ATOMFAIR® EB210G-0.1MG-R-07 DUAL-RANGE ELECTROMAGNETIC ANALYTICAL BALANCEEXTERNAL CALIBRATION
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
TAILORED SOLUTIONS FOR RESEARCH
Contact our engineering team for technical support or official institutional quotations.
EMAIL: inquiry@atomfair.com
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
This analytical balance requires a 30-minute pre-heating phase to stabilize the electromagnetic force compensation sensor before calibration. The draft shield must be fully sealed when performing semi-micro weighing at 0.01 mg readability to avoid air currents.
- Pre-heating Requirement: Allow a 30-minute system pre-heating phase to let the electromagnetic core reach full equilibrium prior to initializing calibration sequences.
- Draft Shield Sealing: Ensure the three-door draft shield housing is entirely sealed for hundred-thousandth semi-micro weighing verification routines at 0.01 mg readability.
- Leveling Procedure: Use the front-facing bubble spirit level indicator and heavy-duty micro-threaded leveling feet to achieve proper environmental alignment.
- External Calibration Protocol: Follow the manual external calibration protocol to guarantee predictable user-verified linearity points.
These steps ensure the balance reaches thermal equilibrium and is properly leveled for accurate external calibration. The draft shield must be sealed during high-precision measurements to minimize air current interference.
Required Equipment: Bubble spirit level indicator, Micro-threaded leveling feet, Certified external calibration weight
- Level the balance
Position the balance on a stable surface and adjust the leveling feet until the bubble spirit indicator is centered. - Power on and preheat
Power on the balance and allow a 30-minute pre-heating phase for the electromagnetic core to reach full equilibrium. - Seal the draft shield
Close all three doors of the draft shield housing to ensure an isolated ambient chamber before weighing. - Perform external calibration
Execute manual external calibration using a certified weight to verify linearity and repeatability within specified tolerance.
What are the dual-range capacity and readability specifications of the EB210G-0.1MG-R-07 analytical balance?
The EB210G-0.1MG-R-07 offers a dual-range matrix: maximum capacity of 210 g with 0.1 mg readability, and 120 g with 0.01 mg readability. Repeatability is ±0.6 mg for the 210 g range and ±0.06 mg for the 120 g range, with linearity matching those values.
Does the EB210G-0.1MG-R-07 use internal or external calibration?
The EB210G-0.1MG-R-07 uses external calibration. It is part of the FB series, which employs manual external calibration protocols, as opposed to the FA series with automated internal calibration. This allows user-verified linearity points during routine verification.
What preparation is required before using the EB210G-0.1MG-R-07 at 0.01 mg readability?
For semi-micro weighing at 0.01 mg, ensure the three-door glass draft shield is fully sealed and allow a 30-minute system pre-heating phase for the electromagnetic core to reach equilibrium before initiating calibration sequences.
The ATOMFAIR® EB210G-0.1MG-R-07 is a dual-range electromagnetic analytical balance offering 210 g / 120 g capacity with 0.1 mg / 0.01 mg readability, using a rear-mounted EMFC sensor and external calibration. Its glass draft shield and RS232 interface support stable weighing and data logging, but the 0.01 mg readability requires a 30-minute pre-heating phase and sealed draft shield for accurate operation.
Positive
- Dual-range capacity and readability: Provides 210 g / 120 g maximum capacity with 0.1 mg / 0.01 mg readability, enabling precise weighing of both larger and micro-scale samples on a single instrument.
- Rear-mounted EMFC sensor stability: High-sensitivity, ultra-stable rear-mounted electromagnetic force compensation sensor maximizes structural resolution limits for consistent measurement performance.
Trade-offs
- External calibration requirement: Uses manual external calibration protocols, requiring user intervention to verify linearity points, unlike automated internal calibration in companion FA series.
- Pre-heating and sealing needed for 0.01 mg: For 0.01 mg readability, the draft shield must be fully sealed and a 30-minute system pre-heating phase is required to reach electromagnetic core equilibrium before calibration.