High-Temperature Stirring Furnace, 1400 °C
LABORATORY THERMAL PROCESSING EQUIPMENT
|
|||||||||||||||||||
|
|||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, configuration matching, power supply confirmation or quotation review, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
Operate the furnace with unobstructed airflow around the double air-cooled body to maintain surface temperature below 60°C. Use only crucibles and materials rated for 1400°C and ensure proper gas or vacuum connections for controlled atmosphere processing.
- Surface Temperature Limit: Ensure the double air cooling structure remains unobstructed to keep the furnace body surface temperature below 60°C during operation.
- Chamber Temperature Rating: Use only crucibles and sample materials that can withstand the maximum chamber temperature of 1400°C.
- Atmosphere Compatibility: When using vacuum or flowing-gas treatment, confirm that all connections and seals are rated for the intended gas and pressure conditions.
Follow these steps to safely initialize and operate the furnace for thermal processing. Ensure all configuration requirements are met before starting.
Required Equipment:
- Confirm Configuration
Confirm that the furnace configuration matches the intended process requirements, including temperature class, chamber size, and power supply. - Position Furnace
Place the furnace on a stable, non-flammable surface with unobstructed airflow around the double air-cooled body. - Set Temperature Profile
Set the desired temperature profile using the fuzzy PID controller with an accuracy of ±1°C. - Load Crucible
Load the crucible with sample material and position it inside the chamber, ensuring the stirrer mechanism can move freely. - Start Heating and Stirring
Activate the stirrer and begin the heating cycle, monitoring the furnace surface temperature to ensure it remains below 60°C. - Cool Down
Allow the furnace to cool naturally before opening the chamber to remove the crucible.
How does the crucible stirrer improve temperature uniformity in the BF-1400-2N 1400 °C chamber furnace?
The crucible stirrer moves up and down inside the chamber to ensure materials are heated evenly, as stated in the configuration highlights. The furnace also employs fuzzy PID control with a temperature control accuracy of ±1 °C, which together with the mechanical stirring provides uniform thermal treatment for calcination, sintering, and annealing processes.
How does the vacuum-formed alumina-fiber insulation reduce energy consumption in the 1400 °C stirring furnace?
The furnace uses vacuum-formed alumina-fiber inorganic insulation along with other heat insulating materials, resulting in electric consumption of only 25% of the same type furnace consumption, as noted in the configuration highlights. This insulation also provides thermal efficiency and energy-saving operation, making the furnace smaller and more efficient.
What is the surface temperature safety feature of the BF-1400-2N 1400 °C stirring furnace?
The furnace body is double air cooling structure that controls the furnace surface temperature to no more than 60 °C when the furnace is heated to its maximum temperature of 1400 °C, as specified in the configuration highlights. This ensures safe operation and prevents burn hazards during high-temperature processing.
The Atomfair BF-1400-2N is a 1400°C chamber furnace with vacuum-formed alumina-fiber insulation for energy efficiency and a crucible stirrer for uniform heating, but requires custom specification of process size, gas/vacuum, and power supply.
Positive
- Energy-efficient insulation: Vacuum-formed alumina-fiber inorganic insulation reduces electric consumption to 25% of typical furnaces, lowering operational costs.
- Integrated crucible stirrer: The internal stirrer ensures uniform heating of materials and simplifies feeding and discharging via vertical movement.
Trade-offs
- Requires pre-order configuration: Temperature class, process size, gas/vacuum package, and power supply must be confirmed before quotation, adding procurement lead time.
- Gas/vacuum system not standard: Controlled atmosphere or vacuum treatment requires a separately specified package, increasing initial setup complexity.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).