High-Temperature Box Furnace, 1700 °C, 36 L
LABORATORY THERMAL PROCESSING EQUIPMENT
|
|||||||||||||||||||
|
|||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, configuration matching, power supply confirmation or quotation review, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
The furnace surface temperature must not exceed 60 °C during maximum temperature operation due to the double air cooling structure. Vacuum-formed alumina-fiber inorganic insulation requires careful handling to prevent mechanical damage or moisture absorption that could compromise thermal efficiency.
- Surface Temperature Limit: The double air cooling structure controls furnace surface temperature to no more than 60 °C when the furnace is heated to maximum temperature.
- Insulation Integrity: The vacuum-formed alumina-fiber inorganic insulation must be protected from physical impact and moisture to maintain thermal efficiency and energy-saving performance.
Confirm temperature class, usable process size, gas/vacuum package, power supply, and accessory configuration before operation. Ensure the furnace is placed on a stable, non-flammable surface with adequate ventilation for the double air cooling system.
Required Equipment: Personal protective equipment (heat-resistant gloves, safety glasses), Power supply matching rated voltage (AC 220V 50/60Hz, 9KW)
- Verify Configuration
Confirm the temperature class, usable process size, gas/vacuum package, power supply, and required accessories match the intended application before proceeding. - Inspect Furnace
Inspect the furnace body and insulation for any visible damage or moisture contamination prior to first use. - Connect Power Supply
Connect the furnace to a dedicated AC 220V 50/60Hz power outlet rated for at least 9KW with proper grounding. - Set Temperature Program
Set the desired heating ramp rate and target temperature according to the material processing requirements, ensuring the furnace is empty during initial ramp-up. - Monitor Surface Temperature
Monitor the furnace surface temperature during operation to confirm it remains below 60 °C as specified by the double air cooling design. - Allow Cool Down
Allow the furnace to cool down naturally to below 100 °C before opening the chamber door to avoid thermal shock to the insulation.
How does the BF-1700-2X achieve a 75% reduction in energy consumption compared to conventional high-temperature furnaces?
The furnace uses vacuum-formed alumina-fiber inorganic insulation, which offers high thermal efficiency. The product description states that electric consumption is only 25% of the same type furnace consumption, resulting in a 75% savings. Additionally, the double air cooling structure reduces heat loss.
What are the electrical requirements for installing the Atomfair BF-1700-2X box furnace?
The furnace is rated at 9KW power and requires AC 220V, 50/60Hz supply. The product description notes that the user must confirm the power supply configuration before quotation, indicating that alternative voltage options may be available upon request.
How does the double air cooling structure keep the furnace surface safe during 1700°C operation?
The furnace body incorporates a double air cooling structure that maintains the exterior surface temperature at no more than 60°C even when the furnace is heated to its maximum temperature of 1700°C. This is explicitly stated in the product specifications and enhances operator safety.
This 1700°C box furnace uses vacuum-formed alumina-fiber insulation for thermal efficiency and energy savings (25% of comparable furnaces), with a double air cooling structure limiting surface temperature to 60°C at maximum operating temperature. It requires a 220V/9KW power supply and pre-order confirmation of temperature class, chamber size, gas/vacuum package, and accessories.
Positive
- Energy-efficient alumina-fiber insulation: Vacuum-formed alumina-fiber inorganic insulation reduces energy consumption to 25% of comparable furnace types, lowering operational costs.
- Safe surface temperature at max heat: Double air cooling structure keeps the furnace exterior below 60°C even when the interior reaches 1700°C, improving lab safety and reducing heat load.
Trade-offs
- Specific power infrastructure required: Rated at 9KW (220V AC, 50/60Hz), this furnace may require dedicated electrical supply and transformer for labs with different voltage standards.
- Pre-order configuration mandatory: Temperature class, chamber size, gas/vacuum package, power supply, and accessories must be confirmed before quotation, preventing immediate off-the-shelf deployment.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).