing Chamber Size 195 mm × 100 mm
3. Environmental Constraints & Electrical Architecture
Operating Environmental Temperature 10°C ~ 33°C
Operating Workspace Humidity 20% ~ 80% RH
Power Subsystem Profiles Global Matrix Compliance Interface | Input: 220V AC / 50Hz | Output: 12V DC / 2A

ES Series Comprehensive Portfolio Comparison Matrix

SPECIFICATION ITEM EB31G-01MG-R-01 EB51G-01MG-R-01 EB82G-01MG-R-01 EB31G-01MG-R-02 EB51G-01MG-R-02 EB82G-01MG-R-02 EB82G-01MG-R-02
Readability Value (mg) 0.01/0.1 0.01/0.1 0.01/0.1 0.01/0.1 0.01/0.1 0.01/0.1 0.01/0.1
Max Capacity Threshold (g) 31/120 51/120 82/120 31/120 51/120 82/120 120
Repeatability Dev. (mg) ±0.02/0.1 ±0.02/0.1 ±0.02/0.1 ±0.02/0.1 ±0.02/0.1 ±0.02/0.1 ±0.02/0.1
Linearity Error Max (±mg) ±0.02/0.1 ±0.02/0.1 ±0.02/0.1 ±0.02/0.1 ±0.02/0.1 ±0.02/0.1 ±0.02/0.1
Stabilization Target (s) ≤ 5 Seconds (All Models Equipped)
Warm-up Duration Threshold 30 ~ 60 Minutes Required
Weighing Pan / Chassis Pan: Φ 90 mm | Outer Matrix: 410 × 310 × 320 mm | Shield Height: 230 mm | Chamber Size: 195 × 100 mm
Environment Requirements Temp Threshold: 10°C ~ 33°C | Humidity Workspace Range: 20% ~ 80% RH
Power Subsystem Profiles Global Matrix Compliance Interface | Input: 220V AC / 50Hz | Output: 12V DC / 2A (All Models Shared)

Full Series Core Functional Advantages

  • Split-Body Structural Architecture: Detached control display unit isolates hand-induced micro-vibrations from the balance baseline chassis, allowing real-time data inspection from multiple flexible angles.
  • Transparent Panoramic Glass Draft Shield: Provides all-around panoramic visibility of weighing specimens with quick-release mechanics for rapid disassembly and efficient decontamination.
  • Rear-Mounted Electromagnetic Force Sensor: Premium-tier high-accuracy internal balance core ensures outstanding repeatability, stable readings, and fast response kinetics.
  • Extendable & Adjusting LED Display Panel: Features an ultra-bright layout that allows operators to seamlessly adjust the display tilt angle for zero-parallax reading verification.
  • Versatile Operational Weighing Modes: Supports robust native processing for standard foundational weight measurement, percentage balance determination, and precise parts tracking/piece counting workflows.
  • Instantaneous Multi-Unit Conversions: Enables single-key toggle transitions between international mass dimensions including grams (g), carats (ct), ounces (oz), and pounds (lb) with zero manual math.
  • Optimized Trace Micro-Addition Processing: Driven by advanced digital signal processing firmware, the system maintains rock-solid readouts with zero baseline drift, micro-capturing minute sample additions with high fidelity.
  • Integrated RS232 Communication Bus: Bidirectional port supports direct data pipelines to micro-printers and host computer terminals, enabling automated data logging and paperless compliance tracking.
  • Autonomous Fully Automatic isbl Calibration: Executes automated internal balancing calibration if ambient workspace temperature fluctuates by ≥1.5°C or if time elapsed exceeds 2 hours. Supports manual override.

APPLICATION SCOPE: High-accuracy industrial laboratory analysis, analytical chemistry, premium material research, and dual-range core verification workflows.
HIGH-EFFICIENCY HARNESS: Cost-effective design architectures highly optimized for analytical research institutes and institutional compliance laboratories.
IMPORTANT NOTICE: To preserve uncompromised reading precision and maintain sensor linearity, allow an initial warm-up threshold of 30-60 minutes following power engagement before performing operational zeroing, internal calibration, or sample addition.
TAILORED INDUSTRIAL LAB SOLUTIONS
Contact our elite laboratory engineering team for institutional bulk procurement quotes or interface custom integration.
EMAIL: INQUIRY@ATOMFAIR.COM
MANUFACTURER OPERATIONS: ATOMFAIR LLC INSTRUMENTS DIVISION
REGISTERED BRAND: ATOMFAIR®

The balance requires a controlled environment with temperature between 10°C and 33°C and relative humidity between 20% and 80%. A mandatory preheating period of 30 to 60 minutes after power-on is required before performing zeroing, calibration, or sample addition.

  • Preheating Requirement: Allow the balance to warm up for 30 to 60 minutes following power-on to stabilize the electromagnetic force sensor before any measurement operations.
  • Environmental Stability: Maintain ambient temperature within 10°C to 33°C and humidity within 20% to 80% RH to ensure specified linearity and repeatability.
  • Calibration Trigger: The internal isbl calibration executes automatically when ambient temperature fluctuates by ≥1.5°C or when elapsed time exceeds 2 hours, but manual override is supported.
  • Stabilization Time: Allow a stabilization response time of ≤5 seconds after placing a sample before recording the measurement.
  • Power Supply: Use the provided 220V AC / 50Hz input, 12V DC / 2A output power adapter to avoid electrical instability.

Follow these steps after powering on the balance to obtain accurate weight measurements. The procedure includes preheating, zeroing, calibration, and sample addition.

Required Equipment: ATOMFAIR EB51G-01MG-R-02 analytical balance

  1. Preheat the balance
    Allow the balance to warm up for 30 to 60 minutes after connecting the power supply.
  2. Zero the balance
    Perform zeroing of the balance by pressing the tare or zero key once the display stabilizes.
  3. Calibrate the balance
    Initiate the internal isbl calibration manually or wait for automatic calibration triggered by temperature or time changes.
  4. Place the sample
    Place the sample gently on the weighing pan and wait for the stabilization indicator before recording the mass.
  5. Record the measurement
    Record the displayed weight value after the stabilization time of ≤5 seconds has elapsed.
  6. Convert units if needed
    Convert the unit if needed using the single-key toggle between grams, carats, ounces, or pounds.
  7. Transfer data
    Transfer the data via the RS232 interface to a printer or computer for documentation.

How does the dual-range readability (0.01 mg vs 0.1 mg) affect measurement accuracy and capacity on the EB51G-01MG-R-02?

The balance offers two readability modes: 0.01 mg for high-precision measurements up to 51 g, and 0.1 mg for larger samples up to 120 g. The ±0.02 mg linearity and repeatability apply to the 0.01 mg range, while the 0.1 mg range has ±0.1 mg specifications. Users should select the 0.01 mg range for analytical chemistry requiring microgram-level precision, and switch to the 0.1 mg range for semi-micro weighing of larger masses.

What are the environmental and power requirements for installing the EB51G-01MG-R-02 in a laboratory?

The balance requires an operating temperature of 10°C to 33°C and humidity between 20% and 80% RH. It uses a global matrix power interface with 220V AC / 50Hz input and 12V DC / 2A output. A 30-60 minute warm-up period after power-on is mandatory before calibration or measurement to ensure sensor linearity.

How does the internal isbl calibration system on the EB51G-01MG-R-02 maintain accuracy over time?

The balance features fully automatic internal calibration (isbl) that triggers when ambient temperature fluctuates by ≥1.5°C or when more than 2 hours have elapsed since the last calibration. Manual override is also supported. This eliminates the need for external calibration weights and ensures consistent metrological traceability in changing lab conditions.

The ATOMFAIR EB51G-01MG-R-02 is a 51g/120g dual-range analytical balance with 0.01 mg readability, featuring split-body design, automatic isbl calibration, and a glass draft shield for stable, high-precision weighing in controlled laboratory environments.

Positive

  • Dual-range readability and capacity: Provides 0.01 mg / 0.1 mg readability and 51 g / 120 g dual-range capacity, enabling high-precision micro-weighing and extended sample weighing within a single instrument.
  • Split-body architecture with automatic calibration: Detached control display isolates hand-induced vibrations, while the internal isbl calibration system automatically adjusts for ambient temperature drifts ≥1.5°C or 2-hour intervals, ensuring stable, drift-free readings.

Trade-offs

  • Mandatory 30-60 minute warm-up: A preheating period of 30–60 minutes after power-on is required before performing zeroing, calibration, or sample addition, delaying immediate use.
  • Sensitive to ambient temperature and humidity: Operating range is limited to 10°C–33°C and 20%–80% RH; deviations outside these conditions may compromise measurement accuracy and sensor linearity.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.