High-Temperature Box Furnace 1700 °C 12 L

$8,900.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

1700 °C, 12 L high-temperature box furnace with 9 kW power and AC 220 V, 50/60 Hz alumina-fiber insulation for calcination, sintering and annealing.

SKU: AF-BF-B-1700-L6VF-002V
Category:
Brands:

High-Temperature Box Furnace, 1700 °C, 12 L
LABORATORY THERMAL PROCESSING EQUIPMENT
Product Overview

High-Temperature Box Furnace, 1700 °C, 12 L is a high-temperature chamber furnace for calcination, sintering, annealing, heat treatment and high-temperature material preparation.

The configuration focuses on Uses vacuum-formed alumina-fiber inorganic insulation for thermal efficiency and energy-saving operation.

Additional configuration points include Furnace body is double air cooling structure to control furnace surface temperature no more than 60 °C when furnace is heated into max. temperature.

Technical Specifications
Parameter Specification / Available Values
Atomfair Model BF-1700-2V
Product Family high-temperature chamber furnace
Configuration Focus Uses vacuum-formed alumina-fiber inorganic insulation for thermal efficiency and energy-saving operation.
Process Fit calcination, sintering, annealing, heat treatment and high-temperature material preparation
Quotation Confirmation Confirm temperature class, tube or chamber size, heating-zone layout, gas/vacuum package, power supply and required accessories.
Configuration Highlights
  • Uses vacuum-formed alumina-fiber inorganic insulation for thermal efficiency and energy-saving operation.
  • Furnace body is double air cooling structure to control furnace surface temperature no more than 60 °C when furnace is heated into max. temperature.
  • Made of various heat insulating materials to make furnace smaller and energy consumption less(electric consumption is only 25% of the same type furnace consumption).
  • Power rated: 9KW (220V).
  • Voltage rated: AC 220V 50/60Hz.
APPLICATION SCOPE: calcination, sintering, annealing, heat treatment and high-temperature material preparation.
PACKAGING: The equipment is prepared with protective inner materials and reinforced outer packaging for handling, storage and delivery.
IMPORTANT NOTICE: Please confirm temperature class, usable process size, gas/vacuum package, power supply and accessory configuration before quotation.
LABORATORY PROCUREMENT SUPPORT
For model selection, configuration matching, power supply confirmation or quotation review, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

The furnace surface temperature must not exceed 60 °C during maximum temperature operation due to the double air cooling structure. Vacuum-formed alumina-fiber insulation requires careful handling to prevent mechanical damage that could compromise thermal efficiency.

  • Surface Temperature Limit: The double air cooling structure controls furnace surface temperature to no more than 60 °C when the furnace is heated to maximum temperature.
  • Insulation Integrity: The vacuum-formed alumina-fiber inorganic insulation must remain intact to maintain thermal efficiency and energy-saving performance.

Confirm temperature class, usable process size, gas/vacuum package, power supply, and accessory configuration before operation. Ensure the furnace is placed on a stable, non-flammable surface with adequate ventilation.

Required Equipment: AC 220V 50/60Hz power supply rated at 9KW, Protective inner packaging materials for handling

  1. Verify Power Supply
    Confirm the available power supply matches the required AC 220V 50/60Hz at 9KW rating before connecting the furnace.
  2. Inspect Insulation
    Inspect the vacuum-formed alumina-fiber insulation for any cracks or damage that could reduce thermal efficiency or cause uneven heating.
  3. Set Temperature Program
    Program the furnace controller with the desired heating ramp rate, target temperature up to 1700 °C, and hold time for the specific calcination, sintering, or annealing process.
  4. Monitor Surface Temperature
    Monitor the furnace surface temperature during operation to ensure it does not exceed 60 °C, indicating proper function of the double air cooling system.
  5. Allow Cool Down
    Allow the furnace to cool completely to room temperature before opening the chamber door to prevent thermal shock and operator injury.

How does the energy consumption of the 1700°C box furnace compare to conventional furnaces of the same type?

The furnace consumes only 25% of the energy of a typical same-type furnace, thanks to its vacuum-formed alumina-fiber inorganic insulation and optimized design, as stated in the configuration highlights. This reduces operating costs and improves thermal efficiency for high-temperature processes like sintering and annealing.

Does the 1700°C box furnace come with integrated gas or vacuum capability?

The furnace does not include integrated gas or vacuum capability as standard; the required gas/vacuum package must be confirmed before quotation, per the important notice. The user should specify the exact package needed for their intended calcination or heat treatment process.

What is the maximum surface temperature of the furnace during operation at 1700°C?

The furnace body uses a double air cooling structure that limits the surface temperature to no more than 60°C even when the furnace is heated to its maximum temperature of 1700°C, ensuring safe handling and laboratory operation.

High-temperature box furnace (1700°C, 12L) utilizing vacuum-formed alumina-fiber insulation for energy efficiency, with double air cooling to maintain surface temperature below 60°C. Requires 220V AC power and pre-purchase configuration confirmation for compatible operation.

Positive

  • Vacuum-formed alumina-fiber insulation: Uses vacuum-formed alumina-fiber inorganic insulation to improve thermal efficiency and reduce energy consumption, claimed at 25% of comparable furnaces.
  • Double air cooling for surface safety: Double air cooling structure maintains furnace surface temperature ≤60°C even at maximum operating temperature, improving lab safety and reducing heat loss.

Trade-offs

  • Specific power supply required: Requires AC 220V 50/60Hz power supply; may not be directly compatible with standard 110V or 208V lab circuits without step-up transformer or dedicated line.
  • Pre-purchase configuration confirmation: Customer must confirm temperature class, chamber size, gas/vacuum package, power supply, and accessories before quotation, indicating the furnace is not a pure off-the-shelf unit and requires specification matching.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).