ATOMFAIR® EB100G-0.01G-03 LABORATORY PRECISION ELECTRONIC BALANCESCI-GRADE MEASUREMENT SYSTEM
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
This balance requires a stable, vibration-free environment with the draft shield deployed to maintain measurement accuracy. The device must be placed on a level surface and shielded from indoor airflow to prevent micro-mass strain errors.
- Environmental Requirements: Operate the balance on a level, stable workbench free from vibrations and air currents to ensure repeatable measurements.
- Draft Shield Deployment: Always use the factory-installed glass draft shield during weighing to isolate the sensor from environmental airflow disruptions.
How does the ±0.01 g repeatability of the EB100G-0.01G-03 balance impact the reliability of piece counting for small components?
The ±0.01 g repeatability ensures that successive measurements of the same mass are consistent within 0.01 g, which is critical for accurate piece counting when individual part weights are close to the readability limit. The balance's embedded piece counting software uses this precision to calculate part counts reliably, as stated in the product's core specifications and counting functionality.
What data interface options are available for exporting measurement data from the EB100G-0.01G-03 to external systems?
The balance is equipped with a standard RS232 communication interface that supports high-speed serial telemetry data export to PCs or data loggers. No other interface types are specified in the product description.
Does the EB100G-0.01G-03 require a dedicated power outlet, or can it operate on battery power for field use?
The balance features a dual AC/DC hybrid supply, allowing it to operate from either mains power or DC battery power, enabling reliable testing independent of strict building outlet connectivity. This makes it suitable for field or mobile laboratory environments as described in the core features.
The ATOMFAIR EB100G-0.01G-03 is a precision balance optimized for piece counting workflows with 100 g capacity and 0.01 g readability, featuring an integrated glass draft shield and dual AC/DC power supply for stable operation in varied laboratory settings.
Positive
- Integrated Draft Shield for Airflow Isolation: The factory-installed glass draft shield isolates the weighing sensor from indoor airflow disruptions, supporting stable measurements in standard lab environments.
- Dual AC/DC Power Supply for Flexible Deployment: Adaptive power framework permits reliable testing runs independent of strict building outlet connectivity, enabling operation in field or remote settings.
Trade-offs
- Requires Draft Shield for Micro-Mass Stability: The compliance notice states that the YP-N precision series requires draft shield deployment to control micro-mass strain, meaning the balance's accuracy is sensitive to airflow without the shield.
- Requires Balanced Baseline Environment: A completely balanced baseline environment is required to achieve specified repeatability and linearity, necessitating careful leveling and vibration-free placement.