|
High-Temperature Box Furnace, 1700 °C, 18.7 L
LABORATORY THERMAL PROCESSING EQUIPMENT
|
|||||||||||||||||||
|
|||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, configuration matching, power supply confirmation or quotation review, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
The furnace surface temperature must not exceed 60 °C during maximum temperature operation due to the double air cooling structure. Vacuum-formed alumina-fiber inorganic insulation requires careful handling to prevent mechanical damage that could compromise thermal efficiency.
- Surface Temperature Limit: The double air cooling structure controls furnace surface temperature to no more than 60 °C when the furnace is heated to maximum temperature.
- Insulation Integrity: The vacuum-formed alumina-fiber inorganic insulation must remain intact to maintain thermal efficiency and prevent energy loss.
This procedure covers initial setup and safe operation of the 1700 °C box furnace for calcination, sintering, or annealing. Proper power supply confirmation and temperature class verification are required before use.
Required Equipment: High-Temperature Box Furnace BF-1700-2W, AC 220V 50/60Hz power supply rated at 9KW
- Confirm Power Supply
Verify the available power supply matches the required AC 220V 50/60Hz at 9KW before connecting the furnace. - Inspect Insulation and Cooling System
Inspect the vacuum-formed alumina-fiber insulation for cracks or damage and confirm the double air cooling structure is unobstructed. - Set Temperature Class
Set the furnace to the desired temperature class within the 1700 °C maximum, ensuring the process size and heating zone layout are appropriate for the sample. - Load Sample and Start Heating
Place the sample inside the chamber, close the door securely, and initiate the heating program for calcination, sintering, or annealing. - Monitor Surface Temperature
Monitor the furnace surface temperature during operation to ensure it remains below 60 °C, adjusting airflow if necessary. - Allow Cool Down Before Unloading
Allow the furnace to cool down to a safe handling temperature before opening the door and removing the sample.
How does the double air cooling structure affect furnace surface temperature at maximum operating temperature?
The double air cooling structure limits furnace surface temperature to no more than 60°C even when the furnace is heated to its maximum temperature of 1700°C, as stated in the configuration highlights. This enables safe operation and reduces heat loss to the environment.
What type of insulation material is used in the BF-1700-2W and how does it contribute to energy efficiency?
The furnace uses vacuum-formed alumina-fiber inorganic insulation, which provides thermal efficiency and energy-saving operation. According to the specifications, this insulation reduces electric consumption to only 25% of that of conventional furnaces of the same type, making it highly energy-efficient for high-temperature processes.
What are the power supply requirements for this 1700°C box furnace?
The furnace is rated at 9KW and requires AC 220V, 50/60Hz power supply. The product description emphasizes that users must confirm power supply configuration before quotation, indicating that proper electrical infrastructure is critical for safe and reliable operation.
This high-temperature box furnace rated for 1700°C with 18.7L chamber uses vacuum-formed alumina-fiber insulation for thermal efficiency and double air cooling to maintain a safe surface temperature. Its energy consumption is reportedly 25% of comparable models, but it requires a specific 220V/9KW supply and pre-order configuration confirmation.
Positive
- Vacuum-formed alumina-fiber insulation: Vacuum-formed alumina-fiber inorganic insulation provides thermal efficiency and energy-saving operation, reducing heat loss during high-temperature processes.
- Double air cooling structure: Double air cooling ensures furnace surface temperature remains below 60°C even at maximum operating temperature, improving lab safety and reducing ambient heat load.
Trade-offs
- Specific power supply required: The furnace operates at 220V AC, 50/60Hz, 9KW, which may require dedicated electrical infrastructure and is not compatible with standard 110V lab outlets.
- Pre-order configuration confirmation required: Temperature class, usable process size, gas/vacuum package, and accessory configuration must be confirmed before quotation, adding a step to procurement and potentially delaying delivery.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).






