Electronic Analytical Balance Class I 120g 0.1mg ATOMFAIR®

$528.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Class I analytical balance with 120 g capacity, 0.1 mg readability, ±0.2 mg repeatability, isoCAL internal calibration, and RS232. Order now.

SKU: AF-EI-B-ANLB-120A-IR03
Category:
Tags:
Brands:

ATOMFAIR® EB120G-0.1MG-I-03 ELECTRONIC ANALYTICAL BALANCE

CLASS Ⅰ PRECISION METROLOGY

Product Overview

The ATOMFAIR® EB120G-0.1MG-I-03 is a high-performance analytical balance configured for Premium laboratory metrology, micro-powder analysis, with 120 g maximum capacity and 0.1 mg readability. It delivers ±0.2 mg repeatability, isoCAL fully automatic internal calibration.
Built with an electromagnetic force restoration sensor, it supports precision weighing control for the stated measurement range. Its calibration configuration is isoCAL fully automatic internal calibration, supporting the calibration workflow for this model. The weighing hardware information includes 210 mm internal weighing chamber.
The communication configuration includes a standard RS232 communication interface. The stated application scope covers Premium laboratory metrology, micro-powder analysis, dual-density evaluation.

EB120G-0.1MG-I-03 Detailed Technical Parameters

PARAMETER ITEM UNIT TECHNICAL SPECIFICATION DETAILS
Product Model EB120G-0.1MG-I-03
Product Classification Electronic Analytical Balance
Readability (d) mg 0.1
Maximum Capacity (Max) g 120
Typical Repeatability Error mg ±0.2
Typical Linearity Error mg ±0.2
Average Response Time s ≤2.5
Initial Warm-up Duration min 30~60
Accuracy Class Class Ⅰ
Physical Dimensions (L × W × H) mm 210 × 310 × 315
Weighing Pan Dimensions mm Φ90
Chamber Internal Height mm 210
Operating Ambient Temp °C 18~23
Operating Ambient Humidity 20%~80% RH (Non-condensing Matrix)
Power Supply Configuration Input: 220V AC / 50Hz; Output: 12V/2A
Communication Baud Rate 300, 600, 1200, 2400, 4800, 9600

ES-J Series Comprehensive Model Parameter Family

PARAMETER ITEM UNIT EB120G-0.1MG-I-02 EB220G-0.1MG-I-03 EB120G-0.1MG-I-03 EB220G-0.1MG-I-04
Readability (d) mg 0.1 0.1 0.1 0.1
Maximum Capacity (Max) g 120 220 120 220
Typical Repeatability Error mg ±0.2 ±0.2 ±0.2 ±0.2
Typical Linearity Error mg ±0.2 ±0.2 ±0.2 ±0.2
Average Response Time s ≤2.5
Initial Warm-up Duration min 30~60
Accuracy Class Class Ⅰ
Physical Form Dimensions mm 210 × 310 × 315 (L × W × H)
Pan Size / Chamber Height mm Φ90 Spatial Platform / 210mm Internal Chamber Vertical Height
Operating Atmospheric Matrix 18~23°C Thermal Scope / 20%~80% RH Non-condensing Conditions
Power Supply Profile Input: 220V AC / 50Hz; Output: 12V/2A Stable Direct Current
Communication Interface Standard Protocol Baud Rates: 300, 600, 1200, 2400, 4800, 9600

Universal Optional Accessories Catalog

ACCESSORY DESCRIPTION COMPATIBILITY SUPPORT STATUS
Portable Micro Dot-Matrix Printer Fully Supported (Optional Configuration Link)
USB to Serial Port Adapter Cable Fully Supported (Optional Configuration Link)
Under-hook Weighing Mechanism Device Fully Supported (Optional Configuration Link)
Solid & Liquid Dual-use Density Metrology Kit Fully Supported (Optional Configuration Link)

Key Features & Core Advantages

  • Advanced isoCAL Auto-Calibration: Integrates a fully automated internal calibration alignment system (available for internal calibration specific models) executing seamless calibration loops for reliable accuracy.
  • Standardized RS232 Data Pipeline: Equipped with industrial standard RS232 interaction protocol nodes for direct PC peripheral connectivity and automatic matched printer synchronization.
  • Thermal Temperature Compensation: Built-in proprietary environmental thermal balance algorithms, eliminating background drift triggered by temperature variants to maintain validation purity.
  • Filter Membrane Weighing Mode: Specialized internal electronic filtering parameters optimized for ultra-precise mass detection regarding low-mass or trace membrane samples.
  • High-Definition Lucid LCD Screen: Minimalist and responsive operating control deck combined with deep visibility segments for quick data extraction.

APPLICATION SCOPE: Premium laboratory metrology, micro-powder analysis, dual-density evaluation, and peripheral system data logging.
PACKAGING: Shockproof industrial grade dual-layer foam protection inserts with sealed structural enclosures and customized universal adapter assemblies.
IMPORTANT NOTICE: To sustain ideal Class Ⅰ performance parameters, preheat the assembly for 30~60 minutes within the 18~23°C regulated workspace. Prevent fluid condensations inside the non-condensing 20%~80% RH atmospheric matrix during data capture loops.
TAILORED METROLOGY FOR RESEARCH
Contact our engineering team for technical support or official institutional quotations.
EMAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

This analytical balance requires a controlled laboratory environment with temperature between 18-23°C and non-condensing relative humidity of 20-80%. A 30-60 minute warm-up period is mandatory before measurements to achieve specified Class I performance.

  • Temperature Control: Maintain ambient temperature between 18°C and 23°C to ensure measurement accuracy and thermal stability.
  • Humidity Control: Keep relative humidity within 20% to 80% non-condensing to prevent condensation inside the weighing chamber.
  • Warm-Up Procedure: Allow the balance to warm up for 30 to 60 minutes after power-on before any precision weighing operations.
  • Power Supply Stability: Use the specified 220V AC/50Hz input with 12V/2A output adapter to avoid power fluctuations affecting readings.

How does the 0.1 mg readability and ±0.2 mg repeatability affect measurement reliability for micro-powder analysis?

The EB120G-0.1MG-I-03 delivers 0.1 mg readability with ±0.2 mg repeatability and linearity, ensuring high precision for micro-powder analysis. Its Class I accuracy and isoCAL fully automatic internal calibration maintain consistent performance across the 120 g capacity range.

Can the EB120G-0.1MG-I-03 be integrated with a PC or printer for data logging?

Yes, the balance includes a standard RS232 communication interface with configurable baud rates from 300 to 9600. Optional accessories such as a portable micro dot-matrix printer and a USB-to-serial adapter cable enable direct PC connectivity and automated data logging.

What are the critical environmental and warm-up requirements to achieve Class I performance?

To sustain Class I performance, preheat the balance for 30–60 minutes within an 18–23°C regulated workspace and maintain 20%–80% RH non-condensing conditions. The built-in temperature compensation algorithm mitigates drift, but these ambient parameters are essential for optimal accuracy.

The ATOMFAIR EB120G-0.1MG-I-03 is a Class I electronic analytical balance with 120 g capacity and 0.1 mg readability, featuring isoCAL automatic internal calibration and an electromagnetic force restoration sensor for precise micro-powder analysis. Its narrow operating temperature range (18-23°C) and required 30-60 minute warm-up period impose controlled laboratory conditions for optimal performance.

Positive

  • isoCAL automatic internal calibration: The balance integrates a fully automated internal calibration system that executes calibration loops without operator intervention, ensuring consistent accuracy over time.
  • High precision and readability: With 0.1 mg readability and ±0.2 mg repeatability, the balance is well-suited for micro-powder analysis and premium laboratory metrology requiring Class I accuracy.

Trade-offs

  • Extended warm-up requirement: The balance requires a 30-60 minute warm-up period within a narrow 18-23°C temperature range to achieve its specified Class I performance, limiting immediate use after power-on.
  • Environmental sensitivity constraints: Operational humidity must remain within 20-80% RH non-condensing, and the temperature must be tightly controlled, requiring a stable laboratory environment to avoid drift.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).