EB210G-0.1mg/0.01mg Dual-Range Analytical Balance ATOMFAIR®

$2,534.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Research-grade dual-range EMFC analytical balance with 210g/52g capacity, 0.1mg/0.01mg readability, external calibration, Φ90 mm pan. Order now.

SKU: AF-EI-B-SMBL-NS0U-IR16
Category:
Tags:
Brands:

ATOMFAIR® EB210G-0.1MG-R-01 DUAL-RANGE ELECTROMAGNETIC ANALYTICAL BALANCE

RESEARCH GRADE

Product Overview

The ATOMFAIR® EB210G-0.1MG-R-01 is a research-grade dual-range electromagnetic analytical balance with external calibration, purpose-built for high-precision laboratory analysis and metrology verification workflows. It adopts a dual-range dual-readability architecture: within the 52g semi-micro precision range, it achieves 0.01mg readability with ±0.06mg repeatability and ±0.06mg linearity for ultra-trace sample testing; within the 210g extended analytical range, it delivers 0.1mg readability with ±0.6mg repeatability and ±0.6mg linearity to accommodate routine weighing with sample vessels.
Powered by state-of-the-art rear-mounted electromagnetic force compensation (EMFC) technology, it effectively mitigates subtle ambient drift and maintains stable baseline performance even during long-duration testing. Its spacious three-door glass draft shield isolates airflow interference, while the high-contrast backlit LCD panel with adjustable brightness ensures fatigue-free reading across different operating environments. With standard RS232 connectivity, versatile built-in weighing modes and under-hook weighing compatibility, it is an ideal choice for analytical chemistry research, trace powder analysis, material characterization and institutional metrology compliance.

Technical Specifications

EB210G-0.1MG-R-01 EXCLUSIVE PARAMETER SPECIFICATION DETAILS
Model Designation EB210G-0.1MG-R-01
Maximum Capacity Range (g) 210 g / 52 g (Dual-Range Matrix)
Readability Metrics (mg) 0.1 mg / 0.01 mg (Dual-Readability Matrix)
Repeatability Bounds (mg) ±0.6 mg / 0.06 mg
Linearity Deviation (mg) ±0.6 mg / 0.06 mg
Weighing Pan Dimensions (mm) Φ90 mm


FA/FB Series Combined Matrix Specifications

Parameter Model EB210G-0.1MG-D EB210G-0.1MG-R-01 EB210G-0.1MG-R-02 EB210G-0.1MG-R-03 EB210G-0.1MG-R-04 EB210G-0.1MG-R-05 EB210G-0.1MG-R-06 EB210G-0.1MG-R-07
Max Capacity (g) 210 / 32 210 / 52 210 / 82 210 / 120 210 / 32 210 / 52 210 / 82 210 / 120
Readability (mg) 0.1 / 0.01 0.1 / 0.01 0.1 / 0.01 0.1 / 0.01 0.1 / 0.01 0.1 / 0.01 0.1 / 0.01 0.1 / 0.01
Repeatability (mg) ±0.6 / 0.06 ±0.6 / 0.06 ±0.6 / 0.06 ±0.6 / 0.06 ±0.6 / 0.06 ±0.6 / 0.06 ±0.6 / 0.06 ±0.6 / 0.06
Linearity (mg) ±0.6 / 0.06 ±0.6 / 0.06 ±0.6 / 0.06 ±0.6 / 0.06 ±0.6 / 0.06 ±0.6 / 0.06 ±0.6 / 0.06 ±0.6 / 0.06
Pan Size (mm) Φ90 Φ90 Φ90 Φ90 Φ90 Φ90 Φ90 Φ90
Calibration Variant FA Series: Fully Automated Built-In One-Key Internal Calibration (Timer & Temperature Triggered). FB Series: Standard Configuration External Calibration Framework.


Key Features & Technical Innovations

  • Rear-Mounted EMFC Matrix: Utilizes high-sensitivity, ultra-stable rear-mounted electromagnetic force compensation sensor technology to maximize structural resolution limits.
  • Automated Internal Self-Calibration: FA variants deliver one-key fully automated internal calibration triggered by timed schedule intervals or active ambient temperature fluctuations, neutralizing mechanical measurement errors without standard weights handling.
  • Volumetric Draft Shield Housing: Framed within a large, spacious three-door glass draft shield, granting unrestricted physical loading maneuvers inside an isolated ambient chamber.
  • Dual-Visual Ergonomic Panel: Toggleable background display modes between intense bright and low-light operations, preventing optical strain during extended verification sequences.
  • Multi-Unit Metric Adaptability: Factory-loaded with quick conversion routines supporting Grams (g), Carats (ct), Ounces (oz), precise parts counting, and dry-mass percentage weighing modalities.
  • Comprehensive Guard Systems: Pre-programmed with integrated overload / underload acoustic warnings, structural temperature compensation matrices, and full-range digital taring thresholds.
  • Under-Hook Density Support: Ready for dual-purpose gravimetric configurations, supporting bottom-hook weighing accessories and standard hydrostatic test stands.
  • High-Fidelity Communication Bus: Furnished with a standard RS232 digital output interface to drive automated computer logging loops or peripheral direct lab report printing.

VISUAL HARDWARE: Outfitted with an oversized high-contrast back-lit LCD visual display panel with manual illumination control switches.
ENVIRONMENTAL ALIGNMENT: Outfitted with a front-facing premium bubble spirit level indicator linked to heavy-duty micro-threaded leveling feet.
CRITICAL PRECISION NOTE: For hundred-thousandth semi-micro weighing verification routines (0.01mg), ensure the three-door draft shield housing is entirely sealed. Allow a 30-minute system pre-heating phase to let the electromagnetic core reach full equilibrium prior to initializing calibration sequences.
TAILORED SOLUTIONS FOR RESEARCH
Contact our engineering team for technical support or official institutional quotations.
EMAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

The balance requires a 30-minute pre-heating phase to stabilize the electromagnetic force compensation core before high-precision measurements. For 0.01mg readability, the three-door glass draft shield must be fully sealed to eliminate airflow interference.

  • Environmental Stability: Place the balance on a vibration-free, level surface and use the bubble spirit level and micro-threaded feet for precise leveling.
  • Pre-Heating Requirement: Allow the balance to warm up for 30 minutes after power-on to reach thermal equilibrium for the electromagnetic sensor.
  • Draft Shield Sealing: Ensure the three-door glass draft shield is completely closed during semi-micro (0.01mg) weighing to prevent air currents from affecting readings.
  • Calibration Protocol: Perform external calibration using certified standard weights as the FB series lacks internal calibration and the balance supports RS232 output for automated routines.
  • Overload Protection: The balance includes integrated overload and underload acoustic warnings to prevent damage from exceeding capacity limits.

Follow these steps to initialize the balance for semi-micro (0.01mg) accuracy. Ensure the environment is stable and the balance is properly leveled before proceeding.

Required Equipment: Certified external calibration weight set

  1. Level the balance
    Position the balance on a stable workstation and adjust the leveling feet until the bubble spirit indicator is centered.
  2. Pre-heat the sensor
    Power on the balance and allow it to warm up for 30 minutes to stabilize the electromagnetic sensor.
  3. Seal the draft shield
    Close the three-door glass draft shield completely to isolate the weighing chamber from ambient air currents.
  4. Perform external calibration
    Calibrate the balance using the appropriate certified weight set for the desired range via the external calibration function.
  5. Weigh the sample
    Place the sample on the pan and allow the reading to stabilize before recording the mass.

How does the dual-range readability of the EB210G-0.1MG-R-01 affect measurement accuracy for different sample sizes?

The balance operates in two distinct ranges: a 52 g semi-micro range with 0.01 mg readability, ±0.06 mg repeatability, and ±0.06 mg linearity for ultra-trace samples, and a 210 g analytical range with 0.1 mg readability, ±0.6 mg repeatability, and ±0.6 mg linearity for routine weighing with vessels. This dual-range architecture allows the user to select the appropriate sensitivity based on sample mass, optimizing accuracy without requiring a separate instrument.

Does the EB210G-0.1MG-R-01 support internal calibration or external calibration?

This model is part of the FB series, which uses a standard external calibration framework. Unlike the FA series that features fully automated internal calibration triggered by timer or temperature changes, the EB210G-0.1MG-R-01 requires manual external calibration using standard weights. This design is suitable for laboratories that prefer to verify calibration with their own certified mass standards.

What environmental and operational steps are required to achieve 0.01 mg readability on the EB210G-0.1MG-R-01?

To reach the 0.01 mg semi-micro precision, the three-door glass draft shield must be completely sealed to isolate airflow interference. Additionally, a 30-minute system pre-heating phase is required before initiating calibration sequences to allow the electromagnetic core to reach full thermal equilibrium. The balance also features a front bubble spirit level and micro-threaded leveling feet for proper environmental alignment.

The Atomfair EB210G-0.1MG-R-01 is a dual-range electromagnetic analytical balance offering 52 g semi-micro range at 0.01 mg readability and 210 g analytical range at 0.1 mg readability, with rear-mounted EMFC and external calibration. It is suitable for high-precision weighing but requires ambient temperature stabilization and external calibration for optimal performance.

Positive

  • Dual-range dual-readability architecture: Provides 52 g semi-micro range at 0.01 mg readability for ultra-trace samples and 210 g analytical range at 0.1 mg readability for routine weighing, enabling flexibility across different precision requirements within a single instrument.
  • Rear-mounted EMFC sensor technology: Rear-mounted electromagnetic force compensation minimizes ambient drift and maintains baseline stability during extended testing, critical for reproducible long-duration metrology.

Trade-offs

  • External calibration required: This FB-series variant uses external calibration rather than automated internal calibration, requiring manual standard weight handling and periodic user intervention to maintain accuracy.
  • 30-minute warm-up for semi-micro precision: To achieve 0.01 mg readability, the draft shield must be sealed and the balance must be pre-heated for 30 minutes to reach thermal equilibrium, delaying immediate use after power-on.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).