High-Temperature Box Furnace, 1600 °C, 36 L
LABORATORY THERMAL PROCESSING EQUIPMENT
|
|||||||||||||||||||
|
|||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, configuration matching, power supply confirmation or quotation review, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
|||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
The furnace surface temperature must not exceed 60 °C during maximum temperature operation due to double air cooling structure. Vacuum-formed alumina-fiber inorganic insulation requires careful handling to prevent damage and maintain thermal efficiency.
- Surface Temperature Limit: Confirm that the double air cooling structure is unobstructed to maintain furnace surface temperature below 60 °C at maximum operating temperature.
- Insulation Integrity: Inspect vacuum-formed alumina-fiber insulation for cracks or degradation before each use to prevent thermal efficiency loss and potential hot spots.
This procedure covers initialization, loading, and safe shutdown of the 1600 °C box furnace for calcination or sintering. Proper ventilation and personal protective equipment are required throughout operation.
Required Equipment: High-temperature gloves, Tongs or crucible handling tool, Personal protective equipment (safety glasses, lab coat)
- Pre-Operation Inspection
Inspect the furnace chamber for debris, cracks in insulation, and ensure the double air cooling vents are unobstructed. - Set Temperature Program
Program the controller with the desired ramp rate, target temperature (up to 1600 °C), and hold time for the specific calcination or sintering process. - Load Sample
Place the sample in a suitable crucible using tongs and high-temperature gloves, then position it centrally in the chamber. - Start Heating Cycle
Close the furnace door securely and initiate the programmed heating cycle, monitoring the temperature display for proper ramp progression. - Monitor During Operation
Verify that the furnace surface temperature remains below 60 °C and that no unusual odors or smoke are emitted during the cycle. - Cool Down and Unload
Allow the furnace to cool to below 200 °C before opening the door, then use tongs and high-temperature gloves to remove the crucible. - Post-Operation Shutdown
Turn off the main power switch and confirm the furnace has returned to ambient temperature before closing the chamber for storage.
How does the vacuum-formed alumina-fiber insulation reduce energy consumption compared to conventional furnaces?
The BF-1600-2S uses vacuum-formed alumina-fiber inorganic insulation, which provides high thermal efficiency and reduces energy consumption to only 25% of comparable furnaces. This is further supported by the double air cooling structure that maintains the furnace surface temperature at ≤60°C even at 1600°C, minimizing heat loss to the environment.
What are the electrical infrastructure requirements for the BF-1600-2S box furnace?
The furnace requires a 208-240V AC power supply, 50/60Hz, with a rated power of 9KW. Users must confirm the available power supply and voltage compatibility with the technical sales team before quotation to ensure proper installation and operation.
What surface temperature does the furnace reach during operation at 1600°C, and how is it controlled?
The double air cooling structure of the furnace body ensures the external surface temperature does not exceed 60°C even when the chamber is at its maximum temperature of 1600°C. This is achieved by forced air circulation between the inner and outer walls, enhancing laboratory safety and reducing heat-related hazards.
The Atomfair BF-1600-2S is a 1600°C box furnace with a 36L chamber, utilizing vacuum-formed alumina-fiber inorganic insulation for thermal efficiency and energy savings, but requires confirmation of temperature class, chamber size, and power supply before ordering due to its configurable nature.
Positive
- Alumina-fiber insulation for efficiency: Uses vacuum-formed alumina-fiber inorganic insulation to reduce heat loss, enabling energy-saving operation with electric consumption only 25% of comparable furnaces.
- Double air cooling for safe operation: Double air cooling structure maintains furnace surface temperature at or below 60°C even during operation at maximum temperature, improving lab safety and reducing heat load.
Trade-offs
- Configuration must be confirmed before use: Temperature class, usable process size (chamber dimensions), gas/vacuum package, and power supply (208-240V, 50/60Hz, 9kW) must be specified during ordering; unspecified options may affect fit and performance.
- Not standalone; requires infrastructure: High power rating (9kW) necessitates appropriate electrical supply and lab infrastructure; the furnace is not pre-configured for gas or vacuum without explicit package selection.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.