SpinCore M 0506 Low-Speed Centrifuge, 300-5000 rpm, step 10 rpmProduct Type: Low-Speed Centrifuge
Research-grade laboratory product
|
|||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, platform compatibility or configuration confirmation, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
The centrifuge requires confirmation of rotor, adapter, and tube compatibility prior to use. Electrical supply must be within 100-240 V, 50/60 Hz, and the method must be validated for speed, RCF, and tube format.
- Rotor Compatibility: Confirm that the rotor and adapter are compatible with the tube types and volumes used.
- Electrical Supply: Ensure the power source matches the 100-240 V, 50/60 Hz specification.
- Method Validation: Verify that the selected speed, RCF, and run time are appropriate for the sample and tube format.
- Tube Format: Use tubes that fit within the specified rotor capacity of 6 x 1.5/5/7/10/15 mL or 4 x 20/50 mL.
- Time Setting: Set the running time within the available range of 30 seconds to 99 minutes, or select HOLD for continuous operation.
How do the acceleration and deceleration profiles affect sample integrity in the SpinCore M 0506 centrifuge?
The centrifuge uses a 1-up acceleration and 2-down deceleration profile, meaning a single ramp for acceleration and two selectable deceleration ramps. This can influence pellet resuspension and separation quality—using a slower deceleration ramp helps prevent disturbance of loose pellets. The LCD display and program storage (P1/P2) allow users to set and recall these parameters for method reproducibility.
Can the SpinCore M 0506 centrifuge accommodate tube sizes beyond the listed rotor capacities?
The standard rotor capacity is 6 x 1.5/5/7/10/15 mL and 4 x 20/50 mL. For tube sizes outside these ranges, compatible adapters may be required; the manufacturer explicitly advises confirming rotor, adapter, and tube compatibility before quotation. Adapters are not included by default and must be selected based on the specific tube format and required g-force.
What are the electrical and installation requirements for the SpinCore M 0506 low-speed centrifuge?
The centrifuge operates on a universal power supply of 100–240 V, 50/60 Hz, with a power consumption of 70 W, making it suitable for global laboratories without voltage switching. It weighs 5.2 kg with dimensions of 300 x 240 x 180 mm, and the HOLD continuous operation function should be used with stable electrical grounding to ensure consistent performance and safety.
The SpinCore M 0506 low-speed centrifuge offers a 300–5000 rpm range with 10 rpm increments and a maximum RCF of 2600 × g, suitable for routine tube processing and sample separation. Its rotor accommodates multiple tube sizes from 1.5 to 50 mL, but the limited g-force and speed accuracy of ±20 rpm may constrain use in high-resolution or high-force separations.
Positive
- Precise speed and RCF control: Speed range of 300–5000 rpm and RCF up to 2600 × g, both adjustable in 10-unit increments, enabling fine-tuned method-specific centrifugation for standard tube processing workflows.
- Versatile rotor capacity: Rotor accommodates 6 × 1.5/5/7/10/15 mL tubes and 4 × 20/50 mL tubes, providing flexible tube and throughput matching for a variety of sample volumes in a single run.
Trade-offs
- Moderate maximum RCF: Maximum relative centrifugal force of 2600 × g may be insufficient for high-force applications such as subcellular fractionation, DNA precipitation, or pelleting small microbial cells.
- Limited speed accuracy and profiles: Speed accuracy of ±20 rpm and only one acceleration and two deceleration profiles may reduce reproducibility in time-sensitive protocols requiring rapid or precise ramping control.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).





